PubMed Health⌕ Search

Biomedical subjects

Volker M Gorenflo

Publications and source records attributed to Volker M Gorenflo.

5 recordsLinked to original sources

Accelerating perfusion process optimization by scanning non-steady-state responses.

Perfusion processes provide consistent culture conditions, high productivity and low product residence times. However, process development can be slow due to the 1 week or more required to reach each steady state. The objective of this work was to accelerate process development in perfusion cultures by scanning non-steady-state transient responses to qualitatively predict steady-state performance. The method was tested using a shift in temperature every 3 days, scanned down by steps of 2 degrees C from 37 degrees C to 31 degrees C, then scanned up to 37 degrees C. Higher t-PA concentrations were predicted at lower temperatures, confirmed by subsequent pseudo-steady-state results. In most cases, transient values on the 3rd day were in close concordance with pseudo-steady-state values. To further accelerate process development, transient scanning was applied to small-scale, non-instrumented cultures. Similar results were obtained, although quantitative t-PA values were 15-30 times lower than in high cell density perfusion cultures. The method was further explored by investigating 1 day transient shifts in temperature where more variability was observed, suggesting that the cells were still adapting to the new environment. Nonetheless, the overall response again qualitatively predicted the pseudo-steady-state temperature response. Use of transient scanning in conjunction with pseudo-steady-state verification and refinement of optimal results could reduce process development time to a third or less of comparable steady-state-based optimization.

Animals↗

Optical analysis of perfusion bioreactor cell concentration in an acoustic separator.

Automated monitoring of cell concentration in perfusion bioprocesses facilitates the maintenance of constant cell specific perfusion rates. However, most on-line measuring devices are relatively complex and foul as the culture progresses. A simple external optical sensor was developed using the transparent glass walls of acoustic separators for automated optical analysis of their contents. For each measurement, the separator was filled by an automated pumping system with triplicate representative bioreactor samples that were optically analyzed and the device returned to perfusion operation within approximately 1 or 2 min. Chinese hamster ovary cell concentrations, ranging from 5 x 10(5) to 2 x 10(7) cells/mL, were highly correlated (R(2) = 0.99) with the 90 degrees scattered light response. Since the device was operated externally, it did not complicate bioreactor sterilization or cleaning. Viability was not optically analyzed, but this information was not required between manual samples of a properly operated perfusion process. Using single-point recalibration based on routine off-line samples, this external optical system remained effective during a 4-month perfusion run, thus providing a non-invasive and easily maintained on-line cell concentration monitoring system to improve the control of perfusion bioreactors.

Acoustics↗

Characterization and optimization of acoustic filter performance by experimental design methodology.

Acoustic cell filters operate at high separation efficiencies with minimal fouling and have provided a practical alternative for up to 200 L/d perfusion cultures. However, the operation of cell retention systems depends on several settings that should be adjusted depending on the cell concentration and perfusion rate. The impact of operating variables on the separation efficiency performance of a 10-L acoustic separator was characterized using a factorial design of experiments. For the recirculation mode of separator operation, bioreactor cell concentration, perfusion rate, power input, stop time and recirculation ratio were studied using a fractional factorial 2(5-1) design, augmented with axial and center point runs. One complete replicate of the experiment was carried out, consisting of 32 more runs, at 8 runs per day. Separation efficiency was the primary response and it was fitted by a second-order model using restricted maximum likelihood estimation. By backward elimination, the model equation for both experiments was reduced to 14 significant terms. The response surface model for the separation efficiency was tested using additional independent data to check the accuracy of its predictions, to explore robust operation ranges and to optimize separator performance. A recirculation ratio of 1.5 and a stop time of 2 s improved the separator performance over a wide range of separator operation. At power input of 5 W the broad range of robust high SE performance (95% or higher) was raised to over 8 L/d. The reproducible model testing results over a total period of 3 months illustrate both the stable separator performance and the applicability of the model developed to long-term perfusion cultures.

Acoustics↗

Scale-up and optimization of an acoustic filter for 200 L/day perfusion of a CHO cell culture.

Acoustic cell retention devices have provided a practical alternative for up to 50 L/day perfusion cultures but further scale-up has been limited. A novel temperature-controlled and larger-scale acoustic separator was evaluated at up to 400 L/day for a 10(7) CHO cell/mL perfusion culture using a 100-L bioreactor that produced up to 34 g/day recombinant protein. The increased active volume of this scaled-up separator was divided into four parallel compartments for improved fluid dynamics. Operational settings of the acoustic separator were optimized and the limits of robust operations explored. The performance was not influenced over wide ranges of duty cycle stop and run times. The maximum performance of 96% separation efficiency at 200 L/day was obtained by setting the separator temperature to 35.1 degrees C, the recirculation rate to three times the harvest rate, and the power to 90 W. While there was no detectable effect on culture viability, viable cells were selectively retained, especially at 50 L/day, where there was a 5-fold higher nonviable washout efficiency. Overall, the new temperature-controlled and scaled-up separator design performed reliably in a way similar to smaller-scale acoustic separators. These results provide strong support for the feasibility of much greater scale-up of acoustic separations.

Acoustics↗

Optimization of an acoustic cell filter with a novel air-backflush system.

Increasing worldwide demand for mammalian cell production capacity will likely be partially satisfied by a greater use of higher volumetric productivity perfusion processes. An important additional component of any perfusion system is the cell retention device that can be based on filtration, sedimentation, and/or acoustic technologies. A common concern with these systems is that pumping and transient exposure to suboptimal medium conditions may damage the cells or influence the product quality. A novel air-backflush mode of operating an acoustic cell separator was developed in which an injection of bioreactor air downstream of the separator periodically returned the captured cells to the reactor, allowing separation to resume within 20 s. This mode of operation eliminated the need to pump the cells and allows the selection of a residence time in the separator depending on the sensitivity of the cell line. The air-backflush mode of operating a 10L acoustic separator was systematically tested at 10(7) cells/mL to define reliable ranges of operation. Consistent separation performance was obtained for wide ranges of cooling airflow rates from 0 to 15 L/min and for backflush frequencies between 10 and 40 h(-1). The separator performance was optimized at a perfusion rate of 10 L/day to obtain a maximum separation efficiency of 92 +/- 0.3%. This was achieved by increasing the power setting to 8 W and using duty cycle stop and run times of 4.5 and 45 s, respectively. Acoustic cell separation with air backflush was successfully applied over a 110 day CHO cell perfusion culture at 10(7) cells/mL and 95% viability.

Acoustics↗