PubMed Health⌕ Search

Biomedical subjects

Vincenzo Pucci

Publications and source records attributed to Vincenzo Pucci.

18 recordsLinked to original sources

Enhanced mass resolution method development, validation and assay application to support preclinical studies of a new drug candidate.

A very highly sensitive and highly selective liquid chromatographic/tandem mass spectrometric (LC/MS/MS) method was developed to evaluate and quantify a new drug candidate in different biological matrices. Following a simple plasma protein precipitation using acetonitrile, the post-treatment samples were analyzed on a C18 column interfaced with a new generation of triple-quadrupole mass spectrometer. The recently introduced triple-quadrupole mass spectrometer, the TSQ Quantum Ultra, with enhanced mass-resolution capability, demonstrated improved sensitivity (0.05 ng/mL), coupled with suitable accuracy and precision, over a broad linear dynamic range (0.05-1000 ng/mL). A comparison of the assay performance data (dynamic range, calibration curve equation, precision and accuracy) of the enhanced resolution method against a unit resolution method under optimized conditions showed the performance improvement of the enhanced mass resolution method for bioanalytical high-throughput applications. The enhanced mass resolution method herein described was successfully applied to the evaluation of the pharmacokinetic profile of a new drug candidate in rat, rabbit and dog plasma samples.

Animals↗

Analysis of antiepileptic drugs in biological fluids by means of electrokinetic chromatography.

An overview of the electrokinetic chromatographic methods for the analysis of antiepileptic drug levels in biological samples is presented. In particular, micellar electrokinetic capillary chromatography is a very suitable method for the determination of these drugs, because it allows a rapid, selective, and accurate analysis. In addition to the electrokinetic chromatographic studies on the determination of antiepileptic drugs, some information regarding sample pretreatment will also be reported: this is a critical step when the analysis of biological fluids is concerned. The electrokinetic chromatographic methods for the determination of recent antiepileptic drugs (e.g., lamotrigine, levetiracetam) and classical anticonvulsants (e.g., carbamazepine, phenytoin, ethosuximide, valproic acid) will be discussed in depth, and their pharmacological profiles will be briefly described as well.

Acetazolamide↗

Analysis of lamotrigine and its metabolites in human plasma and urine by micellar electrokinetic capillary chromatography.

A reliable micellar electrokinetic capillary chromatographic method was developed and validated for the determination of lamotrigine and its metabolites in human plasma and urine. The variation of different parameters, such as pH of the background electrolyte (BGE) and Sodium dodecyl sulfate (SDS) concentration, were evaluated in order to find optimal conditions. Best separation of the analytes was achieved using a BGE composed of 10 mM borate and 50 mM SDS, pH 9.5; melatonin was selected as the internal standard. Isolation of lamotrigine and its metabolites from plasma and urine was accomplished with an original solid-phase extraction procedure using hydrophilic-lypophilic balance cartridges. Good absolute recovery data and satisfactory precision values were obtained. The calibration plots for lamotrigine and its metabolites were linear over the 1-20 microg/mL concentration range. Sensitivity was satisfactory; the limits of detection and quantitation of lamotrigine were 500 ng/mL and 1 microg/mL, respectively. The application of the method to real plasma samples from epileptic patients under therapy with lamotrigine gave good results in terms of accuracy and selectivity, and in agreement with those obtained with an high-performance liquid chromatography (HPLC) method.

Chromatography, High Pressure Liquid↗

High sensitivity determination of valproic acid in mouse plasma using semi-automated sample preparation and liquid chromatography with tandem mass spectrometric detection.

A high-throughput liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) assay using automated sample preparation has been developed for the determination of valproic acid (VPA) in mouse plasma. A liquid-handling system was programmed to prepare calibration standard solutions in plasma, as well as quality controls and clinical samples. Plasma protein precipitation was performed on a 96-well plate, and the collected supernatant was directly injected into a reversed-phase LC/ESI-MS/MS system in the negative ionization mode. The calibration curve for VPA was linear over a dynamic range of 0.15-100 microg/mL. The limit of detection was 75 ng/mL and the lower limit of quantitation was 150 ng/mL. Intra- and inter-day validation assays of the semi-automated plasma analysis showed satisfactory accuracy and precision.

Animals↗

Enantioselective determination of the novel antidepressant mirtazapine and its active demethylated metabolite in human plasma by means of capillary electrophoresis.

Mirtazapine is a recent noradrenergic and specific serotonergic antidepressant drug. A capillary electrophoretic method has been developed for the enantioseparation and analysis of mirtazapine and its main active metabolite, N-desmethylmirtazapine, in human plasma. For method optimisation several experimental parameters were investigated, such as type and concentration of the chiral selector, buffer pH and capillary temperature. Baseline enantioseparation of the analytes was achieved in 2.5 min in a fused silica capillary (50 microm i.d.; 48.5 cm total length; 8.5 cm effective length) using carboxymethyl-beta-cyclodextrin, dissolved in a background electrolyte consisting of 50 mM phosphate buffer at pH 2.5, as the chiral selector. UV detection was set at 205 nm. A careful pre-treatment of plasma samples was developed, using solid-phase extraction with hydrophilic-lipophilic balance cartridges (60 mg, 3 mL), eluting the sample with methanol, then concentrating it 37.5 times before injection. Extraction yield values are very satisfactory, being the average 89% for mirtazapine and 73% for N-desmethylmirtazapine. Application of the method to some human plasma samples has given satisfactory results.

Antidepressive Agents↗

High-performance liquid chromatographic determination of Levetiracetam in human plasma: comparison of different sample clean-up procedures.

An accurate and precise high-performance liquid chromatographic method using diode array detection for the determination of the novel antiepileptic, Levetiracetam, has been developed. Three clean-up procedures for the analysis of Levetiracetam in human plasma were implemented and evaluated, namely solid-phase extraction, deproteinization by addition of organic solvents and formation of insoluble salts. Adenosine was used as the internal standard for all three sample pretreatment procedures. Among the several cartridges used for solid-phase extraction, the hydrophilic-lypophilic balance (Oasis) HLB) phase provides the best extraction yield of Levetiracetam, together with high precision. With the two other clean-up procedures involving plasma deproteinization by addition of methanol or zinc sulphate, lower sensitivity and precision of the assays were obtained. However, they are cheaper and faster when compared with the solid-phase extraction procedure.

Anticonvulsants↗

Reversed-phase capillary electrochromatography for the simultaneous determination of acetylsalicylic acid, paracetamol, and caffeine in analgesic tablets.

The separation and simultaneous determination of caffeine, paracetamol, and acetylsalicylic acid in two analgesic tablet formulations was investigated by capillary electrochromatography (CEC). The effect of mobile phase composition on the separation and peak efficiency of the three analytes was studied and evaluated; in particular, the influence of buffer type, buffer pH, and acetonitrile content of the mobile phase was investigated. The analyses were carried out under optimized separation conditions, using a full-packed silica capillary (75 microm ID; 30.0 cm and 21.5 cm total and effective lengths, respectively) with a 5 microm C8 stationary phase. A mixture of 25 mM ammonium formate at pH 3.0 and acetonitrile (30:70 v/v) was used as the mobile phase. UV detection was at 210 nm. Good linearity was found in the range of 50-200, 20-160, and 4-20 microg/mL for acetylsalicylic acid (r2=0.9988), paracetamol (r2=0.9990) and caffeine (r2=0.9990), respectively. Intermediate precision (RSD interday) as low as 0.1-0.8% was found for retention times, while the RSD values for the peak area ratios (Aanalyte/AIS) were in the range of 1.9-2.9%. The optimized CEC method was applied to the analysis of the studied compounds present in commercial tablets.

Acetaminophen↗

Monolithic columns with a gradient of functionalities prepared via photoinitiated grafting for separations using capillary electrochromatography.

Stationary phases for capillary electrochromatography with a longitudinal gradient of functionalities have been prepared via photoinitiated grafting of polymer chains onto the pore surface of a porous polymer monolith. In order to achieve the desired retention and electroosmotic flow, the hydrophobic poly(butyl methacrylate-co-ethylene dimethacrylate) monolith with optimized porous properties was grafted with a layer of ionizable polymer, poly(2-acrylamido-2-methyl-1-propanesulfonic acid). A moving shutter and a neutral density filter were used to control the dose of UV light received at different locations along the monolith in order to create the longitudinal gradient of functionalities. Formation of the desired gradients was confirmed using electron probe microanalysis of different locations along the column. The preparation technique significantly affects performance in the CEC mode as demonstrated on the separations of a model mixture using columns both with homogeneous distribution of grafts and with a gradient of functionality. Columns grafted with the gradient of functionalities were found superior to those functionalized uniformly. A comparison of the performance of the gradient column with another containing evenly distributed functionalities showed the performance benefits of the "gradient" column.

Electrochemistry↗

Atypical antipsychotics: pharmacokinetics, therapeutic drug monitoring and pharmacological interactions.

The development of new "atypical" antipsychotic agents, which are safer than classical neuroleptics and also active against the negative symptoms and neurocognitive deficits caused by the illness, has produced a significant advancement in the treatment of schizophrenia. The atypical (or "second generation") antipsychotics have several therapeutical properties in common, however they can significantly differ with regard to clinical potency and side effects. The main features regarding pharmacodynamics, pharmacokinetics and pharmacological interactions of the most important atypical antipsychotics, namely clozapine, olanzapine, quetiapine and risperidone, are treated herein. Several analytical methods available for the therapeutic drug monitoring of these drugs are also presented, as well as the novel formulations, which can notably improve the therapy of schizophrenia. Other very recent atypical agents, such as ziprasidone, aripiprazole, iloperidone, sertindole and zotepine will also be briefly described.

Antipsychotic Agents↗

Quality control of commercial tablets containing the novel antipsychotic quetiapine.

Quetiapine (bis [2-(2-[4-(dibenzo[b,f][1,4]thiazepin-11-yl]ethoxy)ethanol]fumarate) is the most recent agent introduced on the drug market for the treatment of psychotic disorders. Two different analytical methods for the quality control of quetiapine in commercial formulations have been developed and compared: a spectrophotometric method and a capillary zone electrophoretic (CZE) method. The spectrophotometric assay was carried out measuring the absorbance at a wavelength of 246 nm. The CZE method used an uncoated fused-silica capillary and a pH 2.5, 50 mM phosphate buffer as the background electrolyte. The detection wavelength was 205 nm, the separation voltage was 15 kV, and a complete electrophoretic run lasts less than 2.5 min. Extraction of quetiapine from the commercial tablets consisted of a simple one-step treatment with a pH 2.5, 50 mM phosphate buffer. Linearity was observed in the 5-25 microg ml(-1) concentration range of quetiapine for the spectrophotometric method, and in the 5-50 microg ml(-1) concentration range for the electrophoretic method. Both methods gave satisfactory results in terms of repeatability and intermediate precision (RSD<1.9%). Also accuracy values were very good for both methods, the recovery being between 98.2 and 100.5%.

Antipsychotic Agents↗

Liquid chromatographic analysis of the cis(Z)- and trans(E)-isomers of clopenthixol in human plasma using a novel solid phase extraction procedure.

A simple and highly sensitive high-performance liquid chromatographic (HPLC) method for the simultaneous determination of cis(Z)-clopenthixol and trans(E)-clopenthixol in human plasma has been developed. The chromatographic analysis was carried out isocratically on a reversed-phase column (C(8) 150 x 4.6 mm I.D., 5 microm) using a mixture of 25 mM phosphate buffer and acetonitrile (65:35 v/v, pH* 3.0) as the mobile phase, and ultraviolet detection at 230 nm. Plasma sample pretreatment was accomplished by means of an original solid-phase extraction (SPE) procedure carried out on cyanopropyl cartridges, with a high extraction yield and good selectivity. Under the optimum conditions, calibration graphs of spiked human plasma samples were obtained over the concentration ranges 1-300 ng ml(-1) for cis(Z)-clopenthixol and 1-200 ng ml(-1) for trans(E)-clopenthixol. The limit of detection (LOD) was 0.3 ng ml(-1) for both cis(Z)- and trans(E)-isomers of clopenthixol. The method was successfully applied to the determination of cis(Z)-clopenthixol and trans(E)-clopenthixol in plasma samples of schizophrenic patients undergoing therapy with zuclopenthixol.

Antipsychotic Agents↗

Determination of progesterone in commercial formulations and in non conventional micellar systems.

Progesterone was determined in commercial pharmaceutical formulations and experimental micellar systems by means of two analytical methods based on liquid chromatography and derivative spectrophotometry. The chromatographic analysis, with ultraviolet detection at 245 nm, was carried out on a C8 column using a mobile phase composed of 2-propanol and a pH 2.5, 30 mM phosphate buffer. Derivative spectrophotometry (DS) used the difference between the values of the first derivative at 227.2 and 253.6 nm. Both methods require only a simple extraction procedure of progesterone from the formulations before analysis. The high-performance liquid chromatography (HPLC) procedure allows for the quantitative determination of progesterone in all pharmaceutical formulations tested (oily and alcoholic injectable solutions, gel preparations and soft capsules) and also of the newly-developed polymeric micellar system. On the contrary, the derivative spectrophotometric method is not suitable for the pharmaceutical formulation containing estradiol and for the new micellar systems. The results obtained with the two methods are in good agreement and always satisfactory in terms of precision and accuracy.

Chemistry, Pharmaceutical↗

Quantitation of oxcarbazepine and its metabolites in human plasma by micellar electrokinetic chromatography.

A reliable micellar electrokinetic chromatographic method for the determination of oxcarbazepine and its two main metabolites, 10-hydroxycarbamazepine and 10,11-trans-dihydroxy-10,11-dihydroxycarbamazepine, in human plasma was developed. The separation and determination of the analytes was achieved using a system consisting of 60 mM SDS in phosphate buffer (30 mM, pH 8.0), to which 20% (v/v) methanol was added. Separation was carried out in an uncoated fused-silica capillary with a separation voltage of 25 kV and currents typically less than 40 microA. Spectrophotometric detection was at 205 nm. Isolation of oxcarbazepine and its metabolites from plasma was accomplished by a solid-phase extraction procedure. The mean extraction yield of the analytes from plasma was higher than 94%. The linear correlation coefficients were better than 0.994 for all analytes. The limit of detection was 0.05 microg/mL, the limit of quantitation 0.15 microg/mL. The repeatability for the spiked blank plasma samples was lower than 1.9% and the intermediate precision lower than 2.1%, both expressed as RSD%. The results obtained analysing real plasma samples from epileptic patients under therapy with Tolep were satisfactory in terms of precision, accuracy and detectability.

Anticonvulsants↗

Determination of valproic acid (2-propylpentanoic acid) in human plasma by capillary electrophoresis with indirect UV detection.

A rapid capillary zone electrophoresis method with indirect UV detection was developed and validated for the determination of valproic acid (VPA) in human plasma. The analyses were carried out under optimized conditions, using a buffer system composed of 15 mM benzoate and 0.5 mM cetyltrimethylammonium bromide at pH 6.0, and 25% v/v methanol; 2-hydroxybutyric acid was selected as the internal standard (IS). The capillary electrophoresis (CE) separation was carried out at a negative potential of 30 kV and the indirect UV detection was operated at 210 +/- 20 nm for all assays. The influence of buffer pH, ionic strength, concentration of electroosmotic flow (EOF) modifier and organic modifier on indirect signal response and migration behavior of the organic acid was investigated. Isolation of VPA from plasma was accomplished by a carefully implemented procedure using methanol as the precipitant agent. Using a high ratio of methanol to plasma for deproteinization (4:1), good absolute recovery of the analyte and satisfactory selectivity was obtained. The calibration line for VPA was linear over the 1-100 microg/mL concentration range. Sensitivity was high; in fact, the limit of detection (LOD) of VPA was 150 ng/mL and 450 ng/mL the limit of quantitation (LOQ). The results obtained analyzing real plasma samples from schizophrenic patients under polytherapy with VPA as well as antipsychotic drugs were satisfactory in terms of precision, accuracy and sensitivity.

Anticonvulsants↗

Enantiomeric separation of citalopram and its metabolites by capillary electrophoresis.

A simple and fast capillary electrophoretic method has been developed for the enantioselective separation of citalopram and its main metabolites, namely N-desmethylcitalopram and N,N-didesmethylcitalopram, using beta-cyclodextrin (beta-CD) sulfate as the chiral selector. For method optimisation several parameters were investigated, such as CD and buffer concentration, buffer pH, and capillary temperature. Baseline enantioseparation of the racemic compounds was achieved in less than 6 min using a fused-silica capillary, filled with a background electrolyte consisting of a 35 mM phosphate buffer at pH 2.5 supplemented with 1% w/v beta-CD sulfate and 0.05% w/v beta-CD at 25 degrees C and applying a voltage of -20 kV. A fast separation method for citalopram was also optimized and applied to the analysis of pharmaceutical formulations. Racemic citalopram was resolved in its enantiomers in less than 1.5 min using short-end injection (8.5 cm, effective length) running the experiments in a background electrolyte composed of a 25 mM citrate buffer at pH 5.5 and 0.04% w/v beta-CD sulfate at a temperature of 10 degrees C.

Biotransformation↗

Determination of melatonin in galenic preparations by LC and voltammetry.

The amount of melatonin in galenic tablets was determined by means of two feasible and accurate analytical methods. The high performance liquid chromatography (HPLC) with ultraviolet detection at 223 nm used a C(18) reversed-phase column; the linear scan voltammetric procedure (LSV) employs a pH 3.0 phosphate buffer as the supporting electrolyte for the oxidation process of melatonin, which has a current intensity maximum at +850 mV. The two methods gave satisfactory results in terms of precision and accuracy. In fact, the data of repeatability and intermediate precision expressed as percentage relative standard deviations (RSD%) were < or =2.8 and the accuracy values, resulting from recovery experiments, were between 99.0 and 101.3%. Both methods are suitable for quality control of melatonin in galenic preparations; the LSV procedure is more rapid, the HPLC method is more sensitive and more precise.

Antioxidants↗

Separation of carbamazepine and five metabolites, and analysis in human plasma by micellar electrokinetic capillary chromatography.

A rapid and feasible method was developed for the analysis of carbamazepine and its five metabolites (10,11-dihydro-10,11-epoxycarbamazepine, 10,11-dihydro-10,11-dihydroxycarbamazepine, 10,11-dihydro-10-hydroxycarbamazepine, 2-hydroxycarbamazepine and 3-hydroxycarbamazepine) in human plasma. Separation of the analytes is based on micellar electrokinetic chromatography, in untreated fused-silica capillary (48.5/40.0 cm length, 50 microm I.D.) with phosphate buffer (30 mM, pH 8.00) as background electrolyte, containing 50 mM sodium dodecylsulfate, and methanol (15%, v/v) as organic modifier. Clean up of human plasma samples was carried out by means of a solid-phase extraction procedure, which gave a high extraction yield for all six carbamazepines (>88%). The overall precision of the method gives a mean RSD of about 1.8%. The limit of quantitation for all analytes is < or = 0.30 microg ml(-1), the limit of detection < or = 0.12 microg ml(-1).

Anticonvulsants↗

Long-term follow-up after transscleral diode laser photocoagulation in refractory glaucoma.

BACKGROUND AND OBJECTIVE: Patients affected by glaucoma refractory to medical or surgical treatment are difficult to treat. The aim of this study was to evaluate the long-term effect of contact transscleral diode laser cyclophotocoagulation (DLPC) on intraocular pressure (IOP) and on visual acuity of these patients. PATIENTS AND METHODS: One hundred and twenty eyes of 107 patients suffering from refractory glaucoma and treated with DLPC were followed at the Eye Clinic of Verona University for an average of 26 +/- 8 months. Mean age was 57 +/- 26 years. IOP, visual acuity, and ocular complications were analyzed. RESULTS: A total of 207 treatments were given. More than one treatment was given in 55 eyes (45.8%). Mean pretreatment IOP was 30.4 +/- 3.1 mm Hg. At the last follow-up, mean IOP was 20.3 +/- 1.8 mm Hg. Mean total medications were reduced from 4.5 +/- 0.5 to 2.3 +/- 0.3. No serious complications occurred in the 207 treatments. Visual acuity remained stable in 66 eyes (55%), improved in 25 eyes (20.8%), and decreased in 29 eyes (24.2%). CONCLUSIONS: DLPC was effective in lowering IOP in eyes with refractory glaucoma. It also served to reduce the number of antiglaucoma medications, thus improving both the quality of life of the patients and their compliance to therapy. This procedure is relatively safe, very fast and easy to learn. However, careful attention is required to determine the exact position of the ciliary body in malformative glaucoma. Multiple treatments may be required to control IOP.

Administration, Topical↗