PubMed Health⌕ Search

Biomedical subjects

Vincent Pichot

Publications and source records attributed to Vincent Pichot.

22 records · Page 2Linked to original sources

Cardiac interbeat interval increment for the identification of obstructive sleep apnea.

The prevalence of obstructive sleep apnea syndrome (OSAS) is high in developed countries but its diagnosis is costly. Based on physiological evidence, the frequency component of heart rate variability (HRV) was evaluated as a simple and inexpensive diagnostic tool in OSAS. The predictive accuracy of frequency-domain HRV variables obtained from 24-hour ECG Holter monitoring (the power spectral density of the interbeat interval increment of very low frequencies, "VLFIpsd," and its percentage over the total power spectral density, "% VLFI"), and of established time-domain HRV variables were analyzed by comparison with respiratory disturbances indexes assessed by complete polysomnography in 124 consecutive patients (98 men aged 53.8 +/- 11.2 years) with clinically suspected OSAS. OSAS was present in 54 (43.5%) patients according to standard criteria. Using receiver operating characteristic curve analysis, two of the three most powerful predictors were frequency-domain variables: % VLFI (W = 0.80, P < 0.0001), and VL-FIpsd (W = 0.79, P < 0.0001). Using a multiple logistic regression analysis, %VLFI was the most strongly associated with diseased status (adjusted OR: 8.4; 95% CI: 3.4-19.5). Using an appropriate threshold, %VLFI demonstrated a diagnostic sensitivity of 87%. A 3-month continuous positive airway pressure treatment significantly improved the same parameter. Frequency-domain analysis of the interbeat interval increment appears as a powerful tool for OSAS diagnosis and follow-up. The simplicity of its analysis and of its use makes of it a well-suited variable for mass screening of OSAS patients.

Adult↗

Frequent and prolonged asymptomatic episodes of paroxysmal atrial fibrillation revealed by automatic long-term event recorders in patients with a negative 24-hour Holter.

The presence, frequency, and duration of episodes of paroxysmal atrial fibrillation (PAF) is difficult to establish. This is caused by the limited duration of standard Holter recordings and to the unsatisfactory yield of patient-triggered event recorders, because of asymptomatic events and of an inconsistent use of the patient dependent triggering function. A prospective cohort of 65 consecutive patients with recurrent palpitations and a negative 24-hour ECG Holter was investigated by means of a cardiac event recorder bearing continuous automatic arrhythmia analysis and storage. Over a mean duration of 77 +/- 36 hours, episodes of PAF were diagnosed in 20 (31%) patients, who had a total of 37 episodes; mean duration of PAF episodes was 7 hours 50 minutes +/- 8/hours 45 minutes (minimum 45 minutes, maximum 28 hours). Eleven (55%) of these 20 patients were asymptomatic and would have remained undiagnosed without the automatic mode of the event recorder. Asymptomatic PAF episodes were longer than symptomatic ones (10 hours 30 minutes +/- 6 hours 30 minutes vs 4 hours 50 minutes +/- 4 hours, P < 0.05). In addition, episodes of sustained paroxysmal supraventricular tachycardia (PSVT) were diagnosed in 39 (57%) patients, of whom 34 (87%) were symptomatic. In this prospective cohort, a second standard 24-hour monitoring would have missed 44% of the patients with PAF or PSVT and a classical patient-triggered event recorder 13%. In patients still complaining of palpitations after one negative 24-hour Holter, numerous, prolonged, and often asymptomatic episodes of PAF can be revealed by long-term automatic event recorders. These devices should help clarify the clinical consequences of such episodes.

Atrial Fibrillation↗

Cardiac baroreflex control in humans during and immediately after brief exposure to simulated high altitude.

To examine the baroreflex response in humans during and immediately after acute hypoxia exposure, the cardiac baroreflex sensitivity (BRS) was studied using adaptation of RR intervals in response to spontaneous systolic blood pressure fluctuations (sequences methodology) in 11 unacclimatized subjects. All measurements were made under fixed breathing rate, and realized consecutively at baseline level (20 min), at an inspired oxygen concentration of 11% (15 min) and again under normoxic conditions (20 min; recovery period). The spontaneous baroreflex response decreases progressively during hypoxic exposure, causing a tachycardic response at this FiO2 without any significant alteration of the systolic or diastolic blood pressure. The magnitude of decrease for this variable at the end of exposure averaged 42.9 +/- 15.6%. The simultaneous spectral analysis of heart rate (HR) variability in hypoxic condition confirmed an alteration in the parasympathetic activity (HFnu: -17.8 +/- 30.9% versus basal conditions, P < 0.01) counterbalanced by an exaggerated sympathetic activity (LFnu: +33 +/- 42.4%, P < 0.05) at the sinus node. Interestingly, we could observe an enhanced cardiac baroreflex response during the period following the inhalation of the hypoxic mixture (+130.6 +/- 15.6% of basal conditions, P < 0.001). There is a relationship with a significant and abrupt increase in the parasympathetic control of HR (mean HR reached 111 +/- 8.1% of the mean basal HR, P < 0.01). These results suggest that brief exposure to hypoxia under rate-controlled ventilation is associated with a significant alteration in the spontaneous cardiac baroreflex. This important cardiac autonomic imbalance is followed by a significant increase in the cardiac parasympathetic drive even after the disappearance of the hypoxic stimulus.

Adaptation, Physiological↗

Autonomic adaptations to intensive and overload training periods: a laboratory study.

PURPOSE: Looking for practical and reliable markers of fatigue is of particular interest in elite sports. One possible marker might be the autonomic nervous system activity, known to be well affected by physical exercise and that can be easily assessed by heart rate variability. METHODS: We designed a laboratory study to follow six sedentary subjects (32.7 +/- 5.0 yr) going successively through 2 months of intensive physical training and 1 month of overload training on cycloergometer followed by 2 wk of recovery. Maximal power output over 5 min (Plim5'), VO(2) and standard indices of heart rate variability were monitored all along the protocol. RESULTS: During the intensive training period, physical performance increased significantly VO(2peak) : +20.2%, < 0.01; Plim5': +26.4%, < 0.0001) as well as most of the indices of heart rate variability (mean RR, Ptot, HF, rMSSD, pNN50, SDNNIDX, SDNN, all < 0.05) with a significant shift in the autonomic nervous system toward a predominance of its parasympathetic arm (LF/HF, LFnu, HFnu, < 0.01). During the overload training period, there was a stagnation of the parasympathetic indices associated to a progressive increase in sympathetic activity (LF/HF, < 0.05). During the week of recovery, there was a sudden significant rebound of the parasympathetic activity (mean RR, HF, pNN50, rMSSD, all < 0.05). After 7 wk of recovery, all heart rate variability indices tended to return to the prestudy values. CONCLUSION: Autonomic nervous system status depends on cumulated physical fatigue due to increased training loads. Therefore, heart rate variability analysis appears to be an appropriate tool to monitor the effects of physical training loads on performance and fitness, and could eventually be used to prevent overtraining states.

Adaptation, Physiological↗