PubMed Health⌕ Search

Biomedical subjects

Vincent Gau

Publications and source records attributed to Vincent Gau.

4 recordsLinked to original sources

Point-of-care biosensor systems for cancer diagnostics/prognostics.

With the growing number of fatalities resulting from the 100 or so cancer-related diseases, new enabling tools are required to provide extensive molecular profiles of patients to guide the clinician in making viable diagnosis and prognosis. Unfortunately with cancer-related diseases, there is not one molecular marker that can provide sufficient information to assist the clinician in making effective prognoses or even diagnoses. Indeed, large panels of markers must typically be evaluated that cut across several different classes (mutations in certain gene fragments--DNA; over/under-expression of gene activity as monitored by messenger RNAs; the amount of proteins present in serum or circulating tumor cells). The classical biosensor format (dipstick approach for monitoring the presence of a single element) is viewed as a valuable tool in many bioassays, but possesses numerous limitations in cancer due primarily to the single element nature of these sensing platforms. As such, if biosensors are to become valuable tools in the arsenal of the clinician to manage cancer patients, new formats are required. This review seeks to provide an overview of the current thinking on molecular profiling for diagnosis and prognosis of cancers and also, provide insight into the current state-of-the-art in the biosensor field and new strategies that must be considered to bring this important technology into the cancer field.

Biomarkers, Tumor↗

Use of electrochemical DNA biosensors for rapid molecular identification of uropathogens in clinical urine specimens.

We describe the first species-specific detection of bacterial pathogens in human clinical fluid samples using a microfabricated electrochemical sensor array. Each of the 16 sensors in the array consisted of three single-layer gold electrodes-working, reference, and auxiliary. Each of the working electrodes contained one representative from a library of capture probes, each specific for a clinically relevant bacterial urinary pathogen. The library included probes for Escherichia coli, Proteus mirabilis, Pseudomonas aeruginosa, Enterocococcus spp., and the Klebsiella-Enterobacter group. A bacterial 16S rRNA target derived from single-step bacterial lysis was hybridized both to the biotin-modified capture probe on the sensor surface and to a second, fluorescein-modified detector probe. Detection of the target-probe hybrids was achieved through binding of a horseradish peroxidase (HRP)-conjugated anti-fluorescein antibody to the detector probe. Amperometric measurement of the catalyzed HRP reaction was obtained at a fixed potential of -200 mV between the working and reference electrodes. Species-specific detection of as few as 2,600 uropathogenic bacteria in culture, inoculated urine, and clinical urine samples was achieved within 45 min from the beginning of sample processing. In a feasibility study of this amperometric detection system using blinded clinical urine specimens, the sensor array had 100% sensitivity for direct detection of gram-negative bacteria without nucleic acid purification or amplification. Identification was demonstrated for 98% of gram-negative bacteria for which species-specific probes were available. When combined with a microfluidics-based sample preparation module, the integrated system could serve as a point-of-care device for rapid diagnosis of urinary tract infections.

Biosensing Techniques↗

Electrochemical molecular analysis without nucleic acid amplification.

Electrochemical biosensors have revolutionized glucose monitoring but have not yet fulfilled their promise of a low cost, direct detection replacement for genetic amplification tests such as PCR [K. Kerman, M. Kobayashi, E. Tamiya, Recent trends in electrochemical DNA biosensor technology, Meas. Sci. Technol. 15 (2004) R1-R11; A. Chaubey, B.D. Malhotra, Mediated biosensors. Biosens. Bioelectron. 17 (6-7) (2002) 441-456]. It has been anticipated that the integration of nanoscale chemical structures such as self-assembled monolayers with electrochemical biosensors would increase sensitivity by decreasing inherent system noise. We have designed a novel biosensing approach incorporating such integration and achieved rapid, ultra-low concentration sensitivities without target amplification. Raw samples are mixed with lysis buffer to allow hybridization of nucleic acid targets with anchor and signal probes before immobilizing a signaling enzyme proximate to the biosensor surface. A bias potential is subsequently applied and the secondary byproduct of a cyclic peroxidase reaction measured. Further studies have demonstrated the application of our approach in protein, clinical chemistry, and ionic assays.

Biosensing Techniques↗

Rapid, species-specific detection of uropathogen 16S rDNA and rRNA at ambient temperature by dot-blot hybridization and an electrochemical sensor array.

Development of rapid molecular approaches for pathogen detection is key to improving treatment of infectious diseases. For this study, the kinetics and temperature-dependence of DNA probe hybridization to uropathogen species-specific sequences were examined. A set of oligonucleotide probes were designed based on variable regions of the 16S gene of the Escherichia coli, Proteus mirabilis, Klebsiella oxytoca, and Pseudomonas aeruginosa. A universal bacterial probe and probes-specific for gram-positive and gram-negative organisms were also included. The oligonucleotide probes discriminated among 16S genes derived from 11 different species of uropathogenic bacteria applied to nylon membranes in a dot-blot format. Significant binding of oligonucleotide probes to target DNA and removal of nonspecific binding by membrane washing could both be achieved rapidly, requiring as little as 10 min. An oligonucleotide probe from the same species-specific region of the E. coli 16S gene was used as a capture probe in a novel electrochemical 16-sensor array based on microfabrication technology. Sequence-specific hybridization of target uropathogen 16S rDNA was detected through horseradish peroxidase acting as an electrochemical transducer via a second, detector probe. The sensor array demonstrated rapid, species-specific hybridization in a time course consistent with the rapid kinetics of the dot-blot hybridization studies. As in the dot-blot hybridization studies, species-specific detection of bacterial nucleic acids using the sensor array approach was demonstrated both at 65 degrees C and at room temperature. These results demonstrate that molecular hybridization approaches can be adapted to rapid, room temperature conditions ideal for an electrochemical sensor array platform.

Bacteria↗