PubMed Health⌕ Search

Biomedical subjects

Vincent Pizziconi

Publications and source records attributed to Vincent Pizziconi.

2 recordsLinked to original sources

Multiplexed DNA sequencing-by-synthesis.

We report a new DNA sequencing-by-synthesis method in which the sequences of DNA templates, hybridized to a surface-immobilized array of DNA primers, are determined by sensing the number of nucleotides by which the primers in each array spot are extended in sequential DNA polymerase-catalyzed nucleotide incorporation reactions, each with a single fluorescein-labeled deoxyribonucleoside triphosphate (dNTP) species. The fluorescein label is destroyed after each readout by a photostimulated reaction with diphenyliodonium chloride. A DNA polymerase with enhanced ability to incorporate, and to extend beyond, modified nucleotides is used. Self-quenching of adjacent fluorescein labels, which impedes readout of homopolymeric runs, is avoided by diluting the labeled dNTP with unlabeled reagent. Misincorporation effects have been quantified and are small; however, low-level contamination of dNTPs with other nucleotides mimics misincorporation and can produce significant false-positive signals. These impurities are removed by polymerase-catalyzed incorporation into complementary "cleaning duplexes." Here, we demonstrate the accurate sequence readout for a small array of known DNA templates, the ability to quantify homopolymeric runs, and a short sequencing example of sections of the wild-type and mutant BRCA1 gene. For a 20,000-spot array, readout rates in excess of 6000 bases per minute are projected.

Amino Acid Sequence↗

Isolation of plasma from whole blood using planar microfilters for lab-on-a-chip applications.

Researchers are actively developing devices for the microanalysis of complex fluids, such as blood. These devices have the potential to revolutionize biological analysis in a manner parallel to the computer chip by providing very high throughput screening of complex samples and massively parallel bioanalytical capabilities. A necessary step performed in clinical chemistry is the isolation of plasma from whole blood, and effective sample preparation techniques are needed for the development of miniaturized clinical diagnostic devices. This study demonstrates the use of passive, operating entirely on capillary action, transverse-flow microfilter devices for the microfluidic isolation of plasma from whole blood. Using these planar microfilters, blood can be controllably fractionated with minimal cell lysis. A characterization of the device performance reveals that plasma filter flux is dependent upon the wall shear rate of blood in the filtration channel, and this result is consistent with macroscale blood filtration using microporous membranes. Also, an innovative microfluidic layout is demonstrated that extends device operation time via capillary action from seconds to minutes. Efficiency of these microfilters is approximately three times higher than the separation efficiencies predicted for microporous membranes under similar conditions. As such, the application of the microscale blood filtration designs used in this study may have broad implications in the design of lab-on-a-chip devices, as well as the field of separation science.

Cell Separation↗