PubMed Health⌕ Search

Biomedical subjects

Victor Kosmopoulos

Publications and source records attributed to Victor Kosmopoulos.

6 recordsLinked to original sources

Inserting pedicle screws in the upper thoracic spine without the use of fluoroscopy or image guidance. Is it safe?

Several studies have looked at accuracy of thoracic pedicle screw placement using fluoroscopy, image guidance, and anatomical landmarks. To our knowledge the upper thoracic spine (T1-T6) has not been specifically studied in the context of screw insertion and placement accuracy without the use of either image guidance or fluoroscopy. Our objective was to study the accuracy of upper thoracic screw placement without the use of fluoroscopy or image guidance, and report on implant related complications. A single surgeon inserted 60 screws in 13 consecutive non-scoliotic spine patients. These were the first 60 screws placed in the high thoracic spine in our institution. The most common diagnosis in our patient population was trauma. All screws were inserted using a modified Roy-Camille technique. Post-operative axial computed tomography (CT) images were obtained for each patient and analyzed by an independent senior radiologist for placement accuracy. Implant related complications were prospectively noted. No pedicle screw misplacement was found in 61.5% of the patients. In the remaining 38.5% of patients some misplacements were noted. Fifty-three screws out of the total 60 implanted were placed correctly within all the pedicle margins. The overall pedicle screw placement accuracy was 88.3% using our modified Roy-Camille technique. Five medial and two lateral violations were noted in the seven misplaced screws. One of the seven misplaced screws was considered to be questionable in terms of pedicle perforation. No implant related complications were noted. We found that inserting pedicle screws in the upper thoracic spine based solely on anatomical landmarks was safe with an accuracy comparable to that of published studies using image-guided navigation at the thoracic level.

Adolescent↗

Observer reliability in evaluating pedicle screw placement using computed tomography.

Pedicle screw insertion in spinal surgery is a demanding technique with potential risks to neurological structures, for example, within the spinal canal. Assessing screw placement in clinical practice has been performed using plain radiographs and/or mainly axial computed tomography (CT) images. Screw placement using CT image reconstructions in multiple planes has been described, but its reliability has yet to be studied. This study aimed at addressing the clinical issue of interobserver and intraobserver reliability in the use of axial and coronal CT images for the assessment of pedicle screw placement. Fifty nine pedicle screws were studied by two experienced radiologists on two separate occasions. Screw placement was classified as "in", "out" or "questionable". On average, 88% and 92% of the screws were classified as "in" by the first and second radiologist, respectively. Intraobserver agreement strength was almost perfect for both observers using either axial or coronal images. Interobserver agreement strength was almost perfect (axial) and substantial (coronal) in the first reading and substantial (axial, coronal) in the second reading. Assessing screw placement in more than one CT imaging plane is not only useful but reliable. Routine use may enhance reporting quality of screw placement by surgeons and radiologists.

Adult↗

Computer tomography assessment of pedicle screw insertion in percutaneous posterior transpedicular stabilization.

Percutaneous insertion of cannulated pedicle screws has been recently developed as a minimally invasive alternative to the open technique during instrumented fusion procedures. Given the reported rate of screw misplacement using open techniques (up to 40%), we considered it important to analyze possible side effects of this new technique. Placement of 60 pedicle screws in 15 consecutive patients undergoing lumbar or lumbosacral fusion, mainly for spondylolisthesis, were analyzed. Axial, coronal, and sagittal reformatted computer tomography images were examined by three observers. Individual and consensus interpretation was obtained for each screw position. Along with frank penetration, we also looked at cortical encroachment of the pedicular wall by the screw. Thirteen percent of the patients (2/15) had severe frank penetration from the screws, while 80% of them (12/15) had some perforation. On axial images the incidence of severe frank pedicle penetration was 3.3% while the overall rate of screw perforation was 23%. In coronal images the overall screw perforation rate rose to 30% while the rate of severe frank pedicle penetration remained unchanged. One patient (6.6%) suffered S1 root symptoms due to a frankly medially misplaced screw, requiring re-operation. This study has shown that percutaneous insertion of cannulated pedicle screws in the lumbar spine is an acceptable procedure. The overall rate of perforation in axial images is below the higher rates reported in the literature but does remain important. Frank penetration of the pedicle was nevertheless low. It remains a demanding technique and has to be performed with extreme care to detail.

Bone Screws↗

Vertebroplasty and kyphoplasty affect vertebral motion segment stiffness and stress distributions: a microstructural finite-element study.

STUDY DESIGN: The mechanical behavior of a thoracic motion segment following cement augmentation was studied using the finite-element method. OBJECTIVE: To examine effects of cement augmentation on motion segment stiffness and load transfer. SUMMARY OF BACKGROUND DATA: Vertebroplasty and kyphoplasty procedures are meant to stiffen and strengthen the vertebral body, but the optimal cement volume and placement to achieve these goals without altering load transfer to adjacent segments are unknown. METHODS: A microstructural finite-element model of a vertebral motion segment was constructed from micro-CT images. Microdamage within the vertebral body trabecular structure was modeled using an elasto-plastic modulus reduction scheme. Three motion segment damage models were created: I = 18% apparent modulus reduction (least damage), II = 45%, and III = 85% (most damage); and several one- and two-segment polymethylmethacrylate cement repair strategies (partial fill kyphoplasty, replacement of bone and marrow; and both partial fill and complete fill vertebroplasty, replacement of marrow only) were studied. Average disc and bone stresses and motion segment apparent compressive stiffness were compared with baseline (undamaged and untreated) simulation results. RESULTS: In terms of maximizing stiffness and minimizing stress alterations in the adjacent vertebral body and increasing motion segment apparent stiffness, we found that, other than complete fill, the most effective single-segment cement repair strategy was vertebroplasty on the periphery of the superior segment overlying the disc anulus (<0.1% overall vertebral body bone stress alteration and 83% stiffness increase, respectively, damage Model III). Two-segment vertebroplasty (all repair models) restored motion segment stiffness to baseline levels in all damage models, while single-segment vertebroplasty (all repair models) restored stiffness to baseline levels only in damage Model I. Single- and two-segment kyphoplasty was effective in restoring stiffness to baseline levels for Model I only. Compared with the baseline model, cement augmentation decreased average treated segment bone stresses (up to 66%, complete fill vertebroplasty elasto-plastic modulus reduction Model III), increased average intervertebral disc nucleus stresses (up to 59%, kyphoplasty elasto-plastic modulus reduction Model III), and increased average adjacent segment, endplate region stresses (up to 2.8%, kyphoplasty elasto-plastic modulus reduction Model II). Adjacent (untreated) segment peak bone stresses were increased (up to 45%, kyphoplasty, Model III) in endplate regions underlying the intervertebral disc nucleus. CONCLUSIONS: The damage-repair simulations indicated that cement augmentation improves motion segment stiffness but substantially alters bone stress distributions in treated and adjacent segments.

Aged↗

Prevention of hip lag screw cut-out by cement augmentation: description of a new technique and preliminary clinical results.

Cement augmentation of hip lag screws to avoid cut-out displacement is classically described, along with a number of technical drawbacks. In a series of six elderly patients with hip fractures in osteoporotic bone, we illustrate catheter-assisted delivery of limited amounts of a new bisphenol-a-glycidyl dimethacrylate (bis-GMA)-based composite into hip compression screw threads, enabling significant increase in insertional torque compared with unaugmented screws. In two patients, unaugmented screws that did not initially purchase were tightened with a minimum torque of 1 N-m after augmenting with bis-GMA-based composite. No screw or femoral head displacement relative to baseline (2 days postoperative) was seen in any patient on serial x-rays taken up to 6 months after surgery. This technique adds approximately 10 minutes to surgery time. Advantages of bis-GMA-based composite over traditional PMMA augmentation include mixing on-demand, the ability to make repeated injections over extended periods in the event of femoral head perforations (in one patient in this series), precise placement of adequately small volumes of material, and a lower exotherm. Potentially, this bis-GMA-based composite may reduce the frequency of cut-out complications by enhancing bone-implant interface.

Aged↗

Finite element modeling of trabecular bone damage.

This paper presents a finite element-based, computational model for analysis of structural damage to trabecular bone tissues. A modulus reduction method was formulated from elasto-plasticity theory, and was used to account for site-specific trabecular bone tissue damage. Trabecular bone tissue damage is illustrated using a large-scale, anatomically accurate, two-dimensional, microstructural finite element model of a human thoracic vertebral body. Four models with varying specifications for damage accumulation were subjected to compressive loading and unloading cycles. The numerical results and experimental validation demonstrated that the modulus reduction method reproduced the non-linear mechanical behaviour of vertebal trabecular bone. The iterative computational approach presented provides a methodology to study trabecular bone damage, and should provide researchers with a computational approach to study bone fracture and repair and to predict vertebral fragility.

Aged↗