PubMed Health⌕ Search

Biomedical subjects

Victor A Bykov

Publications and source records attributed to Victor A Bykov.

2 recordsLinked to original sources

Nanotechnologies in proteomics.

Progress in proteomic researches is largely determined by development and implementation of new methods for the revelation and identification of proteins in biological material in a wide concentration range (from 10(-3) M to single molecules). The most perspective approaches to address this problem involve (i) nanotechnological physicochemical procedures for the separation of multicomponent protein mixtures; among these of particular interest are biospecific nanotechnological procedures for selection of proteins from multicomponent protein mixtures with their subsequent concentration on solid support; (ii) identification and counting of single molecules by use of molecular detectors. The prototypes of biospecific nanotechnological procedures, based on the capture of ligand biomolecules by biomolecules of immobilized ligate and the concentration of the captured ligands on appropriate surfaces, are well known; these are affinity chromatography, magnetic biobeads technology, different biosensor methods, etc. Here, we review the most promising nanotechnological approaches for selection of proteins and kinetic characterization of their complexes based on these biospecific methods with subsequent MS/MS identification of proteins and protein complexes. Two major groups of methods for the analysis and identification of individual molecules and their complexes by use of molecular detectors will be reviewed: scanning probe microscopy (SPM) (including atomic-force microscopy) and cryomassdetector technology.

Biomarkers, Tumor↗

Atomic force microscopy detection of molecular complexes in multiprotein P450cam containing monooxygenase system.

The application of atomic force microscopy (AFM) technique in proteomic research, identification and visualization of individual molecules and molecular complexes within the P450cam containing monooxygenase system was demonstrated. The method distinguishes between the binary protein complexes and appropriate monomeric proteins and, also, between the binary and ternary complexes. The AFM images of the components of a cytochrome P450cam containing monooxygenase system - cytochrome P450cam (P450cam), putidaredoxin (Pd) and putidaredoxin reductase (PdR) - were obtained on a mica support. The molecules of P450cam, Pd and PdR were found to have typical heights of 2.6 +/- 0.3 nm, 2.0 +/- 0.3 and 2.8 +/- 0.3 nm, respectively. The measured heights of the binary Pd/PdR and P450cam/PdR complexes were 4.9 +/- 0.3 nm and 5.1 +/- 0.3 nm, respectively. The binary P450cam/Pd complexes were found to have a typical height of about (3.9 / 5.7 nm) and the ternary PdR/Pd/P450cam complexes, a typical height of about 9.1 +/- 0.3 nm.

Camphor 5-Monooxygenase↗