PubMed Health⌕ Search

Biomedical subjects

Vivian S Lee

Publications and source records attributed to Vivian S Lee.

At least 19 recordsLinked to original sources

Renal function measurements from MR renography and a simplified multicompartmental model.

The purpose of this study was to determine the accuracy and sources of error in estimating single-kidney glomerular filtration rate (GFR) derived from low-dose gadolinium-enhanced T1-weighted MR renography. To analyze imaging data, MR signal intensity curves were converted to concentration vs. time curves, and a three-compartment, six-parameter model of the vascular-nephron system was used to analyze measured aortic, cortical, and medullary enhancement curves. Reliability of the parameter estimates was evaluated by sensitivity analysis and by Monte Carlo analyses of model solutions to which random noise had been added. The dominant sensitivity of the medullary enhancement curve to GFR 1-4 min after tracer injection was supported by a low coefficient of variation in model-fit GFR values (4%) when measured data were subjected to 5% noise. These analyses also showed the minimal effects of bolus dispersion in the aorta on parameter reliability. Single-kidney GFR from MR renography analyzed by the three-compartment model (4.0-71.4 ml/min) agreed well with reference measurements from (99m)Tc-DTPA clearance and scintigraphy (r = 0.84, P < 0.001). Bland-Altman analysis showed an average difference of 11.9 ml/min (95% confidence interval = 5.8-17.9 ml/min) between model and reference values. We conclude that a nephron-based multicompartmental model can be used to derive clinically useful estimates of single-kidney GFR from low-dose MR renography.

Computer Simulation↗

Improved visualization of non-transmural scar using slice-selective inversion-recovery delayed contrast-enhanced MRI: a preliminary report.

Delayed contrast-enhanced MRI (ce-MRI) pulse sequence is a promising modality for the assessment of myocardial viability. However, conventional ce-MRI using a non-selective inversion recovery (IR) pulse can often yield poor edge definition or contrast-to-noise ratio (CNR) between the non-transmural scar and blood (i.e. the blood and scar appear isointense). Subtraction and multicontrast ce-MRI methods can be used to improve the CNR between the non-transmural scar and blood, but they require two image acquisitions. The authors have developed a single-acquisition ce-MRI pulse sequence that utilizes a slice-selective IR pulse to generate bright-blood contrast using inflow effects for an improved edge definition between the non-transmural scar and blood. Six patients with myocardial infarction were imaged at 1.5 T using both non-selective and slice-selective IR ce-MRI acquisitions with identical imaging parameters. The CNR between the non-transmural scar and normal myocardium was not different between the two acquisitions. The CNR between the blood and non-transmural scar (16.9 +/- 12.3 versus 3.2 +/- 7.9; p < 0.001) was significantly higher for the slice-selective IR acquisition than for the non-selective IR acquisition. This study demonstrates the feasibility of using a slice-selective IR pulse to improve the visualization of a non-transmural scar in ce-MRI, without increasing the acquisition time.

Adult↗

Hepatocellular carcinoma in the cirrhotic liver: gadolinium-enhanced 3D T1-weighted MR imaging as a stand-alone sequence for diagnosis.

PURPOSE: To retrospectively assess the usefulness of contrast material-enhanced T1-weighted magnetic resonance (MR) imaging alone and with T2-weighted MR imaging in the diagnosis of hepatocellular carcinoma (HCC). MATERIALS AND METHODS: A waiver of informed consent and institutional review board approval for this retrospective study were granted. The study was HIPAA compliant. Twenty-eight men (mean age, 49 years; range, 23-70 years) and 10 women (mean age, 53 years; range, 42-72 years) with cirrhosis underwent T2-weighted and contrast-enhanced T1-weighted MR imaging at 1.5 T within 90 days of liver transplantation. Three readers reviewed the T1-weighted images alone and then the T2-weighted and T1-weighted images together. Lesion detection, characterization, and reader confidence levels were recorded. RESULTS: At liver explantation, 57 lesions were present in 18 patients: 19 HCCs, 33 dysplastic nodules, and five cysts. Contrast-enhanced T1-weighted imaging depicted 13 of 19 HCCs with an overall sensitivity of 68.4% (13 of 19) and specificity of 65.7% (23 of 35). The sensitivity and specificity for detection of dysplastic nodules (sensitivity, 9%; specificity, 68.4%) and HCCs (sensitivity, 68.4%; specificity, 65.7%) were nearly identical for T1-weighted images read alone or read with T2-weighted images. The only difference was the specificity for T1-weighted images read alone (65.7%) and read with T2-weighted images (62.9%). The addition of T2-weighted images altered the diagnosis in one of 90 (1.1%) cases and provided an increase in diagnostic confidence in four of 258 (1.6%) cases for independent readers and three of 90 (3.3%) cases at consensus reading. CONCLUSION: Contrast-enhanced T1-weighted imaging can be used as a stand-alone sequence for the diagnosis of HCC in patients with cirrhosis prior to liver transplantation.

Adult↗

Opposed-phase MRI for fat quantification in fat-water phantoms with 1H MR spectroscopy to resolve ambiguity of fat or water dominance.

OBJECTIVE: The purpose of the study was to quantify the fat fraction in nine fat-water phantoms containing 0-80% fat using opposed-phase imaging with the qualitative guidance of 1H MR spectroscopy (MRS), which was used by observer 1 to visually assess the sizes of the water and fat peaks to apply two alternative mathematic formulas for the calculation of the fat fraction. In addition, the fat fraction was also quantified directly with 1H MRS as an independent method by two observers (observers 2 and 3). CONCLUSION: The fat fraction calculated with opposed-phase imaging (FF(OPI)) and that calculated with 1H MRS (FF(MRS)) correlated well with the known fat fractions of the phantoms (FF(P)): r = 0.99 for FF(OPI); p < 0.0001 and r = 0.96-0.98 for FF(MRS); p < 0.001, for observers 2 and 3, respectively. Opposed-phase imaging should be combined with 1H MRS to ensure accurate quantification of the fat fraction.

Animals↗

Isotropic 3D T2-weighted MR cholangiopancreatography with parallel imaging: feasibility study.

OBJECTIVE: The aim of this study was to compare the quality of images obtained with fast 3D T2-weighted turbo spin-echo (TSE) MR cholangiopancreatography (MRCP) sequences and 1-mm isotropic voxels with the quality of conventional 2D MRCP images. SUBJECTS AND METHODS: Thirty consecutively registered patients (14 women, 16 men; average age, 60.2 years; age range, 32-87 years) underwent imaging at 1.5 T with a 6-element body array coil. All imaging was performed with three MRCP techniques: free-breathing 3D T2-weighted TSE (TR/TE, 1,300/680; flip angle, 180 degrees; field of view, 250-300 mm; matrix size, 256 x 256; slice thickness, 1 mm; parallel acquisition technique factor, 2); breath-hold 3D T2-weighted TSE (same parameters as the free-breathing 3D technique); breath-hold coronal and oblique coronal thick-slab 2D TSE without parallel acquisition technique (2,800/1,100; flip angle, 150-180 degrees). Quantitative measures of image signal and contrast were evaluated by analysis of variance and paired Student's t tests. A 5-point scale (1, nondiagnostic, to 5, high diagnostic confidence) was used to compare the 3D and 2D data sets for image quality and definition of biliary and pancreatic ductal anatomic features. Friedman's nonparametric and Wilcoxon's rank sum tests were performed for statistical analysis of the qualitative assessments. RESULTS: Quantitative results showed free-breathing and breath-hold 3D TSE images had significantly higher relative signal intensity and contrast than 2D TSE images (p < 0.0001). The qualitative findings showed that both free-breathing and breath-hold 3D TSE techniques gave better delineation of biliary anatomy (p < 0.0001) than the 2D technique. The overall quality of 3D images was better than that of 2D images, and 3D imaging was better at depicting pancreatic ducts, although the difference did not reach statistical significance. CONCLUSION: Three-dimensional volumetric MRCP images are of superior quality and give better delineation of pancreaticobiliary anatomy than conventional 2D images and have the added advantage of multiplanar and postprocessing capabilities.

Adult↗

Time-resolved 3D MR angiography with parallel imaging for evaluation of hemodialysis fistulas and grafts: initial experience.

OBJECTIVE: We optimized a time-resolved 3D contrast-enhanced MR angiography sequence with integrated parallel imaging technique that can provide a large field of view with high temporal and spatial resolution, by which the hemodialysis access and the entire course of the inflow and outflow vessels can be imaged at a single anatomic station. Our objective was to evaluate the feasibility and usefulness of this method in the evaluation of patients referred for possible abnormalities in hemodialysis access. CONCLUSION: Time-resolved contrast-enhanced 3D MR angiography with parallel imaging has the potential to provide a rapid and comprehensive evaluation for the surveillance and diagnosis of hemodialysis access malfunctions. This technique may function as an important complement to conventional digital subtraction angiography and may be able to help guide medical management. The MR angiography protocol we present is a noninvasive, versatile, and time-efficient technique, without the need of direct graft puncture or flow interruption, and can be performed using a single injection of contrast material at a single station.

Aged↗

Automatic 4-D registration in dynamic MR renography based on over-complete dyadic wavelet and Fourier transforms.

Dynamic contrast-enhanced 4-D MR renography has the potential for broad clinical applications, but suffers from respiratory motion that limits analysis and interpretation. Since each examination yields at least over 10-20 serial 3-D images of the abdomen, manual registration is prohibitively labor-intensive. Besides in-plane motion and translation, out-of-plane motion and rotation are observed in the image series. In this paper, a novel robust and automated technique for removing out-of-plane translation and rotation with sub-voxel accuracy in 4-D dynamic MR images is presented. The method was evaluated on simulated motion data derived directly from a clinical patient's data. The method was also tested on 24 clinical patient kidney data sets. Registration results were compared with a mutual information method, in which differences between manually co-registered time-intensity curves and tested time-intensity curves were compared. Evaluation results showed that our method agreed well with these ground truth data.

Algorithms↗

MR imaging of the gallbladder and biliary system.

MR imaging is an established technique for the diagnosis of a spectrum of biliary and gallbladder pathologies and continues to improve with the advent of technologic advances, including new contrast agents and new sequences that are capable of improving upon the contrast resolution and signal-to-noise that are afforded by conventional MR imaging. These improvements already have shown promise for the increasing role of MRC as the initial modality in assessing living liver donors and evaluating post-operative hepato-biliary complications. Improved spatial resolution and the added functional or physiologic information afforded by MR imaging promise ever expanding clinical applicability and usefulness.

Bile Duct Diseases↗

Perfusion imaging of the liver: current challenges and future goals.

Improved therapeutic options for hepatocellular carcinoma and metastatic disease place greater demands on diagnostic and surveillance tests for liver disease. Existing diagnostic imaging techniques provide limited evaluation of tissue characteristics beyond morphology; perfusion imaging of the liver has potential to improve this shortcoming. The ability to resolve hepatic arterial and portal venous components of blood flow on a global and regional basis constitutes the primary goal of liver perfusion imaging. Earlier detection of primary and metastatic hepatic malignancies and cirrhosis may be possible on the basis of relative increases in hepatic arterial blood flow associated with these diseases. To date, liver flow scintigraphy and flow quantification at Doppler ultrasonography have focused on characterization of global abnormalities. Computed tomography (CT) and magnetic resonance (MR) imaging can provide regional and global parameters, a critical goal for tumor surveillance. Several challenges remain: reduced radiation doses associated with CT perfusion imaging, improved spatial and temporal resolution at MR imaging, accurate quantification of tissue contrast material at MR imaging, and validation of parameters obtained from fitting enhancement curves to biokinetic models, applicable to all perfusion methods. Continued progress in this new field of liver imaging may have profound implications for large patient groups at risk for liver disease.

Carcinoma, Hepatocellular↗

Importance of small (< or = 20-mm) enhancing lesions seen only during the hepatic arterial phase at MR imaging of the cirrhotic liver: evaluation and comparison with whole explanted liver.

PURPOSE: To retrospectively assess the importance and imaging appearance of small (< or = 20 mm in diameter) hepatic arterial phase-enhancing (HAPE) lesions that are occult during portal and/or equilibrium phases and at unenhanced T1- and T2-weighted magnetic resonance (MR) imaging and to determine the gross pathologic diagnosis with whole-liver explant comparison. MATERIALS AND METHODS: This retrospective study was approved by the institutional review board and compliant with HIPPA. Forty-six patients with cirrhosis who underwent MR imaging and transplantation within 90 days were evaluated with breath-hold T2-weighted and volumetric three-dimensional gadolinium-enhanced gradient-echo MR imaging in the hepatic arterial, portal venous, and equilibrium phases at 1.5 T. Three readers, who were blinded to the pathologic results, retrospectively reviewed the MR images in consensus for small HAPE nodules that were occult at T2-weighted and portal and/or equilibrium phase MR imaging. Only patients with nodules that enhanced during the arterial phase were included in the final study group, which included 16 patients (12 men and four women) aged 18-66 years (median age, 51.5 years). Explanted livers were serially sliced into 5-8-mm-thick sections to evaluate dysplastic nodules and hepatocellular carcinomas (HCCs). The Fisher exact test was performed to determine whether there was a relationship between HCC and the presence of a neoplastic HAPE-only lesion. The Mann-Whitney test was used to determine if patients with at least one neoplastic HAPE-only lesion had a larger number of non-HAPE-only lesions. RESULTS: The 16 patients had 45 HAPE-only lesions; three (7%) of which were neoplastic, including one overt HCC, one HCC arising in a dysplastic nodule, and one dysplastic nodule. None of the remaining 42 HAPE-only lesions (93%) had correlative pathologic findings. All three neoplastic lesions seen only during the arterial phase were found in eight patients with concomitant HCC, who also had an additional 13 pathologically proved nonneoplastic HAPE-only lesions. In eight patients without HCC, none of the HAPE-only lesions were neoplastic. A concomitant non-HAPE-only neoplastic lesion was not a significant (P = .2) predictor for the presence of at least one neoplastic HAPE-only lesion. There was a preliminary but insignificant (P = .13) indication that the number of non-HAPE-only lesions tends to be higher in patients with neoplastic HAPE-only lesions. CONCLUSION: The majority (93%) of HAPE-only lesions that are occult at T2-weighted and portal and/or equilibrium phase MR imaging are nonneoplastic, even in patients with pathologically proved HCC.

Adolescent↗

Defining intrahepatic biliary anatomy in living liver transplant donor candidates at mangafodipir trisodium-enhanced MR cholangiography versus conventional T2-weighted MR cholangiography.

PURPOSE: To compare three-dimensional (3D) mangafodipir trisodium-enhanced T1-weighted magnetic resonance (MR) cholangiography with conventional T2-weighted MR cholangiography for depiction and definition of intrahepatic biliary anatomy in liver transplant donor candidates. MATERIALS AND METHODS: One hundred eight healthy liver transplant donor candidates were examined with two MR cholangiographic methods. All candidates gave written informed consent, and the study was approved by the institutional review board. First, breath-hold transverse and coronal half-Fourier single-shot turbo spin-echo and breath-hold oblique coronal heavily T2-weighted turbo spin-echo sequences were performed. Second, mangafodipir trisodium-enhanced breath-hold fat-suppressed 3D gradient-echo sequences were performed through the ducts (oblique coronal plane) and through the entire liver (transverse plane). Interpretation of biliary anatomy findings, particularly variants affecting right liver lobe biliary drainage, and degree of interpretation confidence at both 3D mangafodipir trisodium-enhanced MR cholangiography and T2-weighted MR cholangiography were recorded and compared by using the Wilcoxon signed rank test. Then, consensus interpretations of both MR image sets together were performed. Intraoperative cholangiography was the reference-standard examination for 51 subjects who underwent right lobe hepatectomy. The McNemar test was used to compare the accuracies of the individual MR techniques with that of the consensus interpretation of both image sets together and to compare each technique with intraoperative cholangiography. RESULTS: Biliary anatomy was visualized with mangafodipir trisodium enhancement in all patients. Mangafodipir trisodium-enhanced image findings agreed with findings seen at combined interpretations significantly more often than did T2-weighted image findings (in 107 [99%] vs 88 [82%] of 108 donor candidates, P < .001). Confidence was significantly higher with the mangafodipir trisodium-enhanced images than with the T2-weighted images (mean confidence score, 4.5 vs 3.4; P < .001). In the 51 candidates who underwent intraoperative cholangiography, mangafodipir trisodium-enhanced imaging correctly depicted the biliary anatomy more often than did T2-weighted imaging (in 47 [92%] vs 43 [84%] donor candidates, P = .14), whereas the two MR imaging techniques combined correctly depicted the anatomy in 48 (94%) candidates. CONCLUSION: Mangafodipir trisodium-enhanced 3D MR cholangiography depicts intrahepatic biliary anatomy, especially right duct variants, more accurately than does conventional T2-weighted MR cholangiography.

Adolescent↗

Myocardial infarction: optimization of inversion times at delayed contrast-enhanced MR imaging.

Seventeen patients underwent magnetic resonance (MR) imaging for myocardial viability with a protocol approved by the institutional review board and gave written informed consent. Breath-hold cine inversion-recovery segmented k-space true fast imaging with steady-state precession sequence, referred to as inversion time (TI) mapping, was performed to determine optimal TI for myocardial infarction inversion-recovery imaging. From TI mapping, optimal TI was 180-315 msec 10-15 minutes after administration of 0.15 mmol/kg of gadolinium-based contrast material. At that optimal TI, relative signal intensity of infarcted myocardium compared with uninfarcted myocardium was maximal (mean +/- standard deviation, 297.8% +/- 86.5), whereas signal-to-noise ratio of uninfarcted myocardium was minimal (4.5 +/- 1.2). When applied to conventional myocardial infarction inversion-recovery imaging, optimal TI resulted in nulling of signal intensity of uninfarcted myocardium in all patients and in excellent conspicuity of infarcted myocardium in all nine patients with visible infarction.

Adult↗

Renal masses: quantitative analysis of enhancement with signal intensity measurements versus qualitative analysis of enhancement with image subtraction for diagnosing malignancy at MR imaging.

PURPOSE: To retrospectively compare quantitative and qualitative methods of assessing magnetic resonance (MR) imaging contrast enhancement as the basis for diagnosing renal malignancy. MATERIALS AND METHODS: MR imaging was performed by using a gadolinium-enhanced breath-hold fat-suppressed three-dimensional T1-weighted gradient-echo sequence in 71 patients (48 men and 23 women; mean age, 62 years; age range, 26-87 years) with 93 renal lesions for which pathologic correlation was available. For quantitative measurements of enhancement, the relative increase in signal intensity values was measured by one investigator with manually defined regions of interest, and the threshold of an increase of 15% or greater was used to distinguish malignant from benign masses. For qualitative assessment, two investigators independently reviewed the subtracted images of all lesions and subjectively determined whether enhancement was present or absent. The sensitivity, specificity, and positive and negative predictive values for each method were calculated and compared. Mean (+/- standard deviation) and median values of relative enhancement were also calculated for benign and malignant lesions. RESULTS: At pathologic analysis, 74 (80%) of the 93 lesions were malignant, and 19 (20%)-including seven oncocytomas-were benign. For diagnosing malignancy based on enhancement alone, sensitivity and specificity, respectively, were 95% (70 of 74 lesions) and 53% (10 of 19 lesions) at quantitative analysis and 99% (73 of 74 lesions) and 58% (11 of 19 lesions) at qualitative analysis. All seven oncocytomas were considered to be malignant with both methods. When the oncocytomas were excluded, specificities increased to 83% (10 of 12 lesions) and 92% (11 of 12 lesions) for the quantitative and qualitative evaluations, respectively. Three of the four malignant lesions incorrectly characterized as benign at quantitative assessment were hyperintense on unenhanced MR images; all were diagnosed correctly at qualitative evaluation. CONCLUSION: Image subtraction enables accurate assessment of renal tumor enhancement, particularly in the setting of masses that are hyperintense on unenhanced MR images.

Adult↗

Liver transplant donor candidates: associations between vascular and biliary anatomic variants.

Our objective was to investigate the coexistence of vascular and biliary anatomic variants, the latter of which are known to increase the risk of biliary complications in living liver donor transplantation. A total of 108 consecutive liver donor candidates were examined by magnetic resonance (MR) imaging that included 2 MR cholangiography methods, T2-weighted MR cholangiography and mangofodipir-enhanced T1-weighted three-dimensional (3D) MR cholangiography, as well as gadolinium-enhanced MR angiography and venography of the liver. Images were interpreted by at least 2 investigators in consensus for definition of hepatic arterial, portal venous, and biliary anatomy. A subset of 51 subjects underwent laparotomy for right hepatectomy. Of the 108 subjects examined, 50 (46%) demonstrated normal hepatic artery, portal vein, and biliary anatomy. Variants of the hepatic artery were found in 27 of 108 (25%) subjects, of the portal vein in 12 of 108 (11%) subjects, and of the bile ducts in 30 of 108 (28%) subjects. Of the 27 subjects with hepatic arterial variants, 8 (30%) also had variant biliary anatomy. The association between hepatic arterial variants and biliary variants was not statistically significant (P >.5). However, of the 12 subjects with portal vein variants, 7 (58%) had biliary variants, and in 6 of 7 cases, the right posterior hepatic duct was anomalous. By chi-square analysis, the association between portal venous and biliary variants was significant (P =.012). In conclusion, over half of subjects with portal vein variants were found to have anomalous biliary anatomy, which always involved the hepatic ducts of the right lobe. The association between portal venous and biliary variants is statistically significant, while there is no significant association between hepatic arterial and biliary variants.

Biliary Tract↗

Functional renal MR imaging.

MR imaging is the only noninvasive test that may provide a complete picture of renal status with minimal risk to the patient, simultaneously improving diagnosis and lowering costs. This article reviews several MR renography techniques, including approaches for quantifying renal perfusion and glomerular filtration rate. Also discussed are clinical applications for the diagnosis and follow-up of renovascular disease, hydronephrosis,and renal transplant dysfunction. The article concludes with an overview of technical problems and challenges facing MR renography.

Contrast Media↗

Renal magnetic resonance imaging.

PURPOSE OF REVIEW: Current magnetic resonance imaging systems allow the visualization of normal and diseased kidney, with exquisite resolution of renal structures. Dynamic contrast magnetic resonance imaging has the potential, unique among all noninvasive modalities, to differentiate diseases that affect different portions of the vascular-nephron system. This article reviews the most important recently published studies in selected topics chosen because of their clinical relevance or potential for technical developments. RECENT FINDINGS: Magnetic resonance imaging is used increasingly to evaluate renal masses, the prenatal genitourinary system, urinary obstruction and infection, renal vasculature, and the kidneys of transplant donors and recipients. Dynamic contrast magnetic resonance renography based on gadolinium chelated to diethylenetriamine pentaacetic acid, a safe (non-nephrotoxic) paramagnetic agent, emerges as the functional renal imaging modality of choice. Both perfusion and filtration rates can be assessed in individual kidney. SUMMARY: Magnetic resonance imaging has the potential to provide a complete anatomic, physiologic, kidney-specific evaluation. With future advances in automated image analysis methods we can expect functional renal magnetic resonance imaging to play an influential role in management of renal disease.

Acute Disease↗