Are stentless valves superior to modern stented valves? A prospective randomized trial.

BACKGROUND: It is presumed that stentless aortic bioprostheses are hemodynamically superior to stented bioprostheses. A prospective randomized controlled trial was undertaken to compare stentless versus modern stented valves. METHODS AND RESULTS: Patients with severe aortic valve stenosis (n=161) undergoing aortic valve replacement (AVR) were randomized intraoperatively to receive either the C-E Perimount stented bioprosthesis (n=81) or the Prima Plus stentless bioprosthesis (n =80). We assessed left ventricular mass (LVM) regression with transthoracic echocardiography (TTE) and magnetic resonance imaging (MRI). Transvalvular gradients were measured postoperatively by Doppler echocardiography to compare hemodynamic performance. There was no difference between groups with regard to age, symptom status, need for concomitant coronary artery bypass surgery, or baseline LVM. LVM regressed in both groups but with no significant difference between groups at 1 year. In a subset of 50 patients, MRI was also used to assess LVM regression, and again there was no significant difference between groups at 1 year. Hemodynamic performance of the 2 valves was similar with no difference in mean and peak systolic transvalvular gradients 1 year after surgery. In patients with reduced ventricular function (left ventricular ejection fraction [LVEF] <60%), there was a significantly greater improvement in LVEF from baseline to 1 year in stentless valve recipients. CONCLUSIONS: Both stented and stentless bioprostheses are associated with excellent clinical and hemodynamic outcomes 1 year after AVR. Comparable hemodynamics and LVM regression can be achieved using a second-generation stented pericardial bioprosthesis. In patients with ventricular impairment, stentless bioprostheses may allow for greater improvement in left ventricular function postoperatively.

Aged↗

Longitudinal reinforcement for treatment of sternal dehiscence.

Re-fixation of the sternum after sternal dehiscence is still a problem following cardiac surgery. An original technique that allows reinforcement against various causes of dehiscence is described. The technique consists of 3 additional overlapping longitudinal wires set on both sides of the sternum. Over 2 years, this technique was applied in 34 patients, with complete sternal re-fixation in all, and no signs of recurrence on follow-up.

Bone Wires↗

Carpentier-Edwards PERIMOUNT Magna bioprosthesis: a stented valve with stentless performance?

OBJECTIVE: We designed this study to evaluate the early hemodynamic performance of the recently introduced Carpentier-Edwards PERIMOUNT Magna bioprosthesis (Edwards Lifesciences, Irvine, Calif) and compare it with those of the conventional Carpentier-Edwards PERIMOUNT stented bioprosthesis (Edwards Lifesciences) and Edwards Prima Plus porcine stentless bioprosthesis (Edwards Lifesciences). METHODS: Sixty-three patients (>70 years old) were enrolled in this prospective, randomized study. At operation, once the annulus had been measured, the best size suitable was assessed for each of the three valves before random assignment. Transthoracic echocardiography was performed before discharge to evaluate early postoperative hemodynamic performances of the different valves implanted. RESULTS: The best size suitable of Edwards Prima Plus (24.3 +/- 1.7 mm) was significantly superior to those of both the Carpentier-Edwards PERIMOUNT Magna (23.4 +/- 2.1 mm) and Carpentier-Edwards PERIMOUNT (22.4 +/- 1.8 mm). The best size suitable of the Carpentier-Edwards PERIMOUNT Magna, however, was significantly superior to that of the Carpentier-Edwards PERIMOUNT. Furthermore the best size suitable of the Carpentier-Edwards PERIMOUNT Magna was equal to the measured annulus in 55% of patients, as opposed to 25% for the Carpentier-Edwards PERIMOUNT (P < .001). Mean implanted labeled size of the Edwards Prima Plus was significantly higher than those of both the Carpentier-Edwards PERIMOUNT Magna and the Carpentier-Edwards PERIMOUNT (24.6 +/- 1.9 mm, 23.1 +/- 1.9 mm, and 22.5 +/- 1.8 mm, respectively). Early postoperative hemodynamic performance of the Carpentier-Edwards PERIMOUNT Magna, however, was superior to those of both the Edwards Prima Plus and the Carpentier-Edwards PERIMOUNT in both effective orifice area index (1.07 +/- 0.4 cm2/m2, 0.87 +/- 0.3 cm2/m2, and 0.80 +/- 0.2 cm2/m2, respectively) and mean peak gradient (20 +/- 6 mm Hg, 27 +/- 8 mm Hg, and 28 +/- 12 mm Hg, respectively). CONCLUSION: The improved design of the recently introduced third-generation stented bioprosthesis Carpentier-Edwards PERIMOUNT Magna allows implantation of a significantly bigger valve than with the old generation. Furthermore, the improved hemodynamic performance of the Carpentier-Edwards PERIMOUNT Magna compares favorably with both the Carpentier-Edwards PERIMOUNT and the Edwards Prima Plus.

Aged↗

Long and short-term outcomes in patients requiring continuous renal replacement therapy post cardiopulmonary bypass.

OBJECTIVE: The development of acute renal failure following cardiac surgery is a rare but devastating complication with high morbidity and mortality. This study aimed to assess the incidence of acute renal failure necessitating continuous renal replacement therapy (CRRT) in patients who required cardiopulmonary bypass, to determine the factors associated with mortality and to evaluate long-term outcome. METHODS: Patients who underwent cardiac surgery between October 1997 and 2003 and treated with CRRT were included (n=98). Six patients were then excluded (already in established renal failure pre-operatively) and one patient lost to follow-up. A retrospective analysis was carried out. RESULTS: Overall CRRT was used in 2.9% (92/3172). The mean (SD) age of patients was 68 (10) years. Their mean pre-operative creatinine level and duration of cardiopulmonary bypass were 154 (87)micromol/l and 160 (84)min, respectively. Mean duration from surgery to establishment of CRRT was 50 (42)h. Mean creatinine level prior to hospital discharge was 168 (93)micromol/l. Thirty-day mortality was 42%. Significant risk factors for death were complex procedures (odds ratio=9.9), gastro-intestinal complications (OR=7.2), cross-clamp time over 88min (OR=5.9), re-exploration (OR=4.0) and patients age over 75 years (OR=3.3). Actuarial 1 and 5-year survivals (95% CI) were 53 (43, 63) % and 52 (42, 62) %, respectively. Only 2 (2.2%) patients required long term renal support. CONCLUSIONS: Acute renal failure necessitating the use of CRRT is a rare but serious complication post cardiopulmonary bypass. In the long-term, surviving patients are not likely to require further renal support.

Acute Kidney Injury↗