PubMed Health⌕ Search

Biomedical subjects

W A Bautz

Publications and source records attributed to W A Bautz.

14 recordsLinked to original sources

[How to cope with the demands of the new "Approbation Regulation" (AR) by radiology-related interdisciplinary courses. The Erlangen model].

BACKGROUND: To create radiology-related interdisciplinary programs for the undergraduate education in terms of the new "Approbation Regulation". MATERIAL AND METHODS: Medical students developed in collaboration with radiologists and clinical partners virtual, radiology-related interdisciplinary training courses for different fields. Students and teachers evaluated the acceptance of the programs' structure and content as well as the possibility to replace the radiologist partly during interdisciplinary lessons. RESULTS: Six target group oriented virtual, radiology-related interdisciplinary training courses were developed which will relieve the implementation of the new AR's demands for more interdisciplinary education in small groups and the dreaded shortage of personnel. CONCLUSION: By the use of web- and CDRom-based interdisciplinary course models different fields of medicine and diagnostic radiology can be bridged in the sense of the new AR's demands as well as manpower in radiology can be saved.

CD-ROM↗

[HNORAD].

BACKGROUND: New media are gaining importance in undergraduate as well as postgraduate and continued medical education. We aimed to create an interactive educational program for imaging diseases of the ear, nose and throat (ENT). MATERIALS AND METHODS: Cases and images representing clinical routine were collected, arranged by content and graphically presented according to instructional criteria. Undergraduate students participating in the project used an authoring system to generate case studies, which were then published at http://www.HNORAD.de. RESULTS: HNORAD is an interdisciplinary teaching program offering more than 100 classical disease presentations. Three systematic indices offer a choice of instructional approach. Apart from typical images, the information presented includes patient history, clinical findings, imaging findings as described by a board-qualified radiologist, diagnosis, differential diagnosis and internet links. Elements of the radiologist's report are linked with the images in such a way that the structure or finding described can be interactively highlighted. An evaluation index allows proficiency testing in self study and as a part of taught courses. CONCLUSION: HNORAD is a valuable resource for students, ENT surgeons and radiologists at the undergraduate, postgraduate and CME level for self study as well as for course work.

Computer-Assisted Instruction↗

[Quality improvement of resources in radiology on the internet].

PURPOSE: Categorization and evaluation of online teaching files in radiology by representative members of the target group to make the specific search for adequate programs more effective. MATERIALS AND METHODS: A representative team of board qualified radiologists, residents and medical students performed a basic search for radiology teaching files on the Internet using search machines, international mailing lists and link lists to collections of national and international radiological societies and departments. The programs were categorized by language, modality, target group and special features, such as qualification for CME-accreditation. For final evaluation and ranking of the detected files, a questionnaire was developed to assess completeness, image quality, page loading time, layout, orientation, interactivity, annotation and maintenance. The results were stored in an Access database on a web server. A query form in HTML format, including the parameters described above, was made accessible to the online user. RESULTS: A search machine for radiological teaching files (RadList/Entity-link List) was made available online ( www.tnt-radiology.de/radlist and www.tnt-radiology.de/entitylinklist ). A submitted request calls a cgi script that searches the database for the appropriate sites according to the individual search parameters selected by the user. The list of matching URLs is returned to the user as HTML page. Evaluating the single sites by applying the criteria listed above contributed to the quality assurance of the radiological teaching resources on the Internet. CONCLUSION: Adapting a new Internet interface to the particular needs of the user allows a more effective access to specific radiological teaching files online. RadList/Entity-link List ( www.tnt-radiology.de/radlist and www.tnt-radiology.de/entitylinklist ) is conducive to quality improvement and benefits users as well as authors of radiological teaching files on the Internet.

Computer-Assisted Instruction↗

Bilateral orbital tumour as the presentation of mammographically occult breast cancer.

We report a rare case of bilateral orbital metastases as the presentation in a 63-year-old woman. Biopsy of a diffusely infiltrated medial rectus muscle suggested metastatic adenocarcinoma. Investigation revealed a palpable mass of the right breast not shown on mammography or sonography. Invasive lobular carcinoma was found at core-needle biopsy with histological features identical to those of the orbital lesion. Metastases to the extraocular muscles are uncommon, particularly as the initial abnormality in the absence of disseminated disease.

Breast Neoplasms↗

[Web-based training in radiology - student course in the Virtual University of Bavaria].

PURPOSE: The ninth version of the licensing regulation for medical doctors (Approbation Regulation (AR)) sets a benchmark in terms of practical experience, interdigitation of preclinical and clinical studies, interdisciplinary approach, economic efficiency, independence of students, added new teaching and learning modalities, and ongoing evaluation of the progress of the medical students. It is the aim to implement these major points of the AR in a model course for diagnostic radiology and radiation protection within the scope of the Virtual University of Bavaria and test them in practice. MATERIALS AND METHODS: In cooperation with residents and board certified radiologists, students developed the virtual course "Web-Based Training (WBT) Radiology" in diagnostic radiology and radiation protection for students in the first clinical semester. A representative target group taken from the student body was asked about the options to get access to the World Wide Web (Internet), and the satisfaction concerning configuration and content of the newly developed program. A comparison was made between the results of the final examination taken by students who made use of the virtual course in addition to conventional lessons and taken by students who did not subscribe to the virtual course and exclusively relied on conventional lessons. In addition, a pilot study was conducted in the winter semester 2002/03, which compared students taking either the traditional lessons or the new virtual course on the Internet. RESULTS: The virtual course-model had test results with a positive trend. All targeted students had Internet access. Constructive criticism was immediately implemented and contributed to rapid optimization. The learning success of the additive or alternative virtual course was in no way less than the learning success achieved with the conventional course. CONCLUSION: The learning success as measure of quality in teaching and the acceptance by students and teachers justify the continuation of this course model and its expansion. Besides enabling the learning in small study groups; the course "WBT Radiology" might not only help implementing the major points of the new AR but might also complement any deficiencies in the current education. Economic aspects may encourage their implementations.

Computer-Assisted Instruction↗

[CT-angiography of the carotid artery: First results with a novel 16-slice-spiral-CT scanner].

PURPOSE: To evaluate a novel multislice CT system (16-slice-spiral-CT scanner) for the diagnosis of carotid artery stenosis. MATERIAL AND METHODS: Five patients with symptomatic atherosclerotic disease of the carotid arteries were examined with a 16- slice-spiral-CT scanner. Collimation was 16 x 0.75 mm, table speed 36 mm/s (pitch of 1.5), rotation time 0.5 s, tube current was 160 eff.mAs at 120 kV. 60 ml of contrast material were injected with a power injector followed by a saline flush. The start delay was measured with test bolus method (20 ml CM). Interactive multiplanar reformation (iMPR) and thin slab MIP as well as volume rendering were used for image evaluation and presentation. RESULTS: Scan time was 9 s for a range of 300 mm. This allowed imaging the whole length of the carotid artery (aortic arch to circle of Willis) in a true arterial phase. Pulsation artefacts did not impair the evaluation of the vessels at the level of the aortic arch. Overall image quality of both "source images" and 3D-reconstructions was excellent, due to a reduced voxel size of 0.03 mm (3). Image evaluation and postprocessing (iMPR, MIP) was done within 15 min. iMPR was highly accurate for demonstrating plaque morphology and determining the percentage of the stenosis. CONCLUSION: For the first time, true arterial phase images of the entire carotid artery with high spatial resolution could be acquired using a 16-slice-spiral-CT scanner. This method offers the potential to replace catheter angiography in the evaluation of carotid artery stenosis.

Blood Flow Velocity↗

Direct MR arthrography of the shoulder: 2D vs. 3D gradient-echo imaging.

The aim of this study was to determine the value of a fat suppressed 3D gradient-echo sequence (GRE) data set in comparison to a 2D GRE sequence in direct MR arthrography of the shoulder. For this purpose we examined 50 consecutive patients with subacute or chronic disorders of the shoulder using a 1.5 T scanner: Transverse T1-weighted 2D (slice thickness 4 mm) and 3D GRE (slice thickness 1.5 mm reconstructed from 3 mm), oblique coronal T2- and T1-weighted turbo spin-echo (TSE) and sagittal T1-weighted TSE with fat saturation were applied. Visual image analysis of anatomical and pathological structures was performed by two independent observers. A correlation to surgical results was available in 21 patients. Transverse GRE sequences were well suited for analysis of the anterior/posterior labrum, the middle glenohumeral ligament, and cartilage. 3D GRE with fat suppression was slightly superior to 2D GRE without fat suppression in the evaluation of the anterior/posterior labrum, and the middle glenohumeral ligament, whereas for cartilage no significant differences were found between both sequences. Concerning pathological findings, in most of the cases 2D delivered the same results as 3D. In conclusion, a T1-weighted 3D GRE data set with fat saturation in transverse orientation may be useful for evaluation of the anterior/posterior labrum, and the middle glenohumeral ligament. However, similar measured slice thickness of 3 mm-even if interpolated to 1.5 mm-compared to a 2D sequence with 4 mm does not provide significant diagnostic advantages.

Adolescent↗

A low-field MR system in acute traumatological imaging in radiology. Technical note.

PURPOSE: In this paper initial clinical observations with the application of a new low-field MR system in acute musculoskeletal imaging in radiology are presented. MATERIALS AND METHODS: This system is designed as a three-sided open permanent magnet with a revolving table. Main magnetic field strength is 0.2 T, maximal gradient field strength 20 mT/m, and minimal gradient rise time is 800 microseconds. First clinical experiences in 25 patients with acute trauma of peripheral joints were obtained. The following sequences were applied: gradient-echo (GRE) STIR, T1-weighted spin-echo, and PD- and T2-weighted turbo spin-echo. Correlation with the findings of high-field MR (1.5 T), plain radiograms (including stress views), CT or ultrasound was available in each patient confirming the low-field diagnoses. Furthermore, phantom measurements were performed to verify the spatial resolution of the system for some sequences with typical measurement parameters. DISCUSSION: This low-field system has several advantages: fast and economic installation, limited required space, easy operation, and high patient comfort. The medical benefit of such a system integrated in the traumatological suite of a radiological department seems to be evident due to the impact on the early initiation of the correct therapy which avoids additional diagnostic procedures and therefore may reduce costs. Implementation of such a system may be useful, if installation of an additional high-field scanner is not possible due to economic considerations.

Adolescent↗

Dose reduction in computed tomography by attenuation-based on-line modulation of tube current: evaluation of six anatomical regions.

This study investigated the potential of attenuation-based on-line modulation of tube current to reduce the dose of computed tomography (in milliamperes) without loss in image quality. The dose can be reduced for non-circular patient cross-sections by reducing the tube current at the angular positions at which the diameter through the patient diameter is smallest. We investigated a new technical approach with attenuation-based on-line modulation of tube current. Computed tomographic projection data were analyzed to determine the optimal milliampere values for each projection angle in real time, instead of performing prior measurements with localizer radiographs. We compared image quality, noise pattern, and dose for standard scans and for scans with attenuation-based on-line modulation of tube current in a group of 30 radiation therapy patients. Six different anatomical regions were examined: head, shoulder, thorax, abdomen, pelvis, and extremities (knee). Image quality was evaluated by four radiologists in a blinded fashion. We found the dose to be reduced typically by 15-50 %. In general, no deterioration in image quality was observed. Thus the dose in computed tomography be reduced substantially by technical measures without sacrificing image quality. Attenuation-based on-line modulation of tube current is an efficient and practical means for this.

Humans↗

2D and 3D visualisation of head and neck tumours from spiral-CT data.

PURPOSE: This paper intends to demonstrate the possibilities of two- and three-dimensional visualisation methods from spiral-CT data sets in the head and neck region and demonstrates their value based on various studies. MATERIAL AND METHODS: The scanner was a Somatom PLUS 4 (Siemens, Forchheim/Germany). The patients were scanned using a slice thickness of 3 mm and a table feed of 5 mm (pitch 1,6). The images were reconstructed with an increment of 1 mm. Contrast agent (150 ml) was applied intravenously with a flow of 2.5 ml/s and a start delay of 80 s. In one study the start delay was 20 s in order to visualise the carotid arteries (extracranial aneurysm). Volumetric data sets were postprocessed with 'Vitrea' and 'VoxelView' (Vital Images) volume rendering software on a Silicon Graphics O2 workstation (virtual laryngoscopy). Multiplanar reformation and colour-coded 3D-reconstruction were done on a Prominence workstation (Siemens/Forchheim/Germany). RESULTS: In every region of the head and neck MPRs are useful as additional planes (with the exception of the hypopharynx and the larynx), SSDs are always useful if there is extensive bony destruction (skull, spine, skeleton larynx). Colour-coded three-dimensional reformations may be done for extensive tumours and before multi-specialty surgery. Perspective volume rendering is already in use for virtual endoscopy of the paranasal sinuses and the virtual laryngoscopy. In temporal bone evaluation, perspective volume rendering is a new and promising method of the future to assess the inner ear. SUMMARY: Two- and three-dimensional displays are used to visualise pathological findings in their topographic relation to anatomical leading structures. Thus, the radiologist can point out to the clinician the pathological findings by some essential images without having to demonstrate all axial slices.

Aneurysm↗

[A hybrid technique for the automatic floating table MRA of peripheral arteries using a dedicated phased-array coil combination].

PURPOSE: We introduce a hybrid technique which allows a high resolution MRA of the peripheral arteries with a dedicated phased-array coil using the floating table technique. MATERIALS AND METHODS: Five patients with peripheral arterial occlusive disease were examined within one week with i.a. DSA and MRA using the hybrid technique. MRA examinations were done on a 1.5 T system. At first, pelvic arteries were examined in a single step mode applying the CareBolus technique. Subsequently, thighs and lower legs were examined using the floating table mode. 125 vascular segments were evaluated. RESULTS: The hybrid technique proved to be robust and could be performed in each case. Mean examination time was about 30 min. For 117 vascular segments no difference was found between i.a. DSA and MRA. Three segments revealed a higher grade of stenosis in DSA than in MRA, five segments were graded higher in MRA than in DSA. Occlusions were visualized identically in both methods. Venous overlap had no relevant effects on image evaluation. CONCLUSIONS: This hybrid technique in combination with phased-array coils allows a high resolution MRA of the peripheral arteries with very good image quality. If future studies confirm reduced venous overlap, this method may be an alternative also for users of the floating table MRA with the body resonator.

Arterial Occlusive Diseases↗

Dose reduction in CT by on-line tube current control: principles and validation on phantoms and cadavers.

We investigated approaches to reducing the dose in CT without impairing image quality. Dose can be reduced for non-circular object cross-sections without a significant increase in noise if X-ray tube current is reduced at angular tube positions where the X-ray attenuation by the patients is small. We investigated different schemes of current modulation during tube rotation by simulation and phantom measurements. Both pre-programmed sinusoidal modulation functions and attenuation-based on-line control of the tube current were evaluated. All relevant scan parameters were varied, including constraints such as the maximum modulation amplitude. A circular, an elliptical and two oval water phantoms were used. Results were validated on six cadavers. Dose reduction of 10-45% was obtained both in simulations and in measurements for the different non-circular phantom geometries and current modulation algorithms without an increase in pixel noise values. On-line attenuation-based control yielded higher reductions than modulation by a sinusoidal curve. The maximal dose reduction predicted any simulations could not be achieved due to limits in the modulation amplitude. In cadaver studies, a reduction of typically 20-40% was achieved for the body and about 10% for the head. Variations of our technique are possible; a slight increase in nominal tube current for high-attenuation projections combined with attenuation-based current modulation still yields significant dose reduction, but also a reduction in the structured noise that may obscure diagnostic details. We conclude that a significant reduction in dose can be achieved by tube current modulation without compromising image quality. Attenuation-based on-line control and a modulation amplitude of at least 90% should be employed.

Cadaver↗