Fibrillation power, an alternative method of ECG spectral analysis for prediction of countershock success in a porcine model of ventricular fibrillation.

BACKGROUND: Noninvasive prediction of defibrillation success after cardiac arrest and cardiopulmonary resuscitation (CPR) may help in determining the optimal time for a countershock, and thus increase the chance for survival. METHODS: In a porcine model (n=25) of prolonged cardiac arrest, advanced cardiac life support was provided by administration of two or three doses of either vasopressin or epinephrine after 3 or 8 min of basic life support. After 4 min of ventricular fibrillation and 18 min of life support, defibrillation was attempted. The denoised power spectral density of 10 s intervals of the ventricular fibrillation electrocardiogram (ECG) was estimated from averaged and smoothed Fourier transforms. We have eliminated the spectral contribution of artifacts from manual chest compressions and provide a definition for the contribution of ventricular fibrillation to the power spectral density. This contribution is quantified and termed "fibrillation power". RESULTS: We tested fibrillation power and two established methods in their discrimination of survivors (n=16) vs. non-survivors (n=9) in the last minute before the countershock. A fibrillation power > or =79 dB predicted successful defibrillation with sensitivity, specificity, positive predictive value and negative predictive value of 98%, 98%, 99% and 97% while a mean fibrillation frequency > or =7.7 Hz was predictive with 85%, 83%, 90% and 77% and a mean amplitude > or =0.49 mV was predictive with 95%, 90%, 94% and 91%. CONCLUSIONS: We suggest that fibrillation power is an alternative source of information on the status of a fibrillating heart and that it may match the established mean frequency and amplitude analysis of ECG in predicting successful countershock during CPR.

Animals↗

The beneficial effect of basic life support on ventricular fibrillation mean frequency and coronary perfusion pressure.

BACKGROUND AND OBJECTIVE: Chest compressions before initial defibrillation attempts have been shown to increase successful defibrillation. This animal study was designed to assess whether ventricular fibrillation mean frequency after 90 s of basic life support cardiopulmonary resuscitation (CPR) may be used as an indicator of coronary perfusion and mean arterial pressure during CPR. METHODS AND RESULTS: After 4 min of ventricular fibrillation cardiac arrest in a porcine model, CPR was performed manually for 3 min. Mean ventricular fibrillation frequency and amplitude, together with coronary perfusion and mean arterial pressure were measured before initiation of chest compressions, and after 90 s and 3 min of basic life support CPR. Increases in fibrillation mean frequency correlated with increases in coronary perfusion and mean arterial pressure after both 90 s (R=0.77, P<0.0001, n=30; R=0.75, P<0.0001, n=30, respectively) and 3 min (R=0.61, P<0.001, n=30; R=0.78, P<0.0001, n=30, respectively) of basic life support CPR. Increases in fibrillation mean amplitude correlated with increases in mean arterial pressure after both 90 s (R=0.46, P<0.01; n=30) and 3 min (R=0.42, P<0.05, n=30) of CPR. Correlation between fibrillation mean amplitude and coronary perfusion pressure was not significant both at 90 s and 3 min of CPR. CONCLUSIONS: In this porcine laboratory model, 90 s and 3 min of CPR improved ventricular fibrillation mean frequency, which correlated positively with coronary perfusion pressure, and mean arterial pressure.

Animals↗

Intubating laryngeal mask airway, laryngeal tube, 1100 ml self-inflating bag-alternatives for basic life support?

Insufficient oxygenation, ventilation and gastric inflation with subsequent regurgitation of stomach contents is a major hazard of bag-valve-face mask ventilation during the basic life support phase of cardiopulmonary resuscitation (CPR). The European Resuscitation Council has recommended smaller tidal volumes of approximately 500 ml as an effort to reduce gastric inflation; furthermore, the intubating laryngeal mask airway and the laryngeal tube have been recently developed in order to provide rapid ventilation and to secure the airway. The purpose of our study was to examine whether usage of a newly developed medium-size self-inflating bag (maximum volume, 1100 ml) in association with the intubating laryngeal mask airway, and laryngeal tube may provide adequate lung ventilation, while reducing the risk of gastric inflation in a bench model simulating the initial phase of CPR. Twenty house officers volunteered for our study. When using the laryngeal tube, and the intubating laryngeal mask airway, respectively, the medium-size (maximum volume, 1100 ml) versus adult (maximum volume, 1500 ml) self-inflating bag resulted in significantly (P<0.05) lower mean+/-S.E.M. lung tidal volumes (605+/-22 vs. 832+/-4 ml, and 666+/-27 vs. 887+/-37 ml, respectively), but comparable peak airway pressures. No gastric inflation occurred when using both devices with either ventilation bag. In conclusion, both the intubating laryngeal mask airway and laryngeal tube in combination with both an 1100 and 1500 ml maximum volume self inflating bag proved to be valid alternatives for emergency airway management in a bench model of a simulated unintubated cardiac arrest victim.

Adult↗

Effectiveness of various airway management techniques in a bench model simulating a cardiac arrest patient.

The purpose of this study was to assess the levels of lung and gastric tidal volumes paramedics achieve when performing ventilation with bag-valve-mask, laryngeal mask, and Combitube. Twenty paramedics performed ventilation with a bag-valve mask, laryngeal mask, and Combitube in a bench model simulating an unintubated cardiorespiratory arrest patient. Lung and gastric tidal volumes and lung and gastric peak airway pressures were subsequently measured. The results showed that mean +/- SEM lung tidal volumes were significantly higher with the laryngeal mask and Combitube compared to the bag-valve-mask (701 +/- 264 vs. 742 +/- 311 vs. 353 +/- 110 mL, respectively). No gastric inflation occurred with the Combitube; gastric inflation was significantly lower with the laryngeal mask compared to the bag-valve-mask (25 +/- 15 vs. 230 +/- 25 mL, respectively). Both the laryngeal mask and Combitube proved to be valid alternatives for bag-valve-mask ventilation in our bench model simulating an unintubated patient with cardiorespiratory arrest.

Adult↗

The effects of positive end-expiratory pressure during active compression decompression cardiopulmonary resuscitation with the inspiratory threshold valve.

UNLABELLED: The use of an inspiratory impedance threshold valve (ITV) during active compression-decompression (ACD) cardiopulmonary resuscitation (CPR) improves perfusion pressures, and vital organ blood flow. We evaluated the effects of positive end-expiratory pressure (PEEP) on gas exchange, and coronary perfusion pressure gradients during ACD + ITV CPR in a porcine cardiac arrest model. All animals received pure oxygen intermittent positive pressure ventilation (IPPV) at a 5:1 compression-ventilation ratio during ACD + ITV CPR. After 8 min, pigs were randomized to further IPPV alone (n = 8), or IPPV with increasing levels of PEEP (n = 8) of 2.5, 5.0, 7.5, and 10 cm H(2)O for 4 consecutive min each, respectively. Mean +/- SEM arterial oxygen partial pressure decreased in the IPPV group from 150 +/- 30 at baseline after 8 min of CPR to 110 +/- 25 torr at 24 min, but increased in the PEEP group from 115 +/- 15 to 170 +/- 25 torr with increasing levels of PEEP (P <0.02 for comparisons within groups). Mean +/- SEM diastolic aortic minus diastolic left ventricular pressure gradient was significantly (P < 0.001) higher after the administration of PEEP (24 +/- 0 vs 17 +/- 1 mm Hg with 5 cm H(2)O of PEEP, and 26 +/- 0 vs 17 +/- 1 mm Hg with 10 cm H(2)O of PEEP), whereas the diastolic aortic minus right atrial pressure gradient (coronary perfusion pressure) was comparable between groups. Furthermore, systolic aortic pressures were significantly (P < 0.05) higher with 10 cm H(2)O of PEEP when compared with IPPV alone (68 +/- 0 vs 59 +/- 2 mm Hg). In conclusion, when CPR was performed with devices designed to improve venous return to the chest, increasing PEEP levels improved oxygenation. Moreover, PEEP significantly increased the diastolic aortic minus left ventricular gradient and did not affect the decompression phase aortic minus right atrial pressure gradient. These data suggest that PEEP reduces alveolar collapse during ACD + ITV CPR, thus leading to an increase in indirect myocardial compression. IMPLICATIONS: Inspiratory impedance during active compression-decompression cardiopulmonary resuscitation improves perfusion pressures, and vital organ blood flow during cardiac arrest. Increasing levels of positive end-expiratory pressure during performance of active compression-decompression cardiopulmonary resuscitation with an inspiratory impedance valve improves oxygenation, and increases the diastolic aortic-left ventricular pressure gradient and systolic arterial blood pressure.

Air Pressure↗

The effects of endogenous and exogenous vasopressin during experimental cardiopulmonary resuscitation.

Exogenous vasopressin is a promising vasopressor when blood pressure is critically threatened, but the role of endogenous vasopressin during cardiopulmonary resuscitation (CPR) is unknown. We assessed the role of endogenous versus exogenous vasopressin in a porcine open chest CPR model. Seven minutes before induction of cardiac arrest, seven pigs received 10 microg/kg of a selective vasopressin V(1)-receptor-antagonist (Blocked Vasopressin group); another 12 pigs in two groups received saline administration only. After 4 min of untreated ventricular fibrillation followed by 3 min of basic life support CPR, six animals received 0.8 U/kg vasopressin (Exogenous Vasopressin group), whereas the blocked vasopressin group (n = 7), and the remaining six animals received saline placebo only (Endogenous Vasopressin group). Defibrillation was attempted after 14 min of CPR. During basic life support CPR, left ventricular myocardial blood flow was significantly (P < 0.05) decreased in the Blocked Vasopressin group compared with the Exogenous Vasopressin group and Endogenous Vasopressin group (42 +/- 5 compared with 64 +/- 6 and 66 +/- 6 mL x min(-1) x 100g(-1)). Left ventricular myocardial blood flow was significantly decreased in the Blocked Vasopressin group versus Exogenous Vasopressin group versus Endogenous Vasopressin group 90 s and 5 min after drug administration, respectively (38 +/- 4 and 27 +/- 3 vs 145 +/- 32 and 110 +/- 12 vs 62 +/- 4 and 56 +/- 6 mL x min(-1) x 100g(-1), respectively). None of seven Blocked Vasopressin animals, six of six Exogenous Vasopressin pigs, and six of six Endogenous Vasopressin swine had return of spontaneous circulation after 14 min of cardiac arrest including 10 min of CPR (P < 0.05). In conclusion, pigs with blocked endogenous vasopressin had poor coronary perfusion pressure and left ventricular myocardial blood flow during open chest CPR, and could not be successfully resuscitated. All pigs with effective endogenous vasopressin or pigs with effective endogenous vasopressin and additional exogenous vasopressin had good left ventricular myocardial blood flow during experimental CPR, and survived the 1-h postresuscitation phase. We conclude that endogenous vasopressin is an adjunct vasopressor to epinephrine and may serve as a back-up regulator to maintain cardiocirculatory homeostasis.

Animals↗

A comparison of the endotracheal tube and the laryngeal mask airway as a route for endobronchial lidocaine administration.

Drug administration via the endotracheal tube is recommended as a second-line approach in emergency settings such as cardiac arrest. It is unknown what amount of drugs are absorbed when they are given through the laryngeal mask airway as compared with the endotracheal tube. We administered lidocaine at a dose of 2 mg/kg diluted in 10 mL normal saline to 20 anesthetized patients undergoing routine surgical procedures. Ten patients received lidocaine into the endotracheal tube and 10 patients received lidocaine into the laryngeal mask airway. Blood samples were taken for measurement of lidocaine plasma concentrations, and the pharmacokinetics were calculated. Therapeutic plasma concentrations (>1.4 microg/mL) could be achieved in 10 of 10 patients after endotracheal tube instillation but in only 4 of 10 patients after laryngeal mask instillation (P < 0.05). Peak lidocaine concentrations (2.47 and 1.09 microg/mL) (P < 0.05) and the area under the time versus plasma concentration curve (117.7 and 91.2 microg x min x mL(-1)) (P < 0.05) were higher after lidocaine administration into the endotracheal tube than into the laryngeal mask airway. In conclusion, the laryngeal mask airway is not a reliable route for the recommended dose of endobronchial lidocaine administration compared with the endotracheal tube.

Adult↗

Improving standard cardiopulmonary resuscitation with an inspiratory impedance threshold valve in a porcine model of cardiac arrest.

To improve the efficiency of standard cardiopulmonary resuscitation (CPR), we evaluated the potential value of impeding respiratory gas exchange selectively during the decompression phase of standard CPR in a porcine model of ventricular fibrillation. After 6 min of untreated cardiac arrest, anesthetized farm pigs weighing 30 kg were randomized to be treated with either standard CPR with a sham valve (n = 11) or standard CPR plus a functional inspiratory impedance threshold valve (ITV(TM)) (n = 11). Coronary perfusion pressure (CPP) (diastolic aortic minus right atrial pressure) was the primary endpoint. Vital organ blood flow was assessed with radiolabeled microspheres after 6 min of CPR, and defibrillation was attempted 11 min after starting CPR. After 2 min of CPR, mean +/- SEM CPP was 14 +/- 2 mm Hg with the sham valve versus 20 +/- 2 mm Hg in the ITV group (P < 0.006). Significantly higher CPPs were maintained throughout the study when the ITV was used. After 6 min of CPR, mean +/- SEM left ventricular and global cerebral blood flows were 0.10 +/- 0.03 and 0.19 +/- 0.03 mL. min(-1). g(-1) in the Control group versus 0.19 +/- 0.03 and 0.26 +/- 0.03 mL. min(-1). g(-1) in the ITV group, respectively (P < 0.05). Fifteen minutes after successful defibrillation, 2 of 11 animals were alive in the Control group versus 6 of 11 in the ITV group (not significant). In conclusion, use of an inspiratory impedance valve during standard CPR resulted in a marked increase in CPP and vital organ blood flow after 6 min of cardiac arrest.

Animals↗

The efficacy of epinephrine or vasopressin for resuscitation during epidural anesthesia.

Cardiopulmonary resuscitation (CPR) during epidural anesthesia is considered difficult because of diminished coronary perfusion pressure. The efficacy of epinephrine and vasopressin in this setting is unknown. Therefore, we designed this study to assess the effects of epinephrine versus vasopressin on coronary perfusion pressure in a porcine model with and without epidural anesthesia and subsequent cardiac arrest. Thirty minutes before induction of cardiac arrest, 16 pigs received epidural anesthesia with bupivacaine while another 12 pigs received only saline administration epidurally. After 1 min of untreated ventricular fibrillation, followed by 3 min of basic life-support CPR, Epidural Animals and Control Animals randomly received every 5 min either epinephrine (45, 45, and 200 microg/kg) or vasopressin (0.4, 0.4, and 0.8 U/kg). During basic life-support CPR, mean +/- SEM coronary perfusion pressure was significantly lower after epidural bupivacaine than after epidural saline (13 +/- 1 vs 24 +/- 2 mm Hg, P < 0.05). Ninety seconds after the first drug administration, epinephrine increased coronary perfusion pressure significantly less than vasopressin in control animals without epidural block (42 +/- 2 vs 57 +/- 5 mm Hg, P < 0.05), but comparably to vasopressin after epidural block (45 +/- 4 vs 48 +/- 6 mm Hg). Defibrillation was attempted after 18 min of CPR. After return of spontaneous circulation, bradycardia required treatment in animals receiving vasopressin, especially with epidural anesthesia. Systemic acidosis was increased in animals receiving epinephrine than vasopressin, regardless of presence or absence of epidural anesthesia. We conclude that vasopressin may be a more desirable vasopressor for resuscitation during epidural block because the response to a single dose is longer lasting, and acidosis after multiple doses is less severe compared with epinephrine.

Anesthesia, Epidural↗

The effects of different mouth-to-mouth ventilation tidal volumes on gas exchange during simulated rescue breathing.

UNLABELLED: The American Heart Association recommends tidal volumes of 700 to 1000 mL during mouth-to-mouth ventilation, but smaller tidal volumes of 500 mL may be of advantage to decrease the likelihood of stomach inflation. Because mouth-to-mouth ventilation gas contains only 17% oxygen, but 4% carbon dioxide, it is unknown whether 500-mL tidal volumes given during rescue breathing may result in insufficient oxygenation and inadequate carbon dioxide elimination. In a university hospital research laboratory, 20 fully conscious volunteer health care professionals were randomly assigned to breathe tidal volumes of 500 or 1000 mL of mouth-to-mouth ventilation gas (17% oxygen, 4% carbon dioxide, 79% nitrogen), or room air control (21% oxygen, 79% nitrogen) for 5 min. Arterial blood gases were taken immediately before, and after breathing 5 min of the experimental gas composition. When comparing 500 versus 1000 mL of mouth-to-mouth ventilation tidal volumes with 500 mL of room air, 500 mL of mouth-to-mouth ventilation tidal volume resulted in significantly (P < 0.05) lower mean +/- SEM arterial oxygen partial pressure (70 +/- 1 versus 85 +/- 2 versus 92 +/- 3 mm Hg, respectively), and lower oxygen saturation (94 +/- 0.4 versus 97 +/- 0.2 versus 98 +/- 0.2%), but increased arterial carbon dioxide partial pressure (46 +/- 1 versus 40 +/- 1 versus 39 +/- 1 mm Hg, respectively). Sixteen of 20 volunteers had to be excluded from the experiment with 500 mL of mouth-to-mouth ventilation gas after about 3 min instead of after 5 minutes as planned because of severe nervousness, sweating, and air hunger. We conclude that during simulated mouth-to-mouth ventilation, only large (approximately 1000 mL), but not small (approximately 500 mL) tidal volumes were able to maintain both sufficient oxygenation and adequate carbon dioxide elimination. IMPLICATIONS: To provide efficient mouth-to-mouth ventilation, it is important to administer tidal volumes of 1000 mL; tidal volumes of 500 mL were not adequate.

Adult↗

The predictive value of ventricular fibrillation electrocardiogram signal frequency and amplitude variables in patients with out-of-hospital cardiac arrest.

UNLABELLED: We evaluated ventricular fibrillation frequency and amplitude variables to predict successful countershock, defined as pulse-generating electrical activity. We also elucidated whether bystander cardiopulmonary resuscitation (CPR) influences these electrocardiogram (ECG) variables. In 89 patients with out-of-hospital cardiac arrest, ECG recordings of 594 countershock attempts were collected and analyzed retrospectively. By using fast Fourier transformation analysis of the ventricular fibrillation ECG signal in the frequency range 0.333-15 Hz (median [range]), median frequency, dominant frequency, spectral edge frequency, and amplitude were as follows: 4.4 (2.4-7.5) Hz, 4.0 (0.7-7.0) Hz, 7.7 (3.7-13.7) Hz, and 0.94 (0.24-1.95) mV, respectively, before successful countershock (n = 59). These values were 3.8 (0.8-7.7) Hz (P = 0.0002), 3.0 (0.3-9.7) Hz (P < 0.0001), 7.3 (2.0-14.0) Hz (P < 0.05), and 0.53 (0.03-3.03) mV (P < 0.0001), respectively, before unsuccessful countershock (n = 535). In patients in whom bystander CPR was performed (n = 51), ventricular fibrillation frequency and amplitude before the first defibrillation attempt were higher than in patients without bystander CPR (n = 38) (median frequency, 4.4 [2.4-7.5] vs 3.7 [1.8-5.3] Hz, P < 0.0001; dominant frequency, 3.8 [0.9-7.7] vs 2.6 [0.8-5.9] Hz, P < 0.0001; spectral edge frequency, 8.4 [4.8-12.9] vs 7.2 [3.9-12.1] Hz, P < 0.05; amplitude, 0.79 [0.06-4.72] vs 0.67 [0.16-2.29] mV, P = 0.0647). Receiver operating characteristic curves demonstrate that successful countershocks will be best discriminated from unsuccessful countershocks by ventricular fibrillation amplitude (3000-ms epoch). At 73% sensitivity, a specificity of 67% was obtained with this variable. IMPLICATIONS: In patients with out-of-hospital cardiac arrest, successful countershocks will be best discriminated from unsuccessful countershocks by ventricular fibrillation amplitude (3000-ms epoch). At 73% sensitivity, a specificity of 67% was obtained with this variable.

Adolescent↗

In-hospital resuscitation.

A recent world expert conference on resuscitation and emergency cardiac care led to evidence-based international guidelines for cardiopulmonary resuscitation (CPR). Several changes to CPR interventions were recommended, and will have to be implemented into clinical practice. The poor prognosis of patients who suffer in-hospital cardiac arrest may be improved with developments in CPR interventions. In the present review the most important changes recommended by the new CPR guidelines and the latest promising CPR investigations are described, focusing on their impact on in-hospital resuscitation.

Journal Article↗

Inhibition of nitric oxide improves coronary perfusion pressure and return of spontaneous circulation in a porcine cardiopulmonary resuscitation model.

OBJECTIVE: During spontaneous circulation, nonspecific inhibition of nitric oxide synthase by N(G)-nitro-L-arginine methyl ester (L-NAME) increases systemic vascular resistance and, therefore, mean arterial pressure. If this effect can be extrapolated to cardiopulmonary resuscitation (CPR), administering L-NAME during CPR may be beneficial by maintaining or even improving coronary perfusion pressure, and hence successful defibrillation. DESIGN: Prospective, randomized laboratory investigation using an established porcine model with instrumentation for hemodynamic variables, blood gases, and defibrillation attempt. SETTING: University medical center experimental laboratory. SUBJECTS: Ten domestic pigs. INTERVENTIONS: After 4 mins of ventricular fibrillation, ten animals were randomly assigned to receive L-NAME (25 mg/kg; n = 5) or saline placebo (n = 5) (given in two doses) after 3 and 13 mins of CPR, respectively. Defibrillation was provided 5 mins after the second dose of active drug or placebo. MEASUREMENTS AND MAIN RESULTS: Mean +/- sem coronary perfusion pressure was significantly (p < .05) higher 90 secs (27 +/- 3 vs. 17 +/- 3 mm Hg), 10 mins (28 +/- 3 vs. 14 +/- 2 mm Hg), and 15 mins (21 +/- 5 vs. 7 +/- 3 mm Hg) after the first L-NAME administration compared with saline placebo. Mean +/- sem coronary perfusion pressure remained significantly higher 90 secs and 5 mins after the second L-NAME vs. saline placebo administration (19 +/- 4 vs. 6 +/- 4 mm Hg, and 17 +/- 3 vs. 4 +/- 4 mm Hg). After 22 mins of cardiac arrest, including 18 mins of CPR, four of five pigs in the L-NAME group were successfully defibrillated, and survived the 60-min postresuscitation phase. In the placebo group, none of five pigs could be defibrillated successfully (p < .05). CONCLUSIONS: Nonspecific blockade of nitric oxide synthase with L-NAME during CPR was associated with an increase in coronary perfusion pressure and resulted in significantly better initial resuscitation when compared with saline placebo.

Animals↗

Comparison of epinephrine with vasopressin on bone marrow blood flow in an animal model of hypovolemic shock and subsequent cardiac arrest.

OBJECTIVE: The intraosseous route is an emergency alternative for the administration of drugs and fluids if vascular access cannot be established. However, in hemorrhagic shock or after vasopressors are given during resuscitation, bone marrow blood flow may be decreased, thus impairing absorption of intraosseously administered drugs. In this study, we evaluated the effects of vasopressin vs. high-dose epinephrine in hemorrhagic shock and cardiac arrest on bone marrow blood flow. DESIGN: Prospective, randomized laboratory investigation that used an established porcine model for measurement of hemodynamic variables and organ blood flow. SETTING: University hospital laboratory. SUBJECTS: Fourteen pigs weighing 30 +/- 3 kg. INTERVENTIONS: Radiolabeled microspheres were injected to measure bone marrow blood flow during a prearrest control period and during hypovolemic shock produced by rapid hemorrhage of 35% of the estimated blood volume. In the second part of the study, ventricular fibrillation was induced; after 4 mins of untreated cardiac arrest and 4 mins of standard cardiopulmonary resuscitation, a bolus dose of either 200 microg/kg epinephrine (n = 6) or 0.8 units/kg vasopressin (n = 6) was administered. Defibrillation was attempted 2.5 mins after drug administration, and blood flow was assessed again at 5 and 30 mins after successful resuscitation. MEASUREMENTS AND MAIN RESULTS: Mean +/- sem bone marrow blood flow decreased significantly during induction of hemorrhagic shock from 14.4 +/- 4.1 to 3.7 +/- 1.8 mL.100 g-1.min-1 in the vasopressin group and from 18.2 +/- 4.0 to 5.2 +/- 1.0 mL.100 g-1.min-1 in the epinephrine group (p =.025 in both groups). Five minutes after return of spontaneous circulation, mean +/- sem bone marrow blood flow was 3.4 +/- 1.1 mL.100 g-1.min-1 after vasopressin and 0.1 +/- 0.03 mL.100 g-1.min-1 after epinephrine (p =.004 for vasopressin vs. epinephrine). At the same time, bone vascular resistance was significantly (p =.004) higher in the epinephrine group when compared with vasopressin (1455 +/- 392 vs. 43 +/- 19 mm Hg. mL-1.100 g.min, respectively). CONCLUSIONS: Bone blood flow responds actively to both the physiologic stress response of hemorrhagic shock and vasopressors given during resuscitation after hypovolemic cardiac arrest. In this regard, bone marrow blood flow after successful resuscitation was nearly absent after high-dose epinephrine but was maintained after high-dose vasopressin. These findings emphasize the need for pressurized intraosseous infusion techniques, because bone marrow blood flow may not be predictable during hemorrhagic shock and drug therapy.

Animals↗