PubMed Health⌕ Search

Biomedical subjects

Vicente Campos

Publications and source records attributed to Vicente Campos.

4 recordsLinked to original sources

Triflusal versus oral anticoagulation for primary prevention of thromboembolism after bioprosthetic valve replacement (trac): prospective, randomized, co-operative trial.

OBJECTIVE: Antiplatelet agents are used for prevention of thromboembolism in surgical patients and in patients with chronic atrial fibrillation. Up to date, however, results of randomized studies comparing antiplatelet agents and oral anticoagulation have not been reported. The aim of this study was to compare the efficacy and safety of triflusal (an antiplatelet agent) versus acenocoumarol for primary prevention of thromboembolism in the early postoperative period after implantation of a bioprosthesis. METHODS: In this prospective, multicentric, randomized, open pilot trial, patients were assigned to treatment with triflusal (600mg/d) or acenocoumarol (target INR 2.0-3.0). Study medication was started 24-48h after valve replacement with a bioprosthesis, and continued for 3 months. Four follow-up visits were scheduled: baseline, and at 1, 3 and 6 months thereafter. The primary end-point was a composite of the rate of thromboembolism, severe hemorrhage and valve-related mortality. RESULTS: A total of 193 patients were included (97 received triflusal and 96 acenocoumarol), with a mean age of 72.5 years. Half were men. Aortic valve replacement was performed in 181 patients (93.8%), mitral valve replacement in 10 patients (5.2%) and double valve replacement in 2 (1.0%). Hospital mortality was 11 (5.7%). Primary outcome was recorded in 9 patients with triflusal (9.4%) and in 10 patients with acenocoumarol (11%). There were nine episodes (4.7%) of thromboembolism, six in the triflusal group and three in the acenocoumarol group, and three episodes of permanent neurological deficits, one in the triflusal group and two in the acenocoumarol group. Severe hemorrhage: nine episodes, six in the acenocoumarol group and three in the triflusal group. None of the observed differences in efficacy were statistically significant. Regarding safety, three patients in triflusal group reported at least one hemorrhage, compared to 10 in acenocoumarol group (P=0.048). CONCLUSIONS: There were no significant differences in efficacy between both groups, however, triflusal showed a significantly lower incidence of bleeding episodes.

Acenocoumarol↗

[Preoperative risk evaluation in beating-heart coronary artery bypass surgery].

INTRODUCTION AND OBJECTIVES: Operative risk stratification scales for use in cardiac surgery have been developed for patients who undergo procedures using extracorporeal circulation. The aims of the present study were to investigate the use of six preoperative risk stratification scales in patients undergoing beating-heart surgery and to identify risk factors for major complications and mortality in our group of patients who underwent revascularization using this approach. PATIENTS AND METHOD: Between January 1997 and December 2002, we performed 762 coronary artery bypass operations on the beating heart; 61 patients suffered major complications (8%) and 25 died (3.3%). Risk factors for major complications and death were identified using logistic regression analysis of prospectively collected data. The following risk scores were calculated for each patient: Parsonnet 95, Parsonnet 97, Euroscore, Cleveland, Ontario, and French. Receiver operating characteristic curves were used to compare the ability of each scale to predict mortality and major complications. RESULTS: In our patient group, the preoperative variables associated with increased risk were: need for cardiopulmonary resuscitation, renal dysfunction, peripheral vasculopathy, and the presence of severe left main coronary artery disease, three-vessel disease, or an impaired ejection fraction. CONCLUSIONS: Mortality and major complications were best predicted by the Parsonnet 95 and Euroscore scales.

Adult↗

Hemodynamic Comparison by Doppler Echocardiography of Valves in the Aortic Position: Value of the Continuity Equation to Assess Prosthetic Dysfunction.

In 281 patients, we used Doppler echocardiography to compare the hemodynamic performance of different aortic prosthetic valves at three postoperative stages and investigated the value of the continuity equation in diagnosing aortic prosthetic obstruction. A baseline study was performed in 163 patients, a 5 +/- 2-month follow-up study was performed in 103 patients, and a 15 +/- 5-month follow-up study was performed in 65 patients. From baseline to the second study, left ventricular diastolic diameter, heart rate, and maximum (MG) and mean Doppler-derived gradient (MeG) decreased significantly, and left ventricular shortening fraction, systolic blood pressure, stroke volume, and prosthetic valvular area (PVA) increased significantly. No changes were found between the second and third studies. Thus, noninvasive hemodynamic values at the time of follow-up are reported in 171 patients: 86 with Björk-Shiley Monostrut, 27 with Carbomedics, 11 with Medtronic-Hall, 18 with Hancock modified, and 29 with Toronto valve bioprosthesis. Patients implanted with the Toronto had a larger prosthetic size (Monostrut 23 +/- 2 mm, Carbomedics 23 +/- 3 mm, Medtronic-Hall 23 +/- 2 mm, Hancock 23 +/- 2 mm, Toronto 25 +/- 2 mm, P < 0.01) despite a similar body surface area. MeG and MG were lower (MeG [in mmHg] Monostrut 12 +/- 5, Carbomedics 14 +/- 6, Medtronic-Hall 19 +/- 6, Hancock 11 +/- 4, Toronto 7 +/- 5; P < 0.01 between Toronto and all others), and PVA was greater (Monostrut 2.0 +/- 0.7 cm(2), Carbomedics 1.8 +/- 0.8 cm(2), Medtronic-Hall 1.6 +/- 0.7 cm(2), Hancock 1.7 +/- 0.5 cm(2), Toronto 2.2 +/- 0.9 cm(2); P < 0.01 between Toronto and Carbomedics, Medtronic-Hall, and Hancock), even compared with the same sizes in the other valves. A PVA of 0.9 cm(2) or less and MeG of 28 mmHg or more identified prosthetic obstruction with 100% sensitivity and 99% specificity. Hemodynamics change significantly from the early to the late postoperative state. The Toronto valve stentless porcine bioprostheses performs hemodynamically better than other valves. PVA measurement using the continuity equation may accurately identify prosthetic obstruction.

Journal Article↗

Off-pump total arterial revascularization: our experience.

BACKGROUND AND AIM: Off-pump coronary artery bypass grafting with both the internal thoracic arteries, such as the Tector technique, can reduce the morbidity associated with extracorporeal circulation and aortic cross-clamp. The aim of the present study is to describe our experience and the results obtained. METHODS: From April 1998 to December 2003, the off-pump Tector technique was performed on 743 patients, of whom 621 were male (83.5%), with a mean age of 65.3 +/- 9.5 years (23-90). Preoperative risk factors were diabetes mellitus in 29.5% and peripheral vasculopathy in 14.7% of the patients. Angiography showed left main disease in 25.6% and triple-vessel disease in 50.3% of the patients, with a mean ejection fraction of 60%+/- 13% (23-88). Both the internal thoracic arteries were harvested using the skeletonization technique and were anastomosed as "Y" or "T" grafts. Intraoperative graft patency was checked using a Doppler flowmeter. RESULTS: A total of 2028 distal anastomoses were performed, the average being 2.7 (1 to 5) per patient. At least three distal anastomoses were undertaken in 62% of the patients. Postoperative complications included atrial fibrillation in 40 patients (5.4%), myocardial infarction in 24 (3.2%), mediastinitis and reoperation for bleeding in 7 (0.9%) and stroke in 3 (0.4%). Twenty-four patients (3.2%) died in the first month postoperatively. CONCLUSIONS: The off-pump Tector technique appears to be safe, showing a low surgical morbidity.

Adult↗