PubMed Health⌕ Search

Biomedical subjects

Vera Ignjatovic

Publications and source records attributed to Vera Ignjatovic.

8 recordsLinked to original sources

Monitoring Unfractionated Heparin (UFH) therapy: which Anti-Factor Xa assay is appropriate?

INTRODUCTION: Anti-Factor Xa (Anti-Xa) assays specifically determine the anticoagulant activity of UFH by measuring the ability of heparin-bound Antithrombin (AT) to inhibit a single enzyme, Factor Xa (FXa). Recent improvements in the automation, cost-effectiveness and accessibility of the assay to clinicians, have resulted in the Anti-Xa assay becoming a part of daily clinical practice in many institutions. OBJECTIVES: We hypothesized that different Anti-Xa assays have different applicability for use in clinical settings, depending on the amount of UFH administered. This was investigated in a tertiary paediatric institution. MATERIALS AND METHODS: Samples were collected from children receiving Low-dose of UFH of at least 10 IU/kg/h, with or without a previous bolus of up to 25 IU/kg/h, within the previous 6 h in the PICU and HDU. High-dose UFH population consisted of children undergoing Cardiac Catheterization (CC), who received a bolus of UFH of 100 IU/kg body weight, 30 min prior to sampling. RESULTS AND CONCLUSIONS: The Anti-Xa activity for a given dose of UFH was found to vary significantly based on the Anti-Xa assay and the population being monitored. Our study suggests that the MODIFIED COMATIC Anti-Xa assay provides the best physiological measure of the UFH effect in children, as it does not introduce sources of error, such as exogenous AT, which may increase the measured ant Factor Xa activity, nor Dextran Sulphate which can displace plasma protein bound heparin and once again leading to falsely elevated assay results. Further studies that include assessment of clinical outcomes are required to confirm the applicability of use of this particular assay in monitoring UFH therapy.

Anticoagulants↗

Developmental haemostasis. Impact for clinical haemostasis laboratories.

Developmental haemostasis is a concept, now universally accepted, introduced by Andrew et al. in the late 1980's. However, coagulation analysers and reagents have changed significantly over the past 15 years. Coagulation testing is known to be sensitive to changes in individual reagents and analysers. We hypothesised that the reference ranges developed by Andrew et al. may not be appropriate for use in a modern coagulation laboratory. Our study was designed to determine whether a current day coagulation testing system (STA Compact analyser and Diagnostica Stago reagent system) was sensitive to age-related changes in coagulation assays. This is the first large scale study since Andrew et al. to determine the age associated numerical changes in coagulation proteins. Our results confirm the concepts of developmental haemostasis elucidated by Andrew et al. However, our results clearly demonstrate that the absolute values of reference ranges for coagulation assays in neonates and children vary with analyser and reagent systems. The results confirm the need for coagulation laboratories to develop age-related reference ranges specific to their own testing systems. Without this, accurate diagnosis and management of neonates and children with suspected bleeding or clotting disorders is not possible. Finally we present age related reference ranges for D-dimers, TFPI, and endogenous thrombin potential, previously not described.

Adolescent↗

Age-related differences in heparin response.

INTRODUCTION: Major physiological differences in the coagulation system throughout childhood, compared to adults, are well documented. However, the impact of this on anticoagulant drugs is unknown. This study aimed to determine whether heparin therapeutic range determination is affected by the age of plasma donors and whether age-specific therapeutic ranges for heparin therapy may need to be considered in the clinical setting. MATERIALS AND METHODS: Plasma samples were obtained from healthy children and adults, and pooled into age-specific pools. These were spiked with different concentrations of heparin and APTT; Anti-Factor Xa and Anti-Factor IIa were measured using standard techniques. The experiments were repeated using three separate plasma pools, and results expressed as means with standard deviations. RESULTS AND CONCLUSIONS: The results show clear age-related differences in APTT for the same Anti-Factor Xa heparin concentration. The differences were more pronounced in younger children, with higher APTT for same Anti-Factor Xa. The Anti-Factor IIa activity of heparin for a given Anti-Factor Xa activity also differed between age-specific plasma pools. This study suggests that when using heparin in children, basic assumptions about the drug mechanism of action and implications for therapeutic ranges need to be considered.

Adolescent↗

Early evolution of the venom system in lizards and snakes.

Among extant reptiles only two lineages are known to have evolved venom delivery systems, the advanced snakes and helodermatid lizards (Gila Monster and Beaded Lizard). Evolution of the venom system is thought to underlie the impressive radiation of the advanced snakes (2,500 of 3,000 snake species). In contrast, the lizard venom system is thought to be restricted to just two species and to have evolved independently from the snake venom system. Here we report the presence of venom toxins in two additional lizard lineages (Monitor Lizards and Iguania) and show that all lineages possessing toxin-secreting oral glands form a clade, demonstrating a single early origin of the venom system in lizards and snakes. Construction of gland complementary-DNA libraries and phylogenetic analysis of transcripts revealed that nine toxin types are shared between lizards and snakes. Toxinological analyses of venom components from the Lace Monitor Varanus varius showed potent effects on blood pressure and clotting ability, bioactivities associated with a rapid loss of consciousness and extensive bleeding in prey. The iguanian lizard Pogona barbata retains characteristics of the ancestral venom system, namely serial, lobular non-compound venom-secreting glands on both the upper and lower jaws, whereas the advanced snakes and anguimorph lizards (including Monitor Lizards, Gila Monster and Beaded Lizard) have more derived venom systems characterized by the loss of the mandibular (lower) or maxillary (upper) glands. Demonstration that the snakes, iguanians and anguimorphs form a single clade provides overwhelming support for a single, early origin of the venom system in lizards and snakes. These results provide new insights into the evolution of the venom system in squamate reptiles and open new avenues for biomedical research and drug design using hitherto unexplored venom proteins.

Animals↗

Reduced bone density in children on long-term warfarin.

Vitamin K is essential for development of normal bone density and achieving adequate peak bone mass in childhood and is thought to be important in preventing the development of osteoporosis in later life. Warfarin, a vitamin K antagonist, is being used with greater frequency in children. The long-term effect of warfarin on bone density of children is not known. We performed a case control study survey of bone density in children on long-term warfarin (n=17, average duration of warfarin treatment 8.2 y) compared with randomly selected controls (n=321). There was a marked reduction in bone mineral apparent density of lumbar spine between patients and controls [patients 0.10 g/cm3; 95% confidence interval (CI), 0.93-0.11 g/cm3, controls 0.12 g/cm3; 95% CI, 0.11-0.12 g/cm3, p<0.001). The lumbar spine areal bone mineral density Z-score of patients was reduced compared with controls [patients, -1.96 (95% CI, -2.52 to -1.40). This difference persisted after adjustment for age and body size. The etiology for the reduced bone density is likely to be multifactorial, however, screening of children on long-term warfarin for reduced bone density should be considered.

Adolescent↗

Point of care monitoring of oral anticoagulant therapy in children: comparison of CoaguChek Plus and Thrombotest methods with venous international normalised ratio.

This paper reports the outcome of a research protocol aimed at optimising warfarin monitoring in a tertiary pediatric centre. The Thrombotest INR was the standard monitoring test employed to manage oral anticoagulant therapy in children at the Royal Children's Hospital (RCH), Melbourne. This study compares the results of this standard method to the novel CoaguChek INR monitor and the "gold standard" technique of venous INR sampling. The objectives were to determine 1) if point-of-care techniques of measuring the INR (Thrombotest and CoaguChek) are accurate and reliable compared to INR results obtained from venous sampling, processed in an accredited laboratory, and 2) if INR results generated by POC devices can be safely used to manage oral anticoagulant therapy in children. 18 children (10 females and 8 males) participated in the study. Ages ranged from 9 months to 21 years (Mean 11.9 years; SD 5.03 years). The agreement between CoaguChek and venous INR measurements (r = 0.885) was shown to be higher compared to Thrombotest and venous INR (r = 0.700). Compared to the venous INR, values obtained with Coaguchek and Thrombotest crossed into or out of the therapeutic range in 25% and 36% of cases respectively. In 88% of the CoaguChek cases and 57% Thrombotest cases, the difference from the venous result was less than 0.5. The CoaguChek method of INR monitoring is a more accurate and reliable method compared to Thrombotest, in the pediatric population tested, and can be safely used to manage oral anticoagulant therapy in children.

Adolescent↗