Simultaneous determination of beta-lactamic antibiotics by a new high-performance low-pressure chromatographic system using a multisyringe burette coupled to a monolithic column (MSC).

A technique based on multisyringe chromatography (MSC) was developed to determine three beta-lactamic antibiotics. Amoxicillin (AMOXI), ampicillin (AMPI) and cephalexin (CEPHA) were analyzed using a system with a very simple design and very low-cost equipment consisting of a multisyringe module, three low-pressure solenoid valves, a monolithic Chromolith Flash RP-18e column and a diode array spectrophotometric detector monitoring at 250 nm. Mobile phases containing methanol:acetic acid (0.1 M)-sodium acetate (0.1 M), pH 6.2, were tested for various ratios of methanol:acetic acid-sodium acetate, but a ratio of 10:90 gave optimum results with a flow rate of 2 ml min(-1). Validation parameters were evaluated for amoxicillin. The response to amoxicillin was linear over the range 0.04-0.4 mg/mL, with a correlation coefficient of 0.9996; precisions, evaluated as the repeatability for 0.04, 0.16 and 0.4 mg/mL amoxicillin, were 0.6%, 0.1% and 0.6%, respectively. Recovery from a generic formulation of amoxicillin was evaluated. The method showed selectivity in the presence of excipients commonly used in capsules, and satisfactory specificity was observed for amoxicillin and hydrolytic degradation products. The linearity was also evaluated for cephalexin and ampicillin. The conditions selected for MSC separation were compared with those for a HPLC system, and similar results were obtained in terms of chromatographic parameters but a difference in retention times was observed.

Amoxicillin↗

Hyphenating multisyringe flow injection lab-on-valve analysis with atomic fluorescence spectrometry for on-line bead injection preconcentration and determination of trace levels of hydride-forming elements in environmental samples.

In this work the third generation of flow injection analysis, that is, the so-called micro-lab-on-valve (microLOV) approach, is proposed for the first time for the separation, preconcentration, and monitoring of metalloids as hyphenated with atomic fluorescence spectrometry (AFS). This was made feasible by interfacing the micromachined LOV-module with AFS by a multisyringe flowing stream network for on-line postcolumn derivatization of the eluate aimed at generation of hydride species. The potential of this new hyphenated technique for environmental assays was ascertained via determination of ultratrace level concentrations of total inorganic arsenic in freshwater. Employing quantitative preoxidation of As(III) to As(V) in the samples by means of permanganate, the method involves preconcentration of arsenate at pH 10 on a renewable anion exchanger, namely, Q-Sepharose, packed in a LOV microcolumn. The analyte species is afterward stripped out and concurrently prereduced by a 300 microL eluent plug containing 6 mol L(-)1 HCl and 10% KI. The eluate is downstream merged with a metered volume of sodium tetrahydroborate (0.3% w/v) for generation of arsine, which is subsequently quantified by AFS. The flow system facilitates on-column reduction of the retained arsenic with no need for application of programmable stopped flow. Yet, the high concentration of reductant and extreme pH conditions for elution hinder the sorbent to be reused due to gradual deactivation of the functional moieties, so that maximum benefit can be taken from the application of the bead renewable strategy. The proposed procedure is characterized by a high tolerance to metal species and interfering hydride-forming elements. In fact, ratios of Se(IV) to As < or = 5000 and Sb(V) to As < or = 500 are tolerated at the 10% interference level. Under the optimized experimental conditions, a detection limit (3sigma) of 0.02 ng mL(-1) As, a dynamic linear range of 0.05-2.0 ng mL(-1) As (by tailoring the AFS gain), an enrichment factor of 8.8 for arsenate, and a precision better than 6.0% at the 0.1 ng mL-1 level were obtained for the bead-injection mode whenever the loading sample volume was affixed at 3.0 mL. The reliability and accuracy of the automated procedure was ascertained by determining total inorganic arsenic in both spiked environmental waters and certified reference materials of variable matrix complexity (TMDA-54.3 and ERM-CA010) at the low ng mL(-1) level. No significant differences were found between the experimental results and the certified values at a significance level of 0.05.

Journal Article↗

Automated on-line renewable solid-phase extraction-liquid chromatography exploiting multisyringe flow injection-bead injection lab-on-valve analysis.

In this paper, the third generation of flow injection analysis, also named the lab-on-valve (LOV) approach, is proposed for the first time as a front end to high-performance liquid chromatography (HPLC) for on-line solid-phase extraction (SPE) sample processing by exploiting the bead injection (BI) concept. The proposed microanalytical system based on discontinuous programmable flow features automated packing (and withdrawal after single use) of a small amount of sorbent (<5 mg) into the microconduits of the flow network and quantitative elution of sorbed species into a narrow band (150 microL of 95% MeOH). The hyphenation of multisyringe flow injection analysis (MSFIA) with BI-LOV prior to HPLC analysis is utilized for on-line postextraction treatment to ensure chemical compatibility between the eluate medium and the initial HPLC gradient conditions. This circumvents the band-broadening effect commonly observed in conventional on-line SPE-based sample processors due to the low eluting strength of the mobile phase. The potential of the novel MSFI-BI-LOV hyphenation for on-line handling of complex environmental and biological samples prior to reversed-phase chromatographic separations was assessed for the expeditious determination of five acidic pharmaceutical residues (viz., ketoprofen, naproxen, bezafibrate, diclofenac, and ibuprofen) and one metabolite (viz., salicylic acid) in surface water, urban wastewater, and urine. To this end, the copolymeric divinylbenzene-co-n-vinylpyrrolidone beads (Oasis HLB) were utilized as renewable sorptive entities in the micromachined unit. The automated analytical method features relative recovery percentages of >88%, limits of detection within the range 0.02-0.67 ng mL(-1), and coefficients of variation <11% for the column renewable mode and gives rise to a drastic reduction in operation costs ( approximately 25-fold) as compared to on-line column switching systems.

Automation↗

Flow-through optical fiber sensor for automatic sulfide determination in waters by multisyringe flow injection analysis using solid-phase reflectometry.

A software-controlled flow-through optical fiber diffuse reflectance sensor capitalized on the implementation of disk-based solid-phase pre-concentration schemes in a multisyringe flow injection analysis (MSFIA) set-up is proposed for the trace determination of sulfide in environmental waters and wastewaters. The fully automated flowing methodology is based on Fischer's coupling reaction of sulfide with N,N-dimethyl-p-phenylenediamine (DMPD) in the presence of Fe(iii) as oxidizing reagent in a 0.5 M HCl medium. The on-line generated methylene blue dye is subsequently delivered downstream to a dedicated optode cell furnished with an octadecyl-chemically modified (C(18)) disk, while continuously recording the diffuse reflectance spectrum of the pre-concentrated compound. A double regeneration protocol is finally executed to warrant minimum background noise and negligible baseline. Under the optimized chemical and hydrodynamic conditions, the optosensing MSFIA method features coefficients of variation better than 0.7%(n= 10) at 50 microg l(-1) concentration, a linear working range of 20-200 microg l(-1) sulfide, a 3sigma(blank) detection limit of 2.9 microg l(-1) sulfide and an injection throughput of 8 h(-1) for a pre-concentration sample volume of 2.9 ml. The interfacing of the robust and versatile multisyringe flow injection-based optode with a plug-in spectrophotometer furnished with a light emitting diode assures the miniaturization of the overall flow analyzer, which is, thus, readily adaptable to real-time monitoring schemes. The potential of the multisyringe flow method was assessed via the determination of sulfide traces in water samples of different complexity (namely, freshwater, seawater and wastewater).

Fiber Optic Technology↗

Automated enzymatic assays in a renewable fashion using the multisyringe flow injection scheme with soluble enzymes.

In this paper, a novel flowing stream scheme based upon the multisyringe flow injection (MSFI) technique is presented as a powerful tool to perform automated enzymatic assays. The exploitation of enzymes in homogeneous phase circumvents typical drawbacks associated with the commonly used packed-bead or open tubular permanent columns, namely, malfunctions of the reactor, carryover effects, flow resistance, loss of binding sites, large reagent consumption, and use of harmful organic solvents during immobilization procedures. The proposed MSFI system is able to handle minute volumes of soluble enzymes and accommodate reactions with divergent kinetic and pH demands, as demonstrated via the indirect chemiluminescence determination of trace levels of glucose. The procedure is based on the on-line glucose oxidase-catalyzed oxidation of beta-glucose in homogeneous phase to beta-glucono-delta-lactone and hydrogen peroxide. Subsequently, the generated oxidant merges downstream with an alkaline slug of 3-aminopthalhydrazide and a metal-catalyst zone (viz., Co(II)) at a total flow rate as high as 72 mL/min aiming to warrant maximum light collection from the fast CL reaction. Under optimum conditions for both sequentially occurring reactions, a glucose concentration as low as 90 microg/L may be easily detected at a 1000-fold photomultiplier gain. A second-order polynomial regression equation of light emission versus substrate concentration is found over the range 90 microg/L-2.7 mg/L glucose, although a maximum concentration of 180 mg/L may be determined by suitable gain selection without requiring manifold reconfiguration. An injection throughput of 20 h(-1), a repeatability better than 2.5% at the 1 mg/L level, and a 3sigma detection limit of 72 microg/L are the analytical features of the designed analyzer. The proposed approach was applied to the analysis of ultralow glucose content soft drinks as well as fruit juices suitable for diabetic consumers. The accuracy was assessed using the spectrophotometric batch glucose-Trinder method as an external reference methodology for the determination of the target species in parenteral solutions.

Catalysis↗

Complexation of Nickel(II) with Guanosine 5'-Monophosphate and Inosine 5'-Monophosphate: A Potentiometric and Calorimetric Study.

The constants (K(s)) and enthalpies (DeltaH(s)) for stacking interactions between purine nucleoside monophosphates were determined by calorimetry; the values thus obtained were guanosine as follows: K(s) = 2.1 +/- 0.3 M(-)(1) and DeltaH(s) = -41.8 +/- 0.8 kJ/mol for adenosine 5'-monophosphate (5'AMP); K(s) = 1.5 +/- 0.3 M(-1) and DeltaH(s) = -42.0 +/- 1.5 kJ/mol for guanosine 5'-monophosphate (5'GMP); and K(s) = 1.0 +/- 0.2 M(-1) and DeltaH(s) = -42.3 +/- 1.1 kJ/mol for inosine 5'-monophosphate (5'IMP). The interaction of nickel(II) with purine nucleoside monophosphates was studied using potentiometric and calorimetric methods, with 0.1 M tetramethylammonium bromide as the background electrolyte, at 25 degrees C. The presence in solution of the complexes [Ni(5'GMP)(2)](2)(-) and [Ni(5'IMP)(2)](2)(-) was observed. The thermodynamic parameters obtained were log K(ML) = 3.04 +/- 0.02, log K(ML2) = 2.33 +/- 0.02, DeltaH(ML) = -18.4 +/- 0.9 kJ/mol and DeltaH(ML2) = -9.0 +/- 1.9 kJ/mol for 5'GMP; and log K(ML) = 2.91 +/- 0.01, log K(ML2) = 1.92 +/- 0.01, DeltaH(ML) = -16.2 +/- 0.9 kJ/mol and DeltaH(ML2) = -0.1 +/- 2.3 kJ/mol for 5'IMP. The relationships between complex enthalpies and the degree of macrochelation, as well as the stacking interaction between purine bases in the complexes are discussed in relation to previously reported calorimetric data.