Vera Behar

Publications and source records attributed to Vera Behar.

8 recordsLinked to original sources

The combined effect of spatial compounding and nonlinear filtering on the speckle reduction in ultrasound images.

Recently, a spatial compounding ultrasound imaging method was presented that utilizes a conventional 64-element phased array transducer with two unfocused pistons, each placed at one of the sides of the phased array transducer. This method is augmented here by inclusion of nonlinear filtering of the compounded images. The combined effects of the specific spatial compounding and nonlinear filtering on speckle reduction in the generated ultrasound images are studied and evaluated in two stages: First, the image quality is studied when nonlinear filtering is used as part of the spatial compounding. The study is performed by simulations using the Field II program, by processing several B-mode images of a kidney. The second stage compares the results obtained by the simulations to those obtained by in vitro laboratory experiments. Five different compounding strategies and two nonlinear filters, Gaussian and anisotropic diffusion, are investigated and evaluated in terms of image quality parameters-contrast and signal-to-noise ratio. It is shown that the combination of "averaging+nonlinear Gaussian filtering" produces the greatest improvement of image quality. When compared to a conventional phased array imaging system, the spatial compounding method that includes the conventional 64-element phased array transducer with two unfocused pistons, and employs the "averaging+nonlinear Gaussian filtering" strategy, obtains improvement in SNR that has reached 334%. Thus, though this method necessitates a somewhat wider probe, it produces significantly improved images.

Computer Simulation↗

Optimization of sparse synthetic transmit aperture imaging with coded excitation and frequency division.

An effective aperture approach is used for optimization of a sparse synthetic transmit aperture (STA) imaging system with coded excitation and frequency division. A new two-stage algorithm is proposed for optimization of both the positions of the transmit elements and the weights of the receive elements. In order to increase the signal-to-noise ratio in a synthetic aperture system, temporal encoding of the excitation signals is employed. When comparing the excitation by linear frequency modulation (LFM) signals and phase shift key modulation (PSKM) signals, the analysis shows that chirps are better for excitation, since at the output of a compression filter the sidelobes generated are much smaller than those produced by the binary PSKM signals. Here, an implementation of a fast STA imaging is studied by spatial encoding with frequency division of the LFM signals. The proposed system employs a 64-element array with only four active elements used during transmit. The two-dimensional point spread function (PSF) produced by such a sparse STA system is compared to the PSF produced by an equivalent phased array system, using the Field II simulation program. The analysis demonstrates the superiority of the new sparse STA imaging system while using coded excitation and frequency division. Compared to a conventional phased array imaging system, this system acquires images of equivalent quality 60 times faster, when the transmit elements are fired in pairs consecutively and the power level used during transmit is very low. The fastest acquisition time is achieved when all transmit elements are fired simultaneously, which improves detectability, but at the cost of a slight degradation of the axial resolution. In real-time implementation, however, it must be borne in mind that the frame rate of a STA imaging system depends not only on the acquisition time of the data but also on the processing time needed for image reconstruction. Comparing to phased array imaging, a significant increase in the frame rate of a STA imaging system is possible if and only if an equivalent time efficient algorithm is used for image reconstruction.

Models, Theoretical↗

The combined effect of nonlinear filtration and window size on the accuracy of tissue displacement estimation using detected echo signals.

In cardiac elastography, the regional strain and strain rate imaging is based on displacement estimation of tissue sections within the heart muscle carried out with various block-matching techniques (cross-correlation, sum of absolute differences, sum of squared differences, etc.). The accuracy of these techniques depends on a combination of ultrasonic imaging parameters such as ultrasonic frequency of interrogation, signal-to-noise ratio, size of a kernel used in a block-matching algorithm, type of data and speckle decorrelation. In this paper, we discuss the possibility to enhance the accuracy of the displacement estimation via nonlinear filtering of B-mode images before block-matching operation. The combined effect of a filter algorithm and a kernel size on the accuracy of the displacement estimation is analyzed using a 36-frame sequence of grayscale B-mode images of a human heart acquired by an ultrasound system operating at 1.77 MHz. It is shown that the nonlinear filtering of images enables to obtain the desired accuracy (less than one pixel) of the displacement estimation with smaller kernels than without filtering. These results are obtained for two filters--an adaptive anisotropic diffusion filter and a nonlinear Gaussian filter chain.

Algorithms↗

Parameter optimization of pulse compression in ultrasound imaging systems with coded excitation.

A linear array imaging system with coded excitation is considered, where the proposed excitation/compression scheme maximizes the signal-to-noise ratio (SNR) and minimizes sidelobes at the output of the compression filter. A pulse with linear frequency modulation (LFM) is used for coded excitation. The excitation/compression scheme is based on the fast digital mismatched filtering. The parameter optimization of the excitation/compression scheme includes (i) choice of an optimal filtering function for the mismatched filtering; (ii) choice of an optimal window function for tapering of the chirp amplitude; (iii) optimization of a chirp-to-transducer bandwidth ratio; (iv) choice of an appropriate n-bit quantizer. The simulation results show that the excitation/compression scheme can be implemented as a Dolph-Chebyshev filter including amplitude tapering of the chirp with a Lanczos window. An example of such an optimized system is given where the chirp bandwidth is chosen to be 2.5 times the transducer bandwidth and equals 6 MHz: The sidelobes are suppressed to -80 dB, for a central frequency of 4 MHz, and to -94 dB, for a central frequency of 8 MHz. The corresponding improvement of the SNR is 18 and 21 dB, respectively, when compared to a conventional short pulse imaging system. Simulation of B-mode images demonstrates the advantage of coded excitation systems of detecting regions with low contrast.

Journal Article↗

Improving motion estimation by accounting for local image distortion.

Cardiac elastography is a useful diagnostic technique for detection of heart function abnormalities, based on analysis of echocardiograms. The analysis of the regional heart motion allows assessing the extent of myocardial ischemia and infarction. In this paper, a new two-stage algorithm for cardiac motion estimation is proposed, where the data is taken from a sequence of 2D echocardiograms. The method combines the advantages of block-matching and optical flow techniques. The first stage employs a standard block-matching algorithm (sum of absolute differences) to provide a displacement estimate with accuracy of up to one pixel. At the second stage, this estimate is corrected by estimating the parameters of a local image transform within a test window. The parameters of the image transform are estimated in the least-square sense. In order to account for typical heart motions, like contraction/expansion, translation and rotation, a local affine model is assumed within the test window. The accuracy of the new algorithm is evaluated using a sequence of 500 grayscale B-mode images, which are generated as distorted, but known copies of an original ROI, taken from a real echocardiogram. The accuracy of the motion estimation is expressed in terms of errors: maximum absolute error, root-mean-square error, average error and standard deviation. The errors of the proposed algorithm are compared with these of the known block-matching technique with cross-correlation and interpolation in the sub-pixel space. Statistical analysis of the errors shows that the proposed algorithm provides more accurate estimates of the heart motion than the cross-correlation technique with interpolation in the sub-pixel space.

Algorithms↗

A new method of spatial compounding imaging.

A new method of spatial compound imaging is presented that improves image quality without the usual requirement to decrease the frame rate. The new method of imaging utilizes three transducers for data acquisition. The transducer located at the center of the transducer system is a phased array probe that acts as both transmitter and receiver. The other transducers are unfocused pistons that act only as receivers. Envelope data acquired by each transducer are combined to form a final image with improved quality (speckle contrast, target detectability and lateral resolution). It is shown that the improvement in speckle contrast depends on the correlation between individual images acquired by the transducers. The effective aperture approach is used for analytic estimation of the correlation between images in order to optimize the lateral separation between transducers. Using simulations, several compounding strategies have been performed to find the strategy that maximizes image quality. The central frequency of 2.5 MHz is used in simulations. Quantitative analysis of simulated B-mode images shows that the new method of imaging efficiently improves visibility, detectability, and lateral resolution of low contrast regions. The image frame rate is preserved because multiple scans are not required for the spatial compounding.

Computer Simulation↗

A new method of ultrasound color flow mapping.

Conventional ultrasound color flow mapping systems estimate and visualize only the axial velocity component. To obtain the transverse velocity component a modification of a multiple-beam method is proposed. The new two-dimensional color flow mapping system has a small size and consists of three transducers. The central transducer is an appodized and focused phased array. The other transducers are unfocused probes. Three transducers act as receivers and the central transducer operates as a transmitter. All receivers acquire rf scan lines that are then processed to estimate three axial velocity components using an autocorrelation method. These estimates are then combined to estimate the transverse velocity component, taking into account the geometric relationships among three transducers. Two algorithms for transverse velocity estimation are proposed. The first uses the Doppler angle estimate for calculation of the transverse velocity component. The other algorithm calculates the transverse velocity component directly from the axial components. The accuracy of the flow velocity estimators is estimated by simulations. Analysis of accuracy allows choosing the more effective algorithm for two-dimensional velocity estimation, which is insensitive to variations of the Doppler angle.

Algorithms↗

Techniques for phase correction in coherent ultrasound imaging systems.

The problem of phase aberrations modeled as a near field thin phase screen is considered. Here three new techniques for phase aberration correction are presented. In the "central element" correction technique the echo-signal at each array element is aligned with the signal at the central array element. In the "variable speckle look-back" correction technique the signal at each array element is aligned with the sum of signals from all previously corrected elements. In the "variable central speckle look-back" correction technique the signal at each array element is aligned with the sum of signals from the central group of all previously corrected elements. The performance of new techniques for phase aberration correction is tested by means of simulating the point-spread function for both point and speckle targets. The results of simulation show that the new techniques have the better accuracy of phase correction than the classical "neighbor element" technique.

Journal Article↗