Comparison of direct and indirect measurements of respiratory airflow: implications for hypopneas.

The purpose of this study was to compare indirect methods for measuring respiratory airflow, such as temperature difference between inspired and expired air, thoracoabdominal movements, and nasal respiratory-airflow pressures-with a more direct measurement of minute ventilation using a head-out body plethysmograph. Measurements were obtained in healthy, awake, seated subjects during sequences of different levels of voluntary hypoventilations at 20 breaths/minute and analyzed to determine how well different methods could identify hypopneas (defined as reduction in minute ventilation by 50% or more). The results varied widely between different methods. Sensitivities ranged from 0 to 1, specificity ranged from 0.33 to 1, positive predictive values (PPV) ranged from 0 to 0.73, negative predictive values (NPV) ranged from 0.68 to 0.93. Cohen's kappa varied between 0 and 0.65 The poorest agreement was for the thermistor method, and the best agreement was obtained when a combination of thoraco-abdominal movements and nasal respiratory-airflow pressure was employed (sensitivity = 0.86, specificity = 0.83, PPV = 0.71, NPV = 0.92, Cohen's kappa = 0.65). We conclude that none of the indirect methods investigated, individually or in combination, proved adequate for identification of voluntary hypopneas in awake individuals.

Humans↗

The effects of cardioplegic arrest on right atrial function.

Atrial electrical and mechanical activity persists during cardioplegic arrest. It has been postulated that atrial ischemia may occur and cause deterioration in atrial function. This study was designed to assess the effect of cardioplegic arrest on right atrial function. Twenty-one pigs were placed on cardiopulmonary bypass (CPB), and the right atrium was isolated from the circulation by snaring both venae cavae and incising the coronary sinus. The tricuspid valve was closed through a small right ventriculotomy, and baseline atrial function was assessed using a compliant balloon in the atrium. Fourteen pigs underwent one hour of cardioplegic arrest (7 with cardioplegia alone [CCA group] and 7 with the addition of topical hypothermia [CCA + TH group]) followed by one hour of normothermic reperfusion. Seven other pigs were placed on CPB for the same period of time (CPB group). Atrial electrical and mechanical activity persisted at 45 beats per minute in the CCA group but was virtually abolished in the CCA + TH group. Cardioplegic arrest caused considerable deterioration in right atrial function (developed pressure, 18.9 +/- 0.8 [baseline] versus 14.1 +/- 0.7 mm Hg; p less than 0.05; first derivative of atrial pressure [dP/dt], 187 +/- 19 versus 134 +/- 25 mm Hg per second; p less than 0.05; 60 minutes of reperfusion and balloon volume of 20 ml). It was not affected by topical cooling. Right atrial developed pressure was maintained, but dP/dt was significantly reduced in the CPB group. This study suggests that cardioplegic arrest does not protect the atrium.

Animals↗

Is atrial function affected by conventional cardioplegic arrest?

Conventional cardioplegic arrest results in persistent atrial electrical and mechanical activity. This activity has been postulated to result in atrial ischemia which can induce postoperative arrhythmias and impair the transport function of the atrium. In this study, the effects of simple cardiopulmonary bypass (CPB) (seven pigs) and conventional cardioplegic arrest (CCA) (seven pigs) on right atrial function were evaluated. Function was assessed in an isolated right atrial preparation with a compliant balloon inserted via the superior vena cava. CCA for 1 hr produced significant deterioration in right atrial function (developed pressure 14.1 +/- 0.7 vs 18.9 +/- 0.8 mm Hg, P less than 0.05, diastolic pressure 10.0 +/- 1 vs 4.5 +/- 1.4 mm Hg, P less than 0.05, dP/dt 134 +/- 25 vs 187 +/- 19 mm Hg/sec, P less than 0.05 at a balloon volume of 20 ml after 1 hr of reperfusion). CPB alone caused no alteration in pressures in the right atrium but was associated with a late decrease in dP/dt (developed pressure 19.3 +/- 1.8 vs 18.9 +/- 0.8 mm Hg, diastolic pressure 4.0 +/- 1.2 vs 4.5 +/- 1.4 mm Hg, dP/dt 148 +/- 18 vs 187 +/- 19, P less than 0.05 at a balloon volume of 20 ml at a time corresponding to 1 hr of reperfusion in the CCA group). These results are consistent with the postulate that conventional techniques of cardioplegic arrest are associated with ischemic dysfunction of the right atrium.

Animals↗

The hemodynamic effects and mechanism of action of pulmonary artery balloon counterpulsation in the treatment of right ventricular failure during left heart bypass.

The efficacy of pulmonary artery balloon counterpulsation (PABC) was evaluated in improving right ventricular (RV) output during left heart bypass for global cardiac failure. In 13 pigs, a 40-ml balloon was positioned within a graft anastomosed to the pulmonary artery distal to the pulmonary valve, and left heart bypass was instituted from the left atrium to the carotid artery. Global myocardial failure was produced by an infusion of propranolol (range, 25 to 78 mg). In this model, RV output decreased despite volume loading to a right atrial pressure of 15 mm Hg and atrioventricular sequential pacing at 100 beats per minute. Pulmonary artery balloon counterpulsation increased both RV output (from 519 +/- 76 to 1,117 +/- 110 ml/min; p less than 0.01) and RV systolic stroke work (from 1.3 +/- 0.4 to 2.3 +/- 0.6 gm-m; p less than 0.01). Right atrial pressure decreased (from 15.5 +/- 0.9 to 10.7 +/- 1.0 mm Hg; p less than 0.01) in 8 of the pigs studied during RV failure. In 5 pigs, ventricular fibrillation occurred without a stable model of RV failure, and there was no cardiac output before or after counterpulsation. The mechanism of action of PABC was studied by placing a flow probe around a large branch of the right pulmonary artery. During RV failure, balloon inflation caused flow through the pulmonary circulation, and ventricular systole resulted in filling of the graft. During ventricular fibrillation, balloon inflation and deflation produced only a to-and-fro movement of blood in the pulmonary artery branch without net forward flow.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Preformed catheters for simplified transbrachial coronary arteriography.

The experience in 700 patients of transbrachial selective coronary arteriography using a preformed catheter is described. The excellent plastic memory of torque control of the polyurethane catheter combined with the characteristic gentle curve permit rapid and easy intubation of the coronary arteries. The so-called "difficult" cases encountered with the classic Sones technique have been catheterized with ease employing the technique described in this report. The exceptionally low complication rate (no deaths), abbreviated catheterization time, a success rate of 99.2%, and the high quality cine angiographic films make this technique a highly useful and effective method of transbrachial coronary arteriography.

Brachial Artery↗

Comprehensive presentation of semicircular canal sensitivity.

It is generally agreed that in order to determine any difference in vestibular sensitivity between the two inner ears, the best clinical procedure involves a quantitative expression of the slow phase nystagmus response to standardized caloric (or rotatory) stimulation. The preferred procedure has involved averaging the slopes of a few of the nystagmus responses during the period of most intense activity and this has been accomplished either arithmetically or by means of an electronic computer. Although, such a sampling is often sufficient to enable a reliable diagnosis, occasions do arise when the results can be misleading unless comprehensive total presentations of the responses from the two labyrinths are available for reliable comparative evaluation. Such a procedure has been developed at the University of Toronto and used for clinical assessment at St. Michael's Hospital. The reliability of the method has been established as the result of testing over 800 patients with various vestibular disorders.

Caloric Tests↗

Hyperkalemia with cardiac arrhythmia. Induction by salt substitutes, spironolactone, and azotemia.

In two patients, severe hyperkalemia and serious cardiac arrhythmia developed after excessive use of potassium-containing salt substitutes. Both had impaired ability to handle and excrete additional potassium load due to chronic congestive heart failure, azotemia, and administration of spironolactone. Prompt recognition of the arrhythmia and immediate restoration of the cardiac rate and rhythm by pacemaker support followed by intensive regimen to lower the serum potassium prevented a potentially fatal outcome. These cases emphasize the potential danger of salt substitutes when used by patients who are predisposed to retain potassium.

Aged↗