Dendritic cells as a tool for the predictive identification of skin sensitisation hazard.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to Valérie Zuang.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The European Centre for the Validation of Alternative Methods (ECVAM) proposes to make the validation process more flexible, while maintaining its high standards. The various aspects of validation are broken down into independent modules, and the information necessary to complete each module is defined. The data required to assess test validity in an independent peer review, not the process, are thus emphasised. Once the information to satisfy all the modules is complete, the test can enter the peer-review process. In this way, the between-laboratory variability and predictive capacity of a test can be assessed independently. Thinking in terms of validity principles will broaden the applicability of the validation process to a variety of tests and procedures, including the generation of new tests, new technologies (for example, genomics, proteomics), computer-based models (for example, quantitative structure-activity relationship models), and expert systems. This proposal also aims to take into account existing information, defining this as retrospective validation, in contrast to a prospective validation study, which has been the predominant approach to date. This will permit the assessment of test validity by completing the missing information via the relevant validation procedure: prospective validation, retrospective validation, catch-up validation, or a combination of these procedures.
This paper outlines the research, prevalidation and validation activities that ECVAM has undertaken in collaboration with its partners in the field of topical toxicity testing and human volunteer studies, from its creation until now (1994-2002).
The European Centre for the Validation of Alternative Methods (ECVAM) Skin Irritation Task Force was established in 1996, to review the status of the development and validation of alternative tests for skin irritation and corrosion, and to identify appropriate non-animal tests for predicting human skin irritation that were sufficiently well-developed to be prevalidated and validated by ECVAM. The EpiDerm method, based on a reconstituted human skin model, was proposed as being sufficiently well advanced to enter a prevalidation (PV) study. Based on a review of test protocols, prediction models (PMs), and data submitted by test developers on ten specified chemicals, with 20% sodium lauryl sulphate as a reference standard, the task force recommended the inclusion of four other tests: EPISKIN and PREDISKIN, based on reconstituted human epidermis or on human skin; the non-perfused pig-ear test, based on pig skin; and the skin integrity function test (SIFT), with ex vivo mouse skin. The prevalidation study on these methods was funded by ECVAM, and took place during 1999-2000. The outcome of the PV study was that none of the methods was ready to enter a formal validation study, and that the protocols and PMs of the methods had to be improved in order to increase their predictive abilities. Improved protocols and PMs for the EpiDerm and EPISKIN methods, the pig ear test, and the SIFT were presented at an extended Task Force meeting held in May 2001. It was agreed that, in the short term, the performance of the revised and harmonised EpiDerm and EPISKIN methods, as well as the modified SIFT, should be evaluated in a further study with a new set of 20 test chemicals. In addition, it was decided that the SIFT and the pig ear test would be compared to see if common endpoints (transepidermal water loss, methyl green-pyronine stain) could be identified.