PubMed Health⌕ Search

Biomedical subjects

Vijay K Chaudhary

Publications and source records attributed to Vijay K Chaudhary.

7 recordsLinked to original sources

Bifunctional recombinant fusion proteins for rapid detection of antibodies to both HIV-1 and HIV-2 in whole blood.

BACKGROUND: Availability of accurate diagnostic tests has been helpful in curtailing the spread of HIV infection. Among these, simple, point of care, inexpensive tests which require only a drop of blood from finger-prick and give reliable results within minutes are a must for expansion of testing services and for reaching mobile and marginalized populations. Such tests will not only be a boon for the infrastructure-starved developing and underdeveloped countries but will also be extremely useful in developed countries where post-testing compliance is a major problem. Our laboratory has been involved in developing reagents for heamagglutination-based rapid detection of antibodies to HIV in whole blood using recombinant molecules specific for either HIV-1 or HIV-2. Since it is not required of a screening test to differentially detect HIV and HIV-2, it would useful to create a single molecule capable of simultaneous detection of both HIV-1 and HIV-2 in a drop of blood. RESULTS: The present paper describes designing, high-level expression and large-scale purification of new molecules comprising recombinant anti-RBC Fab fused to immunodominant regions of envelope sequences from both gp41 of HIV-1 and gp36 of HIV-2. These immunodominant regions of HIV envelope contain cysteine residues, which make disulfide bond and can interfere with the assembly of light chain and heavy chain fragment to make Fab molecule in vitro. To circumvent this problem, a series of fusion proteins having different combinations of native and mutant envelope sequences were constructed, purified and evaluated for their efficacy in detecting antibodies to HIV-1 and HIV-2. A chimeric molecule comprising native envelope sequence of gp41 of HIV-1 and modified envelope sequence of gp36 of HIV-2 gave good production yield and also detected both HIV-1 and HIV-2 samples with high sensitivity and specificity. CONCLUSION: The new bifunctional antibody fusion protein identified in this study detects both HIV-1 and HIV-2 infected samples efficiently and can be used in place of molecules that detect only HIV-1 or HIV-2. This will make reagent production more economical as only one molecule has to be produced in place of two molecules. Also, it will simplify the testing procedure allowing detection of both HIV-1 and HIV-2 infections in a single drop of blood.

Antibodies, Bispecific↗

Expression and purification of recombinant 38-kDa and Mtb81 antigens of Mycobacterium tuberculosis for application in serodiagnosis.

Availability of genome sequence of Mycobacterium tuberculosis has accelerated identification of antigens for serodiagnosis of tuberculosis and a number of new antigens are being tested in various combinations to produce cocktails with high sensitivity and specificity. For producing a highly specific diagnostic test, it is important that the recombinant antigens be highly pure, free of host protein, and correctly folded so that they bind only to specific antibodies. Also, for commercial viability they need to be produced in high yields. We have cloned, expressed, and purified a number of mycobacterial antigens in Escherichia coli. This paper describes, expression and purification of two important mycobacterial proteins with serodiagnostic potential, namely, 38-kDa and Mtb81 antigens, in monomeric form. The protocol involves using a T7 promoter based expression vector under conditions of regulated and slow expression followed by three-step column chromatography procedure to obtain highly purified proteins. The yields of the two proteins were several folds higher than previously reported. The purified proteins were useful in detecting antibodies in sera of tuberculosis patients (smear positive, smear negative, and extra-pulmonary categories).

Antigens, Bacterial↗

Expression and purification of recombinant antigens of Mycobacterium tuberculosis for application in serodiagnosis.

Accurate diagnosis is essential for the treatment, prevention, and control of tuberculosis. Poor specificity of the tuberculin skin test in BCG-vaccinated populations and constraints to implementation of PCR and CMI-based diagnostic assays in developing countries warrant development of easy-to perform robust serological tests. Due to great heterogeneity in humoral response in TB patients, it will be necessary to include several antigens in any diagnostic assay to achieve useful levels of sensitivity and specificity. This needs production of recombinants, soluble versions of mycobacterial antigens in high yields. We have cloned, expressed, and purified a number of mycobacterial proteins in Escherichia coli. This paper describes the expression and purification of four promising sero-reactive proteins namely, ESAT6, CFP10, MTC28, and 14-kDa antigen of Mycobacterium tuberculosis. The protocol involves regulated and slow expression of proteins by using a T7 promoter-based expression vector for obtaining soluble protein followed by a three-step column chromatography procedure employing media with high binding capacity and flow characteristics. The yields of these proteins obtained were several folds higher than previously reported. The purified proteins were useful in detecting antibodies in sera of TB patients (smear positive, smear negative, and extra-pulmonary categories) and in combination with other immunodominant antigens will be useful in increasing the sensitivity to detect M. tuberculosis specific antibodies.

Antibodies, Bacterial↗

High-density functional display of proteins on bacteriophage lambda.

We designed a bacteriophage lambda system to display peptides and proteins fused at the C terminus of the head protein gpD of phage lambda. DNA encoding the foreign peptide/protein was first inserted at the 3' end of a DNA segment encoding gpD under the control of the lac promoter in a plasmid vector (donor plasmid), which also carried lox P(wt) and lox P(511) recombination sequences. Cre-expressing cells were transformed with this plasmid and subsequently infected with a recipient lambda phage that carried a stuffer DNA segment flanked by lox P(wt) and lox P(511) sites. Recombination occurred in vivo at the lox sites and Amp(r) cointegrates were formed. The cointegrates produced recombinant phage that displayed foreign protein fused at the C terminus of gpD. The system was optimised by cloning DNA encoding different length fragments of HIV-1 p24 (amino acid residues 1-72, 1-156 and 1-231) and the display was compared with that obtained with M13 phage. The display on lambda phage was at least 100-fold higher than on M13 phage for all the fragments with no degradation of displayed products. The high-density display on lambda phage was superior to that on M13 phage and resulted in selective enrichment of epitope-bearing clones from gene-fragment libraries. Single-chain antibodies were displayed in functional form on phage lambda, strongly suggesting that correct disulphide bond formation takes place during display. This lambda phage display system, which avoids direct cloning into lambda DNA and in vitro packaging, achieved cloning efficiencies comparable to those obtained with any plasmid system. The high-density display of foreign proteins on bacteriophage lambda should be extremely useful in studying low-affinity protein-protein interactions more efficiently compared to the M13 phage-based system.

Bacteriophage M13↗

Whole-blood agglutination assay for on-site detection of human immunodeficiency virus infection.

Simple and rapid diagnostic tests are needed to curtail human immunodeficiency virus (HIV) infection, especially in the developing and underdeveloped nations of the world. The visible-agglutination assay for the detection of HIV with the naked eye (NEVA HIV, which represents naked eye visible-agglutination assay for HIV) is a hemagglutination-based test for the detection of antibodies to HIV in whole blood. The NEVA HIV reagent is a cocktail of highly stable recombinant bifunctional antibody fusion proteins with HIV antigens which can be produced in large quantities with a high degree of purity. The test procedure involves mixing of one drop of the NEVA HIV reagent with one drop of blood sample on a glass slide. The presence of anti-HIV antibodies in the blood sample leads to clumping of erythrocytes (agglutination) that can be seen with the naked eye. Evaluation with commercially available panels of sera and clinical samples has shown that the performance of NEVA HIV is comparable to those of U.S. and European Food and Drug Administration-approved rapid as well as enzyme-linked immunosorbent assay kits. The test detects antibodies to both HIV type 1 (HIV-1) and HIV-2 in a single spot and gives results in less than 5 min. The test was developed by keeping in mind the practical constraints of testing in less developed countries and thus is completely instrument-free, requiring no infrastructure or even electricity. Because the test is extremely rapid, requires no sample preparation, and is simple enough to be performed by a semiskilled technician in any remote area, NEVA HIV is a test for the hard-to-reach populations of the world.

Antibodies, Monoclonal↗

Expression, purification, and characterization of an anti-RBCFab-p24 fusion protein for hemagglutination-based rapid detection of antibodies to HIV in whole blood.

A fusion protein A41Fabp246 consisting of Fab of an anti-RBC MAb A41 and amino acids 8-153 of HIV-1 p24 (p246) fused at the C-terminus of A41Fd was purified following assembly of A41Fdp246 with A41 LC in vitro, using a denaturation- renaturation protocol and a 4-step column chromatography procedure. The highly purified, monomeric A41Fabp246 was then evaluated for hemagglutination-based detection of anti-p24 antibodies using sera from HIV-infected individuals. This derivative of p24 is devoid of maximum homology region and the C-terminal domain of p24, which is responsible for oligomerization of p24, but retains full complement of immunodominant epitopes. This new fusion protein in combination with fusion proteins consisting of monovalent fragment of another anti-human RBC antibody fused to immunodominant regions of envelope glycoproteins of HIV-1 and HIV-2 should be useful in preparing a cocktail of reagents for highly sensitive detection of anti-HIV antibodies in whole blood.

Animals↗

Identification of cross-reactive proteins amongst different Curvularia species.

BACKGROUND: Curvularia lunata is an important inhalant allergen. The present study was undertaken to investigate the shared IgG- and IgE-binding components among seven Curvularia species prevalent in the aerospora. METHODS: Seven different Curvularia species were grown in a semisynthetic medium for 13 days. The extracts were analyzed by SDS-PAGE, immunoblot and ELISA/immunoblot inhibition using sera from C. lunata-positive patients and anti-C. lunata rabbit serum. RESULTS: Different Curvularia species showed 11-19 protein bands on SDS-PAGE. Proteins of 12, 20, 31, 45, 53, 78 and 97 kD were present in all the species. Eight out of 98 nasobronchial patients exhibited positive skin tests to C. lunata and to at least five Curvularia species. ELISA using these sera showed IgE binding with Curvularia species. Immunoblot using pooled anti-C. lunata sera from patients showed 5-12 allergenic proteins. Proteins of 12, 31, 45, 53 and 78 kD showed IgE binding in Curvularia species. Antibodies against C. lunata detected 6-14 antigenic proteins on immunoblot. Proteins of 31, 45 and 53 kD showed IgG binding in all the species. Proteins of 31 and 53 kD showed complete IgE/IgG binding inhibition. IgE/IgG ELISA inhibition showed dose-dependent inhibition in Curvularia species. C. lunata extract required 0.17 and 0.11 microg of protein for 50% IgE and IgG inhibition, respectively. C. clavata and C. pallescens required 10 times more protein to exhibit the same inhibition and other species required similar protein levels as those required by C. lunata. CONCLUSIONS: A high degree of cross-reactivity was observed between C. lunata and the six other Curvularia species tested. C. lunata and C. senegalensis shared maximum allergenic and antigenic components.

Allergens↗