PubMed Health⌕ Search

Biomedical subjects

Vladimir A Hodgev

Publications and source records attributed to Vladimir A Hodgev.

3 recordsLinked to original sources

Long-term changes in dyspnea, lung function, and exercise capacity in COPD patients.

OBJECTIVE: To examine longitudinal changes in dyspnea, lung function, and exercise capacity in COPD patients and to compare baseline data of frequent and infrequent exacerbators at trial entry. METHODS: Nineteen stable COPD patients without significant co-morbidity (age, 58.4 +/- 8.4 years; FEV1% = 33 +/- 12%; mean +/- SD) participated in the study. After a mean period of 36 months (range = 24 - 49) the patients were retested using an identical protocol. RESULTS: Repeated measures analysis showed that there was significant deterioration of FEV1 L (from 1.028 +/- 0.349 to 0.928 +/- 0.307; p = 0.007), PImax cm H2O (from 61.9 +/- 24.2 to 42.0 +/- 22.1; p = 0.007), PaO2 mm Hg (from 69.0 +/- 8.6 to 60.1 +/- 6.8; p = 0.003), PaCO2 mm Hg (from 43.1 +/- 4.9 to 47.3 +/- 4.5; p = 0.001), ATS (from 2.4 +/- 1.0 to 2.8 +/- 0.8; p = 0.031), and 6MWD m (from 389 +/- 130 to 341 +/- 135; p = 0.014). There were also changes in IC, T(L,CO)/V(A), PAP and Borg, but they were not statistically significant. Differentiation of patients by frequency of exacerbations per year of observation (> 2 < or =) discriminated them with respect to functional parameters (FEV1, FVC, IC), dyspneic indices (ATS, VAS and Borg) and exercise capacity (6MWD) at the time of enrollment. CONCLUSIONS: 1) Lung function parameters, blood-gas and dyspneic indices, and exercise capacity decline over a mean period of 36 month in patients with COPD; 2) Patients with frequent exacerbations experience more dyspnea and have lower levels of lung function and exercise capacity at trial entry.

Disease Progression↗

Tidal breathing analysis in school-age children. Comparison with the parameters of forced expiration.

UNLABELLED: Tidal breathing analysis is a method which has the potential to be used for distinguishing and follow-up of airflow obstruction (AFO) in infants, children and critically ill patients. The aim of the present study was to analyse the tidal breathing parameters (TBP) in healthy and in asthmatic school-age children and to compare them with the parameters of forced expiration. SUBJECTS: Two hundred and twenty five healthy children and 100 asthmatics (7 to 14 years- old) took part in the present study. RESULTS: The results show that TBPs exhibit great inter- and intraindividual variability, even if the mean value of 10 consecutive breathing cycles is used. Parameters that reflect the tidal expiratory flow pattern--V(PTEF)/V(E) and T(PTEF)/T(E) demonstrate high variability and no correlation with age, sex and anthropometric parameters in healthy children. These indices are useful for detection of acute changes in bronchomotor tonus in asthmatics - V(PTEF)/V(E) = 36.1 +/- 6.6% vs. 32.6 +/- 6.2% (methacholine) vs. 37.4 +/- 7.5% (salbutamol) and T(PTEF)/T(E) = 34.2 +/- 6.2% vs. 28.6 +/- 7.8% vs. 35.3 +/- 7.5%, resp. (P < 0.05 everywhere; n = 34) as well as for discriminating a group of subjects with AFO vs. controls (V(PTEF)/V(E) = 30.9 +/- 6.5% vs. 35.3 +/- 8.0%; P = 0.005, and T(PTEF)/T(E) = 29.0 +/- 6.7% vs. 32.8 +/- 7.6%; P = 0.016). The evaluation of the area under the ROC curves (AUC) in the asthmatic group showed weak discriminative capacity of T(PTEF)/T(E) and V(PTEF)/V(E) in comparison to FEV1 (AUC of T(PTEF)/T(E) = 0.62; 95%CI 0.51-0.74). CONCLUSIONS: Tidal breathing parameters could add insight t.o the functional profile but are not capable of substituting forced expiration regarding detection of overt airflow obstruction in school-age children.

Adolescent↗

Cardiovascular and dyspnea response to six-minute and shuttle walk tests in COPD patients.

UNLABELLED: Previous studies focusing on the changes of heart rate, systolic blood pressure and dyspnea caused by the six-minute (6MWT) and shuttle walking distance tests (ISWT) have produced conflicting data. The present study aims at comparing the cardiovascular and dyspnea responses to 6MWT and ISWT in patients with chronic obstructive pulmonary disease (COPD). Twenty patients with clinically stable COPD (age, 56 +/- 9 yrs; BMI, 27.8 +/- 7.7 kg.m(-2); FEV1%pred, 42 +/- 19%; mean +/- Sx) performed three 6MWTs and two ISWTs using standardised protocols. The distances walked in the third 6MWT and second ISWT were 458 +/- 105 and 365 +/- 116 m, respectively. There was a significant correlation between the distances covered in the two tests (r = 0.87; p < 0.001). The 6MWT and ISWT showed similar correlation coefficients with the Baseline Dyspnea Index (r = 0.86; p < 0.001 and r = 0.76; p < 0.001), the Clinical Symptom Scale (r= -0.72; p < 0.001 and r= -0.55; p = 0.011), FEV1 L (r = 0.36; NS and r = 0.30; NS), PImax (r = 0.59; p < 0.008 and r = 0.60; p = 0.001) and the mean pulmonary artery pressure, Doppler echocardiography (r= -0.51; p < 0.029 and r = -0.51; p = 0.032). Although the response to ISWT tended to be greater, we found no statistically significant differences between the two tests in the changes of heart rate (HR), systolic blood pressure (SBP) and dyspnea (Borg) (deltaHR, 17.9 +/- 13.4 vs 23.8 +/- 15.4; deltaSBP, 7.7 +/- 14.6 vs 13.0 +/- 17.0 and deltaBorg, 1.7 +/- 1.1 vs 2.2 +/- 0.9; NS). CONCLUSION: The cardiovascular and dyspnea response caused by ISWT is greater (but statistically not significant) than that generated by 6MWT. The more limited the functional capacity of COPD patients the more similar the response generated by 6MWT and ISWT.

Blood Pressure↗