PubMed Health⌕ Search

Biomedical subjects

Vladimir V Popov

Publications and source records attributed to Vladimir V Popov.

5 recordsLinked to original sources

Monaural and binaural hearing directivity in the bottlenose dolphin: evoked-potential study.

Hearing thresholds as a function of sound-source azimuth were measured in bottlenose dolphins using an auditory evoked potential (AEP) technique. AEP recording from a region next to the ear allowed recording monaural responses. Thus, a monaural directivity diagram (a threshold-vs-azimuth function) was obtained. For comparison, binaural AEP components were recorded from the vertex to get standard binaural directivity diagrams. Both monaural and binaural diagrams were obtained at frequencies ranging from 8 to 128 kHz in quarter-octave steps. At all frequencies, the monaural diagram demonstrated asymmetry manifesting itself as: (1) lower thresholds at the ipsilateral azimuth as compared to the symmetrical contralateral azimuth and (2) ipsilateral shift of the lowest-threshold point. The directivity index increased with frequency: at the ipsilateral side it rose from 4.7 to 17.8 dB from 11.2 to 128 kHz, and from 10.5 to 15.6 dB at the contralateral side. The lowest-threshold azimuth shifted from 0 degrees at 90-128 kHz to 22.5 degrees at 8-11.2 kHz. The frequency-dependent variation of the lowest-threshold azimuth indicates the presence of two sound-receiving apertures at each head side: a high-frequency aperture with the axis directed frontally, and a low-frequency aperture with the axis directed laterally.

Acoustic Stimulation↗

Nonconstant quality of auditory filters in the porpoises, Phocoena phocoena and Neophocaena phocaenoides (Cetacea, Phocoenidae).

Simultaneous tone-tone masking in conjunction with the envelope-following response (EFR) recording was used to obtain tuning curves in porpoises Phocoena phocoena and Neophocaena phocaenoides asiaeorientalis. The EFR was evoked by amplitude-modulated probes with a modulation rate of 1000 Hz and carrier frequencies from 22.5 to 140 kHz. Equivalent rectangular quality QERB of the obtained tuning curves varied from 8.3-8.6 at lower (22.5-32 kHz) probe frequencies to 44.8-47.4 at high (128-140 kHz) frequencies. The QERB dependence on probe frequency could be approximated by regression lines with a slope of 0.83 to 0.86 in log-log scale, which corresponded to almost frequency-proportional quality and almost constant bandwidth of 3-4 kHz. Thus, the frequency representation in the porpoise auditory system is much closer to a constant-bandwidth rather that to a constant-quality manner.

Animals↗

Rippled-spectrum resolution dependence on masker-to-probe ratio.

Resolution of rippled sound spectrum (probe) in the presence of additional noise band (masker) was studied as a function of masker-to-probe ratio and sound level in normal listeners. The probe bands were 0.5-oct wide (ERB) centered at 2 kHz; the masker band either coincided with the probe (on-frequency masker), or was 3/4 octaves below (low-frequency masker), or 3/4 octaves above the probe (high-frequency masker). Ripple-density resolution in the probe band was measured by finding the highest ripple density at which an interchange of ripple peaks and valleys was detectable (the phase-reversal test). (i) The effect of the low-frequency masker increased (resolution decreased) when masker-to-probe ratio changed from -25 dB to +20 dB; the effect increased (resolution decreased) with sound level increase. (ii) The effect of the on-frequency masker steeply increased (resolution abruptly decreased) when masker-to-probe ratio exceeded 0 dB; the effect was little dependent on sound level. (iii) The high-frequency masker was little effective unless the masker-to-probe ratio reached 30-40 dB; the effect increased (resolution decreased) with sound level decrease. Thus, different position of the masker band relative to the probe resulted in qualitatively different kinds of spectrum-pattern resolution dependence on both the masker-to-probe ratio and sound level.

Acoustic Stimulation↗

Rippled-spectrum resolution dependence on level.

Rippled-density resolution of a rippled sound spectrum (probe band) in both the presence and absence of another band (masker) was studied as a function of sound level in normal listeners. The resolvable ripple density in the probe band was measured by finding the highest ripple density at which an interchange of ripple peak and valley positions was detectable (the phase-reversal test). Probe bands were 0.5 oct wide with center frequencies of 1, 2, and 4 kHz. In the control condition (no masker), the ripple-density resolution was almost independent of sound level within a range of 40-90 dB SPL. When an on-frequency masker coincided with the probe band (that resulted in reduced ripple depth), resolution decreased slightly relative to the control condition but remained little dependent on level. With an off-frequency low-side masker, the ripple-density resolution was a little less than in the control but almost independent of level within a range of 40-60 dB SPL and progressively decreased with level increase from 70 to 90 dB SPL. The dependence on level was qualitatively similar at all probe frequencies and at various widths and positions of the low-side off-frequency masker band.

Acoustic Stimulation↗