PubMed Health⌕ Search

Biomedical subjects

Vincent Israel-Jost

Publications and source records attributed to Vincent Israel-Jost.

2 recordsLinked to original sources

Pinhole SPECT imaging: compact projection/backprojection operator for efficient algebraic reconstruction.

We describe the efficient algebraic reconstruction (EAR) method, which applies to cone-beam tomographic reconstruction problems with a circular symmetry. Three independant steps/stages are presented, which use two symmetries and a factorization of the point spread functions (PSFs), each reducing computing times and eventually storage in memory or hard drive. In the case of pinhole single photon emission computed tomography (SPECT), we show how the EAR method can incorporate most of the physical and geometrical effects which change the PSF compared to the Dirac function assumed in analytical methods, thus showing improvements on reconstructed images. We also compare results obtained by the EAR method with a cubic grid implementation of an algebraic method and modeling of the PSF and we show that there is no significant loss of quality, despite the use of a noncubic grid for voxels in the EAR method. Data from a phantom, reconstructed with the EAR method, demonstrate 1.08-mm spatial tomographic resolution despite the use of a 1.5-mm pinhole SPECT device and several applications in rat and mouse imaging are shown. Finally, we discuss the conditions of application of the method when symmetries are broken, by considering the different parameters of the calibration and nonsymmetric physical effects such as attenuation.

Algorithms↗

Assessment of left ventricular perfusion, volumes, and motion in mice using pinhole gated SPECT.

UNLABELLED: Quantitative functional normal data should be a prerequisite before applying SPECT in murine models of cardiac disease. Therefore, we investigated the capability of in vivo pinhole gated SPECT for establishment of a reference database for left ventricular myocardial perfusion, volumes, and motion in normal mice. METHODS: A small-animal dedicated pinhole gamma-camera with a field of view of 17 cm and a focal distance of 12 cm was used with a 1.5-mm pinhole and a 2.5-cm radius of rotation. Phantoms were designed to test spatial resolution and microvolume measurements of accuracy. Eight adult normal mice (CD1) were studied using a heated mixture of air (0.3 L/min) and 1.5%-2.5% isoflurane for anesthesia. For myocardial perfusion, 350-450 MBq of (99m)Tc-tetrofosmin were used in 0.15-0.25 mL. Gated acquisitions (8 or 10 time bins per cardiac cycle) were obtained using a 180 degrees circular arc and 48 anterior projections of 300 R-R intervals. Image reconstruction was done using a specific Algebraic Reconstruction Technique (ART) cone-beam algorithm. For quantification, reconstructed images were processed using standard nuclear medicine software. RESULTS: Millimetric spatial resolution and volume calibration linear relationships (r(2) = 0.99) in the 10- to 100-muL range were obtained in phantoms and used to scale in vivo volume values. In mice, left ventricular perfusion was lower in the apex (65% +/- 6%) versus lateral (72% +/- 5%), inferior (74% +/- 5%), septum (75% +/- 4%), and anterior (74% +/- 2%) walls. The left ventricular ejection fraction was 60% +/- 9%, end-diastolic volume was 50 +/- 8 muL, end-systolic volume was 20 +/- 6 muL, stroke volume was 29.5 +/- 6 muL, and cardiac output was 9.6 +/- 1.6 mL/min. Wall thickening was higher in the apex (47% +/- 12%) versus lateral (30% +/- 9%), inferior (33% +/- 8%), septum (37% +/- 10%), and anterior (33% +/- 10%) walls. CONCLUSION: This work shows that in vivo pinhole gated SPECT can be used for assessment of left ventricular perfusion, volumes, and cardiac function in normal mice.

Animals↗