Using blood hemoglobin for blood analysis.

This paper demonstrates that the spectrophotometric properties of blood hemoglobin (Hb) can be used for the direct determination of biochemical compounds in blood. Glucose is used as a model, but the methodology can be applied to many other compounds (only a previous enzymatic reaction producing H(2)O(2) is needed). In order to develop the method, a model relating the Hb absorbance variation during the reaction with the glucose concentration has been developed to provide theoretical support for the method and to predict its application to other compounds. In addition, clear blood samples need to be prepared without pre-treatment and lateral reactions of H(2)O(2) with other blood constituents need to be blocked; this has been achieved with 100 : 1 v/v blood dilution in bi-distilled water and azide addition. The linear response range of the method can be fitted between 2 and 540 mg dL(-1) glucose relative to the original blood sample (RSD about 4%, 70 mg dL(-1)). The analyte concentration can be obtained by an absolute calibration method or by the standard addition method; both have been applied for direct glucose determination in several blood samples and good correlations with those obtained by an automatic analyzer have been obtained.

Absorption↗

A reagentless optical biosensor based on the intrinsic absorption properties of peroxidase.

During the reversible reaction between peroxidase (HRP) and H(2)O(2), several peroxidase intermediate species, showing different molecular absorption spectra, are formed which can be used for H(2)O(2) determination; when H(2)O(2) is generated in a previous enzymatic reaction, the substrate involved in this reaction can also be determined. On this basis, a new family of fully reversible reagentless optical biosensors containing HRP is presented; glucose determination is used as a model. The biosensor (which can be used for at least 6 months and/or more than 750 measurements) is prepared by HRP and glucose oxidase entrapment in a polyacrylamide gel matrix. A mathematical model (in which optical, kinetic and transport aspects are considered) relating the measured absorbance with the substrate concentration is also presented together with a simple methodology for characterization of this kind of biosensor. Regarding the optical model, the Kubelka-Mulk theory of reflectance does not give good results and the biosensors are better described by the Rayleigh theory of polymer solutions. Under working conditions, linear response ranges from 1.5x10(-6) to 3.0x10(-4)M glucose and CV was about 4%. This biosensor has been applied for glucose determination in fruit juices and synthetic serum samples without sample pretreatment.

Absorption↗

Application of molecular absorption properties of horseradish peroxidase for self-indicating enzymatic interactions and analytical methods.

In this paper an in depth study is presented of the use of the horseradish peroxidase (HRP) enzyme as a self-indicating biorecognition reagent in UV-vis molecular absorption spectrometry. The HRP/H2O2 reaction mechanism in the absence of an external substrate has been clarified, and the interaction between HRP and glucose oxidase (GOx) has been studied. It has been demonstrated that GOx can act as a substrate of HRP; in both cases the kinetic constants have been obtained and mathematical models have been developed. Second, the HRP/H2O2 reaction is used to follow a H2O2-producing enzymatic reaction, the glucose reaction with GOx being used as a model. As an application of this, two methodologies have been proposed for glucose determination: with or without previous incubation of glucose with GOx. In both cases mathematical models relating HRP absorbance changes to glucose concentration have been developed and tested; both methods have been optimized, analytically characterized, and tested for glucose determination in samples. The methodology described could be applied to other heme-proteins and to other H2O2-producing enzymatic reactions. The models permit the reaction constants to be calculated. From the analytical chemistry point of view the models allow the prediction of the method sensitivity for other analytes involved in this type of reaction if the kinetic constants are known and can be used in the design of optical sensors.