PubMed Health⌕ Search

Biomedical subjects

Volker Dörnberger

Publications and source records attributed to Volker Dörnberger.

4 recordsLinked to original sources

Long-term experience with subcutaneous ICD leads: a comparison among three different types of subcutaneous leads.

ICDs provide protection against sudden cardiac death in patients with life-threatening arrhythmias. Nevertheless, efficacy of defibrillation remains an important issue to guarantee the future safety of patients who receive an ICD. There is a significant number of patients who need an additional subcutaneous lead to obtain a defibrillation safety margin of at least 10 J between the maximum output of the ICD and the energy needed for ventricular defibrillation. However, few data exists about the long-term performance of different types of subcutaneous leads. Therefore, the aim of this study was to analyze the long-term experience with three different types of subcutaneous leads. The study included 132 patients (109 men, 23 women; mean age 59.8 years [SD +/- 10.7 years]). All of them received a subcutaneous lead in addition to a single chamber or dual chamber ICD between October 1990 and April 2002. Two patients received a second subcutaneous lead after the first lead had been removed so that a total of 134 subcutaneous leads were evaluated. Inclusion criteria for the implantation of an additional subcutaneous lead were (1) unsuccessful ventricular defibrillation at implant without a subcutaneous lead, (2) insufficient safety margin (< 10 J) between the maximum output of the ICD and the energy needed for ventricular defibrillation, or (3) clinical evaluation of a new subcutaneous lead (Medtronic 13014). There were no significant differences between the three study groups with regard to age, sex, underlying cardiac disease, left ventricular ejection fraction, NYHA class assessment and clinical arrhythmia. The results of the DFT testing during follow-up (prehospital discharge test and 1 and 3 years) were compared to the baseline value obtained during the implantation procedure. All lead related complications were analyzed. Eighty-two single element subcutaneous array electrodes (SQ-A1), 31 subcutaneous three-finger electrodes (SQ-A3), and 21 subcutaneous patch electrodes (SQ-P) were implanted during the study period. The median follow-up was 1,499 days (25th percentile: 798 days, 75th percentile: 1,976 days) in the SQ-A1 group, 2,209 days (25th percentile: 1,242 days, 75th percentile: 2,710 days) in the SQ-A3 group, and 1,419 days (25th percentile: 787 days, 75th percentile: 2,838 days) in the SQ-P group. None of the three groups had a significant change of the DFT during follow-up compared to baseline. Major complications occurred in six (7.3%) patients in group SQ-A1 and in two (9.5%) patients in group SQ-P. There were no major complications in group SQ-A3. Kaplan-Meier curves analyzing freedom from subcutaneous lead related complications did not show a significant difference between the three study groups (P = 0.16). SQ-A1, SQ-A3, and SQ-P leads provide stable DFTs during long-term follow-up. Major complications are rare. However, a careful follow-up including chest radiographs at regular intervals is needed to detect potentially fatal complications like lead fractures.

Defibrillators, Implantable↗

Scimitar syndrome: morphological diagnosis and assessment of hemodynamic significance by magnetic resonance imaging.

Scimitar syndrome has a variable presentation depending on the age at which the diagnosis is made. We report a case of a young woman (age 18 years) with suspected right pulmonary hypoplasia in whom a scimitar syndrome was diagnosed. Using MRI morphological findings and hemodynamic significance of the syndrome were assessed. Left-to-right shunt was calculated from blood flow measurements performed in the ascending aorta, the main pulmonary artery, and the aberrant scimitar vein.

Adolescent↗

Efficacy of metoprolol and sotalol in the prevention of recurrences of sustained ventricular tachyarrhythmias in patients with an implantable cardioverter defibrillator.

ICDs provide protection against sudden cardiac death in patients with life-threatening ventricular arrhythmias. Nevertheless, most ICD recipients receive adjunctive antiarrhythmic drug therapy to reduce the number of recurrent episodes and ICD discharges. The aim of the study was to compare the efficacy of metoprolol and d,l-sotalol in preventing VT/VF recurrences in patients with an ICD in a prospective, randomized trial. One hundred patients (83 men, 17 women; mean age 59 years, SD +/- 11 years) were randomized to receive metoprolol or sotalol after implantation of an ICD. There were no significant differences between the two groups with regard to age, sex, underlying cardiac disease, left ventricular ejection fraction, NYHA class assessment and clinical arrhythmia. The median follow-up was 728 days (25th percentile: 530 days, 75th percentile: 943 days) in the metoprolol group and 727 days (25th percentile: 472 days, 75th percentile: 1,223 days) in the sotalol group (P = 0.52). Thirty-three patients treated with metoprolol and 30 patients receiving sotalol had at least one episode during the follow-up. Event-free survival curves were generated for the two treatment arms using the Kaplan-Meier method and showed no significant difference (P = 0.68). Eight patients treated with metoprolol and six patients treated with sotalol died during follow-up. Total mortality was not significantly different between the two study groups (P = 0.43). Metoprolol is as efficacious as sotalol in preventing VT/VF recurrences in patients with an ICD.

Defibrillators, Implantable↗

Is it safe to program a long tachycardia detection interval?

Implantable cardioverter defibrillator (ICD) therapy is used frequently in patients with "slow" ventricular tachycardia (VT). Hence, the tachycardia detection interval is programmed within the range of the physiologic heart rate, but this may cause serious problems. If a fast VT is converted to sinus tachycardia with a cycle length shorter than the tachycardia detection interval, the episode is not terminated and the success counter is not reset. If this happens repeatedly, therapies will be exhausted without termination of the episode. If VT recurs within such an episode, it will not be treated. This report describes a patient who died suddenly in a scenario similar to the one described. Although all documented VT/ventricular fibrillation episodes were terminated by the device, the episode was not terminated because of the ongoing supraventricular tachycardia. Therefore, no further therapies were available and the patient probably died of fast untreated VT. Programming of a long tachycardia detection interval is dangerous in currently available ICDs.

Aged↗