PubMed Health⌕ Search

Biomedical subjects

Valérie Desauziers

Publications and source records attributed to Valérie Desauziers.

8 recordsLinked to original sources

Comparison of two solid-phase microextraction methods for the quantitative analysis of VOCs in indoor air.

Competitive adsorption on adsorptive solid-phase microextraction (SPME) fibres implies careful determination of operating conditions for reliable quantitative analysis of VOCs in indoor air. With this objective, two analytical approaches, involving non-equilibrium and equilibrium extraction, were compared. The average detection limit obtained for GC-MS analysis of nine VOCs by the equilibrium method is 0.2 microg m(-3), compared with 1.9 microg m(-3) with the non-equilibrium method. The effect of the relative humidity of the air on the calibration plots was studied, and shown to affect acetone adsorption only. Hence, the concentrations that can be accurately determined are up to 9 micromol m(-3). The methods were then applied to indoor air containing different concentrations of VOCs. The non-equilibrium method, involving short extraction time, can be used for detection of pollution peaks whereas equilibrium extraction is preferable for measurement of sub-microg m(-3) ground concentration levels.

Adsorption↗

Study of preservation of polydimethylsiloxane/Carboxen solid-phase microextraction fibres before and after sampling of volatile organic compounds in indoor air.

Solid-phase microextraction (SPME) was applied to the on-site analysis of volatile organic compounds (VOCs) in indoor air. The compounds were at trace levels, which complicates analysis and also sample storage. Fibre storage before and after sampling was studied. Several tests were performed, and the best results were obtained for a home-made storage assembly. To avoid contamination by acetone and acetaldehyde, activated carbon was added in the storage housing. Under these conditions, fibres can be stored up to 2 days before use. After sampling, storage of 10 VOCs was evaluated by varying air relative humidity of the air. This parameter was shown to be insignificant for 3 storage days: recoveries for acetaldehyde and acetone were 149 and 176%, respectively, and ranged from 95 to 107% for the other VOCs investigated.

Air Pollutants↗

Development of a solid phase microextraction (SPME) method for the sampling of VOC traces in indoor air.

Solid-phase microextraction (SPME) was studied for the measurement of volatile organic compounds (VOCs) in indoor air. An adsorptive PDMS/Carboxen fibre was used and an analytical methodology was developed in order to overcome competitive adsorption. Kinetics and adsorption isotherms were investigated for different sample volumes and model compounds. In order to evaluate competitive adsorption on the fibre, these compounds were studied alone and in mixture. From the results obtained, the operating conditions allowing co-adsorption of the target compounds were determined: the air sample is enclosed in a 250 mL glass bulb where the SPME fibre is exposed until adsorption equilibrium. This procedure was combined with GC/MS analysis for the identification and quantification of VOCs in indoor air. The performances were determined by using a standard gas containing 10 VOCs representative of indoor environments (acetaldehyde, acetone, BTX, alpha-pinene, trichloroethylene, alkanes). The detection limits were determined in single ion monitoring mode and for a signal to noise ratio of 3. Except acetaldehyde (6 microg m(-3)), they are all below 0.5 microg m(-3). Calibration curves are linear up to 10 micromol m(-3) for all the compounds with good correlation coefficients (above 0.99). The reproducibility ranges from 6 to 12% according to the compound. The methodology was then applied to the comparison of the VOCs content in classrooms of two different schools.

Adsorption↗

Headspace SPME followed by GC/PFPD for the analysis of malodorous sulfur compounds in liquid industrial effluents.

Headspace SPME was used to analyse malodorous sulfur compounds in liquid industrial effluents. A pulsed flame photometric detector (PFPD) was selected for a specific and sensitive analysis. Two fibres, PDMS/Dvb and PDMS/Carboxen, which are particularly convenient for extracting small and volatile molecules were tested. To compare these fibres, both sensitivity and artefact formation were considered. The PDMS/Carboxen fibre showed the lower limits of detection and moreover the least artefact formation yields. It was therefore selected and headspace SPME extraction conditions were optimised. Limits of detection of the target compounds evaluated were 12-31 ng L(-1) and repeatability was around 7%. Due to the adsorption mechanism involved, extraction is strongly influenced by the sample matrix and the low affinity compounds can suffer displacement effects. To investigate the occurrence of this phenomenon, two sampling times corresponding to non-equilibrium (5 min) and equilibrium conditions (60 min) were investigated. An external calibration was carried out by using standard solutions for both sampling times. The developed procedure was then compared to the standard addition method on a real industrial effluent. The results obtained from the two methods and for the two extraction times were in good agreement, demonstrating that even a long sampling time can be used. Therefore, the simple and timesaving external calibration was defined as relevant for an accurate quantification of sulfur compounds by headspace SPME.

Journal Article↗

Evaluation of solid-phase microextraction for time-weighted average sampling of volatile sulfur compounds at ppb concentrations.

The potential of solid-phase microextraction (SPME) for time-weighted average (TWA) sampling of volatile sulfur compounds in air at ppb concentrations was investigated. The target compounds (hydrogen sulfide, methanethiol (MeSH), ethanethiol (EtSH), dimethyl sulfide (Me2S), and dimethyl disulfide (Me2S2)) were extracted using SPME with a Carboxen-poly(dimethylsiloxane) fiber coating, and diffusion was controlled by keeping the fiber retracted within the needle of the sampling device. The effects of several important experimental variables (air velocity, direction of air flow, analyte concentration, humidity, temperature, extraction time) were studied. The uptake by the fiber was not affected by the direction of the air flow or the air velocity. The effects of concentration, humidity, temperature, and extraction time were examined in experiments with a central composite face design. The results showed that all or most of the investigated parameters had a significant impact on the uptake rates of H2S, MeSH, EtSH, and Me2S, which invalidated time-weighted average sampling of these compounds by SPME under the tested conditions. Moreover, reverse diffusion of H2S, MeSH, and EtSH occurred at 40% relative humidity. For Me2S2, the uptake rate had a variation of only 8% within the whole experimental domain, and the experimental value derived for the uptake rate was consistent with the theoretical value. This result was confirmed by comparative analyses of industrial samples by the standard addition method. Therefore, SPME appears to be a suitable technique for TWA sampling of Me2S2 using the Carboxen-poly(dimethylsiloxane) fiber coating. Finally, in an investigation of potential losses during storage of the fiber, no significant losses of the target compounds were detected after 3 days at -80 degrees C.

Journal Article↗

Development of a quantification method for the analysis of malodorous sulphur compounds in gaseous industrial effluents by solid-phase microextraction and gas chromatography-pulsed flame photometric detection.

A quantification method for malodorous sulphur compounds in gaseous industrial effluents using solid-phase microextraction sampling followed by gas chromatography-pulsed flame photometric detection has been developed. A comparative study showed that polydimethylsiloxane-Carboxen fibre led to sufficient sensitivity to achieve the microg m(-3) human perception levels of the five analytes studied (hydrogen sulphide, methanethiol, ethanethiol, dimethyl sulphide, dimethyl disulphide). However, this coating is known to suffer from competitive adsorption, which may lead to inaccurate quantification. Therefore, external calibration can only be used under a limited range of concentrations, which were determined from Fick's diffusion law. This approach was tested on a real gaseous sample and compared with the standard addition method. Good correlations were found for ethanethiol, dimethyl sulphide and dimethyl disulphide. However, for more volatile sulphur compounds (i.e., hydrogen sulphide and methanethiol), the easy-to-use external calibration could not be applied and standard additions had to be performed for accurate quantification.

Calibration↗

A simple calibration procedure for volatile organic compounds sampling in air with adsorptive solid-phase microextraction fibres.

Adsorptive solid-phase microextraction (SPME) fibres have proven to be a reliable means of sampling volatile organic compounds (VOCs) in air. In this work, polydimethylsiloxane/carboxen (PDMS/CAR) fibres were used to test a new approach of air sampling strategy with SPME in the lab which could lighten calibration procedure and enhance the use of this already rapid, simple, convenient and cost effective sampling technique. Indeed, only one curve can be used whatever the extraction time chosen by the analyst under constant conditions of air velocity and temperature. Ficks' law of diffusion was used to model SPME grab sampling when the fibre was totally exposed to the air sample. Experimental sampling rates were then determined by GC-FID for different sampling conditions, i.e. in a flowing air stream of known velocity ("dynamic mode") and in a stagnant air ("static mode"). These sampling rates were found to be 3.50 and 17.80 mL min(-1) for acetone, 4.06 and 21.20 mL min(-1) for 1,2-dichloroethane, 5.10 and 27.80 mL min(-1) for toluene and 5.36 and 30.80 mL min(-1) for butyl acetate, for static and dynamic sampling modes respectively. Deviation from linearity of the calibration curves, indicating that a significant fraction of the adsorption sites are occupied, were determined. They were found to be approximately equal to 0.9, 1.57, 3.82 and 4.37 nmol for acetone, dichloroethane, toluene and butyl acetate, respectively. Experimentally determined sampling rates of these isolated compounds were also valid when a complex equimolar gaseous mixture was investigated, but deviation from linearity appears earlier. Then, for a given application, sampling times should be chosen very carefully to avoid competitive adsorption and hence, bad quantitative analysis results.

Air Pollutants↗

Dynamic versus static sampling for the quantitative analysis of volatile organic compounds in air with polydimethylsiloxane-carboxen solid-phase microextraction fibers.

Polydimethylsiloxane-Carboxen solid-phase microextraction fibers are now well known to be very efficient trapping media for the analysis of volatile organic compound (VOC) traces in air. However, competitive adsorption, due to the nature of the coating, considerably limits analyte quantitation. In this contribution, different experimental conditions are investigated to achieve quantitative analysis. Static and dynamic sampling were compared for the analysis of 11 VOCs in a standard gaseous mixture at different extraction times (1, 5, 15 and 45 min). The same experiments were performed with four isolated compounds. Adsorption results from gas mixture and isolated compounds were compared and a common linear range (i.e., where quantitative analysis is conceivable) was determined. When sampling was in the dynamic mode, compounds with lower affinity for the coating showed a very narrow linear range, meaning that competition for adsorption was quickly discriminative. The same experiments in static mode allowed one to obtain wider linear ranges for all compounds, especially for lower-affinity compounds: for a 1 min sampling time, acetone showed a linear adsorption range from 3 to 60 microg m(-3) in the dynamic mode which extended from 5 to 300 microg m(-3) in the static mode.

Air↗