PubMed Health⌕ Search

Biomedical subjects

Victor David

Publications and source records attributed to Victor David.

12 recordsLinked to original sources

High-throughput liquid-chromatography method with fluorescence detection for reciprocal determination of furosemide or norfloxacin in human plasma.

A simple, high-throughput, highly selective and sensitive HPLC-FLD method for isolation and determination of furosemide and/or norfloxacin in human plasma samples following a simple organic solvent deproteinization step with acetonitrile as sample 'clean-up' procedure is reported. One of the two drug substances plays the internal standard role for the determination of the other. Separation of analyte and internal standard was achieved in less than 5.3 min (injection to injection) on a Chromolith Performance RP-18e column, using an aqueous component containing 0.015 mol/L sodium heptane-sulfonate and 0.2% triethylamine brought to pH = 2.5 with H(3)PO(4). The composition of the mobile phase was: acetonitrile-methanol-aqueous component = 70:15:15 (v/v/v) and the flow-rate was set up to 3 mL/min. The chromatographic method applied to the determination of furosemide relies on fluorescent detection parameters of 235 nm for the excitation wavelength, and 402 nm for the emission wavelength. In case of norfloxacin, the excitation wavelength is set up to 268 nm and the emission wavelength is set up to 445 nm. The overall method leads to quantitation limits of about 27 ng/mL for furosemide, and 19.5 ng/mL for norfloxacin, using an injection volume of 250 microL. The method was applied to the bioequivalence study of two furosemide-containing formulations.

Chromatography, High Pressure Liquid↗

Achiral-chiral LC/LC-FLD coupling for determination of carvedilol in plasma samples for bioequivalence purposes.

Bioequivalence data for two pharmaceutical formulations (solid oral dosage forms) containing carvedilol is presented for both racemic and enantiomers of the active substance. This was achieved by on-line coupling of two liquid chromatographic separations followed by fluorescence detection. The first LC dimension was used for a fast separation of racemic carvedilol from propranolol (IS) and the endogenous matrix, by means of a reversed phase mechanism. The peak of racemic carvedilol was on-line transferred to the second enantioselective LC dimension, based on a reversed phase separation on cellulose tris(3,5-dimethyl-phenylcarbamate) stationary phase. Both stages were monitored over a single run by means of a fluorescence detector operated at an excitation wavelength of 285 nm and an emission wavelength of 355 nm. Automated shortcutting of the racemic carvedilol peak to the chiral column and simultaneous detection over the two LC dimensions have been obtained by using an experimental set-up based on two six-port rotative switching valves. Linearity was demonstrated on the interval 2-150 ng/mL for racemic carvedilol and on 1-75 ng/mL intervals for enantiomers. LLOQ fits between 0.7 and 1.4 ng/mL. Recoveries of the target compounds are 87+/-4 and 81+/-4% for the IS. Precision ranged from 0.6 to 2.5% and the mean accuracy obtained on quality control samples (measured as % bias) over the whole study falls between -0.8 and 6.3%.

Adolescent↗

Fast RPLC-UV method on short sub-two microns particles packed column for the assay of tenoxicam in plasma samples.

An extraction-less sample preparation technique followed by a RPLC-UV method on sub-two microns particles packed short column were used for the assay of tenoxicam in plasma samples. Protein precipitation was made by means of trichloroacetic acid addition. Supernatant was injected to the chromatographic column without any further pH adjustment. The mobile phase consisted in a mixture of acetonitrile and aqueous 0.1% phosphoric acid, at 2 mL/min flow rate and gradient elution. The Zorbax SB-C18 column (50 mm length, 4.6 mm internal diameter and 1.8 microm particle size) was thermostated at 60 degrees C. The mobile phase gradient composition program allowed separation of tenoxicam and piroxicam (internal standard), column clean-up and re-equilibration within 4 min. UV detection was achieved at 368+/-10 nm. The method is characterized by a low limit of quantitation of 25 ng/mL for tenoxicam, with a linearity interval up to 5500 ng/mL. The use of a low volume detection cell and detector high frequency data acquisition rate produced high precision and accuracy through a whole bioequivalence study of tenoxicam in two commercially available tablet formulations, after a single oral administration dose. Full method validation is presented. The high throughput characteristic of the proposed method allowed full validation and bioanalytical study completion within a 96 h period.

Anti-Inflammatory Agents, Non-Steroidal↗

Determination of glibenclamide in human plasma by liquid chromatography and atmospheric pressure chemical ionization/MS-MS detection.

A simple and fast method intended for large-scale bioequivalence studies for the determination of glibenclamide in plasma samples is presented. The chromatographic separation was achieved on a monolithic octadecyl chemically modified silicagel column and a mobile phase containing 42% aqueous 0.1% HCOOH solution (v/v) and 58% acetonitrile, at a flow rate of 1 mL/min, in isocratic conditions. Preparation of plasma samples was based on protein precipitation with acetonitrile. Gliquidone was used as internal standard. The target analytes were transferred into an ion trap mass analyzer via an atmospheric pressure chemical ionization interface. The precursor ions with mass 494 a.m.u. for glibenclamide and 528 a.m.u. for gliquidone were isolated, while in the second MS stage product ions 369 a.m.u. and 403 a.m.u., respectively, were monitored. The analytical process was characterized by a low limit of quantitation of 1.5 ng/mL. The mean recovery for glibenclamide was 98.1+/-2.8% over a concentration interval ranging from 1 to 500 ng/mL. Intra-day and inter-day precision calculated over 2-400 ng/mL concentration interval ranged from 15.4% to 3.4%. Inter-sequence accuracy expressed as % bias from theoretical concentration values over the concentration interval of 10-400 ng/mL fall within -13.9% and +14.6%. The method was applied for evaluation of the bioequivalence between two formulations containing 3.5mg glibenclamide per dose.

Atmospheric Pressure↗

Genetic factors leading to chronic Epstein-Barr virus infection and nasopharyngeal carcinoma in South East China: study design, methods and feasibility.

Nasopharyngeal carcinoma (NPC) is a complex disease caused by a combination of Epstein-Barr virus chronic infection, the environment and host genes in a multi-step process of carcinogenesis. The identity of genetic factors involved in the development of chronic Epstein-Barr virus infection and NPC remains elusive, however. Here, we describe a two-phase, population-based, case-control study of Han Chinese from Guangxi province, where the NPC incidence rate rises to a high of 25-50 per 100,000 individuals. Phase I, powered to detect single gene associations, enrolled 984 subjects to determine feasibility, to develop infrastructure and logistics and to determine error rates in sample handling. A microsatellite screen of Phase I study participants, genotyped for 319 alleles from 34 microsatellites spanning an 18-megabase region of chromosome 4 (4p15.1-q12), previously implicated by a linkage analysis of familial NPC, found 14 alleles marginally associated with developing NPC or chronic immunoglobulin A production (p=0.001-0.03). These associations lost significance after applying a correction for multiple tests. Although the present results await confirmation, the Phase II study population has tripled patient enrollment and has included environmental covariates, offering the potential to validate this and other genomic regions that influence the onset of NPC.

Adolescent↗

[Association study of chromosome 4 STRs polymorphisms with nasopharyngeal carcinoma].

Nasopharyngeal carcinoma (NPC) is a complex disease caused by an interaction of EBV chronic infection, environment and host genes, in a multi-step process of carcinogenesis. However, which genetic factors play an important role in the development of chronic EBV infection and NPC remain elusive. The objective of this study is to identify genetic variations associated with two key clinical stages of NPC development: persistent Epstein-Barr virus (EBV) infection of nasopharyngeal epithelia and progression to NPC. We inspected a NPC-associated region on the short arm of chromosome 4 previously implicated by a genome-wide linkage analysis of familial NPC. We determined genotypes for 319 alleles in 34 microsatellite markers spanning an 18 Mb region in 350 NPC cases, 288 individuals with IgA antibodies to EBV capsid antigen (IgA/VCA+) and 346 controls seronegative for IgA antibodies to EBV capsid antigen (IgA/VCA-). The cases and controls were Han Chinese from Wuzhou city and Cangwu County, Guangxi province where the incidence of NPC is as high as 25-50 per 100,000 individuals. Comparing NPC cases to IgA/VCA+ subjects, we found 9 alleles marginally associated with developing NPC from IgA+ status, 5 for risk (OR=1.51-5.36, P=0.01-0.03) and 4 for restrictive (OR=0.3-0.71, P=0.02-0.045). Comparing IgA/VCA+ subjects and IgA/VCA- controls, and comparing all IgA seropositives with and without NPC to IgA seronegatives revealed 12 significant and 3 highly significant (P<0.01) alleles associated with IgA+ serostatus in the two comparing groups. Alleles D4S3241-136 (P=0.004, OR=1.91, 95% CI=1.2-3.0) and D4S3347-213 (P=0.001, OR=1.6, 95% CI=1.2-2.1) were for risk. Allele D4S174-202 (P=0.001, OR=0.5, 95%CI=0.3-0.7) was restrictive. However, statistical significance was lost for all when corrected for multiple comparisons test. Our study could not affirm the genetic association within this region with NPC as did another pedigree study, but provide an opportunity for further gene discovery in this highly endemic NPC population and suggest that this region warrants further study.

Adolescent↗

Liquid chromatography-electrospray tandem mass spectrometry method for determination of indapamide in serum for single/multiple dose bioequivalence studies of sustained release formulations.

Indapamide and internal standard (5-chloro-2-methoxy-N-[2-(4-sulphamoylphenyl)ethyl]benzamide) were isolated from plasma by a single step liquid-liquid extraction in t-butyl methyl ether. The chromatographic separation was achieved on a reversed-phase C(18) monolithic column with a mobile phase consisting in a methanol/aqueous 0.1% formic acid mixture and a flow rate of 0.8 ml/min, in isocratic conditions, within 11 min. Target compounds were transferred in an ion trap analyzer via an atmospheric pressure electrospray interface (AP-ESI). The mass analyzer was used in a selected reaction monitoring (SRM) mode, in order to enhance on detection selectivity. Whole method produces quantitation limit for indapamide of 1 ng/ml. Method was successfully applied to assess bioequivalence of two sustained release marketed pharmaceutical formulations of indapamide 1.5 mg coated tablets, carried-out in a single/multiple doses, randomized design.

Antihypertensive Agents↗

Non-extractive procedure followed by LC/APCI MS/MS analysis of trimetazidine in plasma samples for assessing bioequivalence of immediate/modified release formulations.

Trimetazidine and internal standard [1-(2,4,5-trimethoxybenzyl)piperazine] were isolated from plasma by protein precipitation with trifluoroacetic acid. The neutralized supernatant was separated on a C(8) column with methanol-aqueous 0.11% triethylamine adjusted to pH 3.3 with formic acid (1:4, v/v) at a flow rate of 0.85 mL/min. The separation was achieved within 8 min and the column ef fluent was transferred into an ion trap analyzer via an atmospheric pressure chemical ionization interface. The mass analyzer was used in the selected reaction monitoring mode, to enhance detection selectivity. The method was fully validated with a quantitation limit for trimetazidine of 1.5 ng/mL. The method was successfully applied to assess bioequivalence of two immediate and two modified commercially available pharmaceutical formulations containing 20 and 35 mg of trimetazidine, respectively.

Atmospheric Pressure↗

A non-extracting procedure for the determination of meloxicam in plasma samples by HPLC-diode array detection.

The bioequivalence of two formulations of 15 mg tablets of meloxicam (CAS 71125-38-7), Meloxicam (LaborMed Pharma) and a commercially available preparation as reference in 24 healthy male and female Caucasian volunteers was assessed based on a validated non-extractive HPLC-DAD method. The sample preparation procedure was based on protein precipitation with a mixture of methanol/acetonitrile, trifluoacetic acid and sodium sulfate solution. Piroxicam (CAS 36322-90-4) was used as internal standard. The stepwise gradient elution profile of the chromatographic method allows injection of a high volume of the sample (500 microL) with the focusing of both analytes in a Chromolith Performance RP-18e column. The mobile phase constituents are methanol and aqueous 20 mmol/L Na2HPO4 buffer solution brought to pH = 6 with H3PO4. A flow-rate of 2 mL/min achieves a complete chromatographic run (including column equilibration) within 12 min. UV detection at 356 nm allowed a quantitation limit around 30 ng/mL. Bioequivalence study was based on an open-label, randomized, two-period, two-sequence, single dose, crossover design with a 2-week wash-out period between consecutive oral administrations. The main pharmacokinetic parameters (C(max), t(max), t 1/2, AUD and AUC(0-infinity)) were considered as evaluation criteria for the bioequivalence of the test drug against the reference.

Adolescent↗

Validated HPLC determination of 2-[(dimethylamino)methyl]cyclohexanone, an impurity in tramadol, using a precolumn derivatisation reaction with 2,4-dinitrophenylhydrazine.

A new method for the determination of 2-[(dimethylamino)methyl]cyclohexanone (DAMC) in Tramadol (as active substance or active ingredient in pharmaceutical formulations) is described. The method is based on the derivatisation of 2-[(dimethylamino)methyl]cyclohexanone with 2,4-dinitrophenylhydrazine (2,4-DNPH) in acidic conditions followed by a reversed-phase liquid chromatographic separation with UV detection. The method is simple, selective, quantitative and allows the determination of 2-[(dimethylamino)methyl]cyclohexanone at the low ppm level. The proposed method was validated with respect to selectivity, precision, linearity, accuracy and robustness.

Chromatography, High Pressure Liquid↗

Quantitative polymerase chain reaction-based assay for estimating DNA yield extracted from domestic cat specimens.

A quantitative polymerase chain reaction (PCR) assay has been developed for the quantification of genomic DNA extracted from domestic cat samples. The assay, which targets highly repetitive genomic short interspersed nuclear elements (SINE), can be performed rapidly and is highly sensitive, detecting as little as 10 fg of feline genomic DNA. The assay was linear over a 10(6) dilution range. We have recently developed a short tandem repeat (STR) multiplex panel for forensic analysis of feline specimens. The SINE assay is an integral part of the forensic typing system. The sensitivity of the assay will enable forensic examiners to determine the likelihood of success of genotyping sample extracts with the STR panel without sacrificing valuable DNA necessary to perform genotyping of samples.

Animals↗

Validation of a LC-fluorescence method for determination of free captopril in human plasma, using a pre-column derivatization reaction with monobromobimane.

Both derivatization of free captopril in human plasma samples using monobromobimane as fluorescent label and the corresponding HPLC-fluorescence detection (FLD) method were validated. Calibration curve for the fluorescent captopril derivative in plasma samples is linear in the ppb-ppm range with a detection limit of 4 ppb and an identification limit of 10 ppb (P%: 90; nu > or = 5). These methods were successfully applied on bioequivalence studies carried out on some marketed pharmaceutical formulations.

Angiotensin-Converting Enzyme Inhibitors↗