PubMed Health⌕ Search

Biomedical subjects

Vincenzo Tursi

Publications and source records attributed to Vincenzo Tursi.

4 recordsLinked to original sources

Stented bioprosthetic valve hemodynamics: is the supra-annular implant better than the intra-annular?

BACKGROUND AND AIM OF THE STUDY: The use of stented bioprostheses for aortic valve replacement (AVR) in elderly patients with a small aortic annulus may result in unsatisfactory hemodynamic performance of the prosthesis. To overcome this limitation, new bioprostheses have been designed for complete supra-annular implantation, but the actual hemodynamic advantage of the supra-annular implant over the intra-annular has not been fully investigated. Accordingly, the hemodynamic performance of the same stented bioprosthesis (except for sewing ring design) implanted in the supra-annular and conventional intra-annular seating was compared. METHODS: Twenty-two patients received an intra-annular implant, and 38 a supra-annular implant. Age (74 +/- 5 versus 76 +/- 5 years, p = 0.54), gender (55% versus 50% males, p = 0.79) and body surface area (1.74 +/- 0.2 versus 1.81 +/- 0.2 m2, p = 0.13) were similar in both subgroups, who underwent echocardiography at 8 +/- 2 and 6 +/- 2 months after surgery, respectively (p = 0.09). RESULTS: The two patient subgroups had similar preoperative left ventricular outflow tract diameters (2.06 +/- 0.2 and 2.1 +/- 0.2 cm; p = 0.62), average size of implanted prosthesis (21.0 and 21.3 mm; p = 0.44) and mean transprosthetic flow rate (246 +/- 70 and 218 +/- 58 ml/s; p = 0.12). Mean (8 +/- 3 and 19 +/- 8 mmHg, p < 0.0001), and peak (17 +/- 6 and 40 +/- 13 mmHg; p < 0.0001) transprosthetic gradients were lower, and mean effective orifice area (EOA) (1.78 +/- 0.4 and 1.45 +/- 0.5 cm2, p = 0.006) was higher in patients with supra-annular implants than in those with intraannular. The incidence of patient-prosthesis mismatch (EOA index < 0.85 cm2/m2) decreased from 50% to 34% (p < 0.0001), with no case of severe mismatch using the supra-annular implant. During follow up, a left ventricular mass reduction occurred in patients with supra-annular implants (from 225 +/- 110 to 173 +/- 59 g/m2; p < 0.03), but not in patients with intra-annular implants (173 +/- 62 and 186 +/- 64 g/m2; p = 0.87) CONCLUSION: The study results showed that, compared to intra-annular implantation, supra-annular implantation of bioprosthetic stented valves in the aortic position was associated with a significantly better hemodynamic performance of the prosthesis and significant regression of left ventricular hypertrophy.

Aged↗

One-year clinical experience with the Acorn CorCap cardiac support device: results of a limited market release safety study in Italy and Sweden.

BACKGROUND: The Acorn CorCap cardiac support device (CSD) is a mesh-like device intended to provide end-diastolic support and reduce ventricular wall stress. Animal studies with the CorCap CSD have demonstrated beneficial reverse remodeling, and preliminary safety studies in patients with heart failure have shown that the device is safe and associated with improved left ventricular (LV) structure and function. The objective of the current study was to further evaluate the safety and efficacy of the CorCap CSD in patients with advanced heart failure. METHODS: Twenty-four patients with dilated cardiomyopathy, severe LV dysfunction, and advanced heart failure (NYHA class II-IV) were enrolled at four centers in Italy and Sweden. All patients underwent CorCap CSD implantation either alone (n = 3) or in combination with mitral valve repair/replacement (n = 13), coronary artery bypass surgery (n = 6), combined mitral valve repair/coronary artery bypass surgery (n = 1) or aneurysmectomy (n = 1). RESULTS: The LV end-diastolic diameter decreased from 69.3 +/- 7.2 to 60.1 +/- 9.0 mm at 3 months, 60.9 +/- 9.6 mm at 6 months, and 58.9 +/- 8.0 mm at 12 months (all p < 0.05). A trend toward an improved LV ejection fraction (28.8 +/- 10.5% at baseline and 32.4 +/- 12.7, 33.1 +/- 10.8, and 33.8 +/- 13.9% at 3, 6 and 12 months respectively) was also noted. The NYHA functional class, 6-min walking distance, and quality of life as measured using Uniscale were all improved. There were no differences in response among the patients submitted to the different types of concomitant surgery. CONCLUSIONS: In agreement with earlier safety studies, even the present investigation demonstrated improvements in cardiac structure and function as well as in patient functional status after Cor Cap CSD implantation. Randomized controlled trials are in progress.

Adult↗

Long-term decrease in subjective perceived efficacy of immunosuppressive treatment after heart transplantation.

BACKGROUND: Mild, long-term non-compliance with immunosuppressive treatment after organ transplantation is common, and can result in early mortality. One possible source of non-compliance is the belief that the treatment is ineffective or unnecessary. This study investigates patients perception of the efficacy of their immunosuppressive treatment in a sample of heart transplant patients. METHODS: A questionnaire was given to 67 heart transplant recipients. The first part of the questionnaire addressed health-related behavior and attitude toward the immunosuppressive medication, using self-report questions. In the second part of the questionnaire, participants evaluated the perceived risk of rejection associated with non-compliant behaviors described in 8 scenarios. RESULTS: The data from the self-report questions showed a mild level of behavioral non-compliance, increasing over time, and a mild level of medication non-compliance. One third of the medication non-compliant patients chose the inefficacy or non-necessity of the treatment as a main cause of non-compliance. The second part of the questionnaire showed that subjective perceived efficacy of the immunosuppressive treatment decreased over time. CONCLUSIONS: Medication non-compliance is fostered by many factors. One of these is the belief that the treatment is ineffective or unnecessary. This belief increases over time, and could be the result of a non-clinical selective-attention bias.

Female↗

Frontal cerebral blood flow is impaired in patients with heart transplantation.

Patients with cardiovascular disease have cognitive function disturbances that are still evident after heart transplantation (HT). The aim of this study was to evaluate cerebral function in transplant patients and to assess whether cyclosporine therapy was responsible for cerebral abnormalities 1 year after transplantation. Six HT patients, eight liver transplant (LT) patients, and ten age-matched healthy controls underwent regional cerebral blood flow (rCBF) assessment by the (99m)Tc-hexamethyl-propylene-amineoxime ((99m)Tc-HM-PAO) single-photon emission computed tomography (SPECT) technique. The rCBF was correlated with cyclosporine blood levels. rCBF in HT and LT patients was similar to that of controls in all regions assayed, except for the frontal inferior region of HT patients, where it was significantly lower than in controls. No correlations between rCBF and cyclosporine blood levels were found in either HT or LT patients. In conclusion, the cerebral abnormalities seen in patients after HT but not after LT may be due to long-standing cerebral hypoperfusion resulting from severe heart disease, whereas cyclosporine does not account for such functional alterations.

Adult↗