PubMed Health⌕ Search

Biomedical subjects

Vincent Duval

Publications and source records attributed to Vincent Duval.

3 recordsLinked to original sources

Optimal blood sampling time windows for parameter estimation using a population approach: design of a phase II clinical trial.

The objective of this paper is to determine optimal blood sampling time windows for the estimation of pharmacokinetic (PK) parameters by a population approach within the clinical constraints. A population PK model was developed to describe a reference phase II PK dataset. Using this model and the parameter estimates, D-optimal sampling times were determined by optimising the determinant of the population Fisher information matrix (PFIM) using PFIM_ _M 1.2 and the modified Fedorov exchange algorithm. Optimal sampling time windows were then determined by allowing the D-optimal windows design to result in a specified level of efficiency when compared to the fixed-times D-optimal design. The best results were obtained when K(a) and IIV on K(a) were fixed. Windows were determined using this approach assuming 90% level of efficiency and uniform sample distribution. Four optimal sampling time windows were determined as follow: at trough between 22 h and new drug administration; between 2 and 4 h after dose for all patients; and for 1/3 of the patients only 2 sampling time windows between 4 and 10 h after dose, equal to [4 h-5 h 05] and [9 h 10-10 h]. This work permitted the determination of an optimal design, with suitable sampling time windows which was then evaluated by simulations. The sampling time windows will be used to define the sampling schedule in a prospective phase II study.

Administration, Oral↗

Impact of omission or replacement of data below the limit of quantification on parameter estimates in a two-compartment model.

PURPOSE: To evaluate the influence of omission and replacement approaches for data below the limit of quantification (LOQ) on the estimation of pharmacokinetic parameters for two-compartment models when using nonlinear mixed-effect models. METHOD: Nine data sets were simulated according to a two-compartment intravenous bolus model with interindividual and residual variabilities, and a sparse sampling strategy was adopted. The data sets differed with respect to area-under-the-curve (AUC) ratio (0.1. 0.2, 0.3) and half-life ratio (0.03, 0.1, 0.3) between the distribution and elimination phases. For each of the nine data sets, six reduced data sets were created by omitting 5%, 10%, 20%, 30%, 40%, or 50% of the lowest concentration values. For each of the reduced data sets only one simple correction procedure to handle observations below LOQ was applied. All the values below the LOQ were deleted, and the first one was replaced by half of the LOQ value. Population parameters were estimated for each of the 117 resulting data sets (one initial, six reduced, and six "corrected" data sets for each of the nine cases). This approach was also applied on a real data set of patients administered multiple i.v. bolus doses. RESULTS: For many of the data sets, particularly when a large fraction of the data was omitted, one or several population parameters were biased. When there was bias, clearance (CL) usually was underestimated, whereas peripheral volume was overestimated. The parameters related to the distribution phase (central volume and intercompartmental clearance) were less affected, and changes were not systematic. The correction procedure markedly decreased overall bias on the fixed effect of the parameters. Results for the real data were similar. CONCLUSION: Omission of data below the LOQ value may induce a not negligible bias on fixed-effect parameter estimates. The influence of the omission of values below LOQ was related to the underlying shape of the concentration-time profile and fraction of omitted observations. The use of a simple replacement rule seems to reduce this bias in estimates but needs further investigation.

Models, Theoretical↗

Physiologically based model of acute ischemic stroke.

In the treatment of acute ischemic stroke most of the clinical trials have failed, contrasting with promising results in the preclinical stages. This continuing discrepancy suggests some misconceptions in the understanding of acute ischemic stroke. One possible method for identifying the shortcomings of present-day approaches is to integrate all the available knowledge into a single mathematical model and to subject that model to challenges via simulations with available experimental data. As a first stage, then, the authors developed a simplified model, defining the structure and the different parameters that represent the phenomena that occur during the hyperacute phase of ischemic stroke. First, the different critical points of the evolution of ischemic stroke, based on the available evidence on the pathophysiology of stroke, were identified. Those key steps were then related to the quantitative data obtained by magnetic resonance imaging and positron emission tomography scan. These two techniques allow the measurement of diverse key markers of cerebral metabolism: cerebral blood flow (CBF), oxygen extraction factor, cerebral metabolism rate of oxygen, and the apparent diffusion coefficient of water, among others. Those markers were organized together through mathematical equations, and changed over time in order to describe the evolution of an acute ischemic stroke. At each time during the evolution of stroke those parameters are summarized in a parameter called survival delay. This parameter made possible the definition of three different states for tissues-functional, infarcted, salvageable-as end point. Once the model was designed, simulations were performed to explore its internal validity. Simulation results were consistent with the reality of acute ischemic stroke and did not reveal any major drawbacks in the use of the model. The more rapid the decrease in CBF, the larger is the final infarcted area. The model also allowed for the characterization of two types of tissue in the penumbra: tissues with an initial metabolic impairment and tissues altered owing to the closeness of the ischemic area. The results of this experiment were consistent with what is known of acute ischemic stroke. The model integrated different markers of acute ischemic stroke into a single entity in order to mimic acute ischemic stroke, and has been shown to have a reasonable degree of internal validity.

Animals↗