PubMed Health⌕ Search

Biomedical subjects

Viktor Sebestyén Varga

Publications and source records attributed to Viktor Sebestyén Varga.

3 recordsLinked to original sources

Automated four-color analysis of leukocytes by scanning fluorescence microscopy using quantum dots.

BACKGROUND: Scanning fluorescence microscope (SFM) is a new technique for automated motorized microscopes to measure multiple fluorochrome labeled cells (Bocsi et al., Cytometry A 2004, 61:1-8). AIMS: We developed a four-color staining protocol (DNA, CD3, CD4, and CD8) for the lymphocyte phenotyping by SFM. METHODS: Organic (Alexa488, FITC, PE-Alexa610, CyChrom, APC) and inorganic (quantum dot (QD) 605 or 655) fluorochromes were used and compared in different combinations. Measurements were performed in suspension by flow cytometer (FCM) and on slide by SFM. RESULTS: Both QDs were detectable by the appropriate Axioplan-2 and FCM filters and the AxioCam BW-camera. CD4/CD8 ratios were highly correlated (P = 0.01) between the SFM and FCM. CONCLUSION: Automated SFM is an applicable tool for CD4/CD8 ratio determination in peripheral blood samples with QDs.

Benzimidazoles↗

Scanning fluorescent microscopy is an alternative for quantitative fluorescent cell analysis.

BACKGROUND: Fluorescent measurements on cells are performed today with FCM and laser scanning cytometry. The scientific community dealing with quantitative cell analysis would benefit from the development of a new digital multichannel and virtual microscopy based scanning fluorescent microscopy technology and from its evaluation on routine standardized fluorescent beads and clinical specimens. METHODS: We applied a commercial motorized fluorescent microscope system. The scanning was done at 20 x (0.5 NA) magnification, on three channels (Rhodamine, FITC, Hoechst). The SFM (scanning fluorescent microscopy) software included the following features: scanning area, exposure time, and channel definition, autofocused scanning, densitometric and morphometric cellular feature determination, gating on scatterplots and frequency histograms, and preparation of galleries of the gated cells. For the calibration and standardization Immuno-Brite beads were used. RESULTS: With application of shading compensation, the CV of fluorescence of the beads decreased from 24.3% to 3.9%. Standard JPEG image compression until 1:150 resulted in no significant change. The change of focus influenced the CV significantly only after +/-5 microm error. CONCLUSIONS: SFM is a valuable method for the evaluation of fluorescently labeled cells.

Fluorescent Dyes↗

Scanning fluorescent microscopy analysis is applicable for absolute and relative cell frequency determinations.

BACKGROUND: Flow cytometry (FCM) and laser scanning cytometry (LSC) are the routine techniques for fluorescent cell analysis. Recently, we developed a scanning fluorescent microscopy (SFM) technique. This study compares SFM to LSC (two slide-based cytometry, SBC, techniques) and FCM, in experimental and clinical settings. METHODS: For the relative cell-frequency determinations, HT29 colorectal cancer cells and Ficoll separated blood mononuclear cells (FSBMCs) were serially diluted (from 1:1 to 1:1,000) and measured by each of the three techniques. For the absolute cell number determinations (only for SBC) FSBMCs were smeared on slides, then HT29 cells were placed on the slide with a micromanipulator (5-50 cells). Tumor cells circulating in the peripheral blood were isolated by magnetic separation from clinical blood samples of colorectal cancer patients. All samples were double-stained by CD45 ECD and CAM5.2 FITC antibodies. For slides, TOTO-3 and Hoechst 33258 DNA dyes were applied as nuclear counter staining. RESULTS: In the relative cell frequency determinations, the correlations between the calculated value and measured values by SFM, LSC, and FCM were r(2) = 0.79, 0.62, and 0.84, respectively (for all P < 0.01). In the absolute cell frequency determinations, SFM and LSC correlated to a high degree (r(2) = 0.97; P < 0.01). CONCLUSIONS: SFM proved to be a reliable alternative method, providing results comparable to LSC and FCM. SBC proved to be more suitable for rare-cell detection than FCM. SFM with digital slides may prove an acceptable adaptation of conventional fluorescent microscopes in order to perform rare-cell detection.

Antiporters↗