PubMed Health⌕ Search

Biomedical subjects

Vasiliki N Ikonomidou

Publications and source records attributed to Vasiliki N Ikonomidou.

7 recordsLinked to original sources

An adaptive filter for suppression of cardiac and respiratory noise in MRI time series data.

The quality of MRI time series data, which allows the study of dynamic processes, is often affected by confounding sources of signal fluctuation, including the cardiac and respiratory cycle. An adaptive filter is described, reducing these signal fluctuations as long as they are repetitive and their timing is known. The filter, applied in image domain, does not require temporal oversampling of the artifact-related fluctuations. Performance is demonstrated for suppression of cardiac and respiratory artifacts in 10-minute brain scans on 6 normal volunteers. Experimental parameters resemble a typical fMRI experiment (17 slices; 1700 ms TR). A second dataset was acquired at a rate well above the Nyquist frequency for both cardiac and respiratory cycle (single slice; 100 ms TR), allowing identification of artifacts specific to the cardiac and respiratory cycles, aiding assessment of filtering performance. Results show significant reduction in temporal standard deviation (SD(t)) in all subjects. For all 6 datasets with 1700 ms TR combined, the filtering method resulted in an average reduction in SD(t) of 9.2% in 2046 voxels substantially affected by respiratory artifacts, and 12.5% for the 864 voxels containing substantial cardiac artifacts. The maximal SD(t) reduction achieved was 52.7% for respiratory and 55.3% for cardiac filtering. Performance was found to be at least equivalent to the previously published RETROICOR method. Furthermore, the interaction between the filter and fMRI activity detection was investigated using Monte Carlo simulations, demonstrating that filtering algorithms introduce a systematic error in the detected BOLD-related signal change if applied sequentially. It is demonstrated that this can be overcome by combining physiological artifact filtering and detection of BOLD-related signal changes simultaneously. Visual fMRI data from 6 volunteers were analyzed with and without the filter proposed here. Inclusion of the cardio-respiratory regressors in the design matrix yielded a 4.6% t-score increase and 4.0% increase in the number of significantly activated voxels.

Adult↗

Large-amplitude, spatially correlated fluctuations in BOLD fMRI signals during extended rest and early sleep stages.

A number of recent studies of human brain activity using blood-oxygen-level-dependent (BOLD) fMRI and EEG have reported the presence of spatiotemporal patterns of correlated activity in the absence of external stimuli. Although these patterns have been hypothesized to contain important information about brain architecture, little is known about their origin or about their relationship to active cognitive processes such as conscious awareness and monitoring of the environment. In this study, we have investigated the amplitude and spatiotemporal characteristics of resting-state activity patterns and their dependence on the subjects' alertness. For this purpose, BOLD fMRI was performed at 3.0 T on 12 normal subjects using a visual stimulation protocol, followed by a 27 min rest period, during which subjects were allowed to fall asleep. In subjects who were asleep at the end of the scan, we found (a) a higher amplitude of BOLD signal fluctuation during rest compared with subjects who were awake at the end of the scan; (b) spatially independent patterns of correlated activity that involve all of gray matter, including deep brain nuclei; (c) many patterns that were consistent across subjects; (d) that average percentage levels of fluctuation in visual cortex (VC) and whole brain were higher in subjects who were asleep (up to 1.71% and 1.16%, respectively) than in those who were awake (up to 1.15% and 0.96%) at the end of the scan and were comparable with those levels evoked by intense visual stimulation (up to 1.85% and 0.76% for two subject groups); (e) no confirmation of correlation, positive or negative, between thalamus and VC found in earlier studies. These findings suggest that resting-state activity continues during sleep and does not require active cognitive processes or conscious awareness.

Adult↗

Accelerated parallel imaging for functional imaging of the human brain.

Accelerated parallel imaging (PI) techniques have recently been applied to functional imaging experiments of the human brain in order to improve the performance of commonly used single-shot techniques like echo-planar imaging (EPI). Potential benefits of PI-fMRI include the reduction of geometrical distortions due to off-resonance signals, the reduction of signal-loss in areas with substantial signal inhomogeneity, increases of the spatial and temporal resolution of the fMRI experiment and reduction of gradient acoustic noise. Although PI generally leads to a substantial decrease in image signal-to-noise ratio (SNR), its effect on the temporal stability of the signal, which ultimately determines fMRI performance, is only partially determined by image SNR. Therefore, the penalty for using PI is generally not as severe as the SNR reduction. The majority of problems related to single-shot techniques become more severe at an increased magnetic field strength, making PI an important tool in achieving the full potential of fMRI at high field.

Algorithms↗

Clinical and imaging metrics for monitoring disease progression in patients with multiple sclerosis.

Multiple sclerosis (MS) is an autoimmune disease of the CNS leading to clinical disability in 250,000-350,000 young adults in the USA and Europe. The disease affects both white matter (WM) and gray matter (GM) tissues of the brain and spinal cord. While WM disease is easily quantified using currently available magnetic resonance imaging (MRI) techniques, identification and quantification of GM disease present a daily challenge. Nonconventional brain and spinal cord MRI techniques, including magnetization transfer, MRI spectroscopy and diffusion tensor imaging, have improved our understanding of MS pathology in the deep GM. The sensitivity of high-resolution MRI obtained at a high magnetic field will improve the detection of spinal cord and brain cortical GM disease. The appropriate use of the above-mentioned techniques has the potential to more accurately explain the level of disability in MS patients.

Cognition Disorders↗

Optimizing brain tissue contrast with EPI: a simulated annealing approach.

A new magnetization preparation and image acquisition scheme was developed to obtain high-resolution brain images with optimal tissue contrast. The pulse sequence was derived from an optimization process using simulated annealing, without prior assumptions with regard to the number of radiofrequency (RF) pulses and flip angles. The resulting scheme combined two inversion pulses with the acquisition of three images with varying contrast. The combination of the three images allowed separation of gray matter (GM), white matter (WM), and cerebrospinal fluid (CSF) based on T1, contrast. It also enabled the correction of small errors in the initial T1 estimates in postprocessing. The use of three-dimensional (3D) sensitivity-encoded (SENSE) echo-planar imaging (EPI) for image acquisition made it possible to achieve a 1.15(3) mm3 isotropic resolution within a scan time of 10 min 21 s. The cortical GM signal-to-noise ratio (SNR) in the calculated GM-only image varied between 30 and 100. The novel technique was evaluated in combination with blood oxygen level-dependent (BOLD) functional magnetic resonance imaging (fMRI) on human subjects, and provided for excellent coregistration of anatomical and functional data.

Brain Mapping↗

Multirate SPAMM tagging.

Many magnetic resonance tagging sequences rely on periodicity in order to produce a uniform tagging grid that covers the whole image plane. This, however, is not always desirable, since motion may be restricted to specific parts of the image, and also different motion characteristics may call for different tagging grid densities. In this paper, we present a combination of the spatial modulation of magnetization 1-1 method with selective excitation pulses that can be used in order to restrict the tagging grid only to regions of interest and produce tagging grid of different density in each region. The method is fast and easy to implement even on older or less expensive systems, since it does not require extensive gradient switching.

Algorithms↗

A rotational approach to localized SPAMM 1-1 tagging.

Magnetic resonance tagging usually relies on controlling the phase dispersion of the transverse magnetization component. Phase dispersion is, however, affected by the inherent phase of selective excitation pulses, thus limiting their combination with tagging sequences to the application of refocusable pulses, as in the localized spatial modulation of magnetization (L-SPAMM) technique. In this study, we examine the effect of selective excitation pulses on a L-SPAMM 1-1 sequence, showing that in the case of two identical pulses the phase component is canceled out, and thus preemphasis and refocus gradients are not needed, allowing us to take advantage of a constant gradient throughout the tagging sequence, and also that one might choose nonrefocusable maximum and minimum phase pulses.

Journal Article↗