PubMed Health⌕ Search

Biomedical subjects

W A Brantley

Publications and source records attributed to W A Brantley.

At least 37 records · Page 2Linked to original sources

In vitro corrosion resistance of high-palladium dental casting alloys.

OBJECTIVE: The objective of this study was to characterize the in vitro corrosion behavior of five high-palladium dental alloys in two media using a potentiodynamic polarization technique. METHODS: Potentiodynamic cyclic polarization between -1000 and +1000 mV (SCE), 12 h open-circuit potential measurement, and linear polarization were performed on cast specimens of three Pd-Cu-Ga alloys and two Pd-Ga alloys in deaerated 0.09% NaCl solution and Fusayama artificial saliva at 37 degrees C. Zero-current potential, corrosion current density, open-circuit potential, and polarization resistance were determined. The Kruskal-Wallis test and the Mann-Whitney U-test were used to analyze the numeric findings. RESULTS: The Pd-Cu-Ga and Pd-Ga alloys in both the as-cast and heat-treated conditions showed spontaneous passive behavior under electrochemical conditions similar to those in the oral environment. The Pd-Cu-Ga alloys Liberty and Spartan Plus exhibited increased activity in the Fusayama artificial saliva after the porcelain-firing heat treatment, which may have arisen from internal oxidation of casting defects. Heat-treated Freedom Plus had an unstable oxide film to form on the surface during anodic polarization and may have a limited tendency for pitting corrosion in the Fusayama artificial saliva. The two heat-treated Pd-Ga alloys remained passive in the test media. As a group, the high-palladium alloys exhibited satisfactory corrosion resistance. SIGNIFICANCE: Corrosion of high-palladium alloys in the oral environment involves a release of ions that is related to their biocompatibility. Knowledge of the in vitro corrosion behavior of these alloys may lead to better understanding of any biologically adverse effects in vivo.

Corrosion↗

TEM analysis of tweed structure in high-palladium dental alloys.

Transmission electron microscopy and convergent-beam electron diffraction were used to study three high-palladium dental alloys: an as-cast Pd-Ga alloy, a cast Pd-Cu-Ga alloy aged at room temperature for over 5 years, and a cast Pd-Cu-Ga alloy annealed at 1023 K for 2 h and slowly cooled to room temperature. Bands containing a tweed structure in the Pd-Ga alloy were 120degrees twins with (1 1 0 mirror planes. Within these bands the alloy had a face-centered tetragonal structure with a c/a ratio of 1.03. The aged Pd-Cu-Ga alloy contained a larger amount of tweed structure than the original as-cast alloy, along with randomly oriented bands and thin lath-like regions. The annealed Pd-Cu-Ga alloy contained rectangular particles of a secondary phase that may be Pd2Ga, Pd5Ga2 or Pd13Ga5. The microtwinned band structure relieves the strain energy arising from transformation of the f.c.c. palladium solid solution on cooling.

Journal Article↗

Effects of three soldering techniques on the strength of high-palladium alloy solder joints.

STATEMENT OF PROBLEM: Little information is available on the optimum technique for soldering high-palladium alloys, which have gained considerable popularity for prosthodontic applications. PURPOSE: The objective of this study was to compare the flexural stress at the proportional limit of four noble dental alloy specimens soldered with torch, oven, and infrared-techniques. MATERIALS AND METHODS: The high-palladium alloys studied were Legacy XT (Jelenko), Freedom Plus (Jelenko), and IS 85 (Williams/Ivoclar). A gold-palladium alloy, Olympia (Jelenko), served as the control. Thirty round bars, 18 x 3 mm, were cast from each alloy, cut in half, aligned, and joined using Olympia Pre solder (Jelenko) for the gas-oxygen torch and the infrared technique and Alboro LF solder (Jelenko) for the oven technique. Each soldered bar was subjected to three-point bending, and the maximum elastic stress or strength of the solder joint was calculated at the proportional limit. Data were analyzed by two-way ANOVA and the Ryan-Einot-Gabriel-Welsch (REGW) multiple range test at the 0.05 level of significance. RESULTS: There was no significant difference between torch and oven-soldering, but both were significantly different from the infrared technique. ANOVA showed a significant difference between alloys, but this difference could not be detected with the REGW test. SEM examination of the fracture surfaces revealed grooves associated with the path of crack propagation. X-ray energy-dispersive spectroscopic analysis failed to detect copper in the solders, and there were no significant changes in the solder compositions after the melting procedures. CONCLUSIONS: All three techniques can yield satisfactory solder joints in high-palladium alloys. These joints should be well-polished to achieve optimal strength.

Analysis of Variance↗

Effects of dental laboratory processing variables and in vitro testing medium on the porcelain adherence of high-palladium casting alloys.

PURPOSE: This study assessed the effects of dental laboratory processing variables and testing medium on porcelain adherence of representative high-palladium alloys. MATERIAL AND METHODS: The processing variables were recasting two and three times, porcelain stripping with hydrofluoric acid and rebuilding, and changing the recommended oxidation procedures. The testing medium was air for these four groups and the nontreatment group. In the last group, the specimens were stored and tested in artificial saliva. The metal ceramic specimens were fractured with biaxial flexure in constant strain. The area fraction of adherent porcelain (%) was calculated with a standardized spectrometric technique. A gold-palladium alloy served as the control. RESULTS: Recasting without adding new alloy negatively affected some high-palladium alloys. Porcelain stripping did not cause a decrease in adherence of the tested alloys. The alternate oxidation treatment reduced significantly the porcelain adherence of the Au-Pd and one Pd-Cu-Ga alloy. Storage and testing in artificial saliva did not significantly affect the porcelain adherence of the alloys. The Au-Pd alloy exhibited the highest porcelain adherence.

Adhesiveness↗

Porcelain adherence vs force to failure for palladium-gallium alloys: a critique of metal-ceramic bond testing.

OBJECTIVES: The purpose of this study was to characterize the metal-ceramic bond of four commercial Pd-Ga alloys by two separate tests: porcelain adherence and bond failure force. A Pd-Ag alloy was the control. A secondary goal was to investigate a possible correlation between the percent porcelain retained and bond failure forces. METHODS: For adherence testing, five cast plates of each alloy were air abraded and oxidized. The porcelain was applied on a circular area in the center of each plate and fractured using constant-strain flexure. The area fraction of adherent porcelain (%) was calculated via a standardized spectrometric technique. Bond failure forces were measured in three-point bending using bar specimens. The modulus of elasticity of the five alloys was also measured. No attempt was made to calculate bond strength since the residual thermal stresses at the interfacial region were unknown. Data were compared via ANOVA and the Tukey multiple range test (p < 0.05). RESULTS: All failures occurred at the porcelain termination sites with no tensile fracture of the porcelain. Two Pd-Ga alloys exhibited porcelain adherence comparable with previously studied Pd-Cu-Ga alloys. There was no correlation between the porcelain adherence and the force to failure (r2 = 0.0159). Additionally, no statistically significant differences were found among the moduli of elasticity of the five alloys. SIGNIFICANCE: The new Pd-Ga alloys have been commercially introduced with little information on the quality of the bond with porcelain. The use of two different means for assessing the metal-ceramic bond provides information on the relationship of data using different experimental techniques.

Analysis of Variance↗

Transmission electron microscopic investigation of high-palladium dental casting alloys.

OBJECTIVE: The purpose of this study was to use transmission electron microscopy to examine four representative high-palladium alloys and gain insight into possible strengthening mechanisms. METHODS: Castings of two Pd-Cu-Ga alloys and two Pd-Ga alloys were thinned by jet polishing and ion milling, followed by plasma cleaning, to yield foil specimens. Multiple specimens were prepared for each alloy. Bright-field images, dark-field images and selected-area electron diffraction patterns for the alloys in the as-cast condition, after simulated porcelain-firing heat treatment, and after annealing at 980 degrees C were analyzed by standard transmission electron microscope (TEM) techniques. The overall compositions of the ultrastructures for the specimen foils were determined by conventional standardless energy-dispersive spectroscopic analyses with the TEM, and mean values of the elemental compositions were compared to the nominal alloy compositions provided by the manufacturers. RESULTS: There was generally good agreement (differences less than 2 wt%) between the overall ultrastructure composition and each nominal alloy composition, except for Protocol from which in may have been lost during casting or formed intermetallic compounds that were not detected by TEM. The same fine-scale tweed structure within parallel bands of approximately 100-200 nm width was observed for all four alloys in the as-cast condition and after simulated porcelain-firing heat treatment. The persistence of the ultrastructure in the specimens of the two Pd-Cu-Ga alloys annealed at 980 degrees C and quenched in ice water indicated very rapid formation from the palladium solid solution. The presence of ¿100¿ and ¿110¿ forbidden reflections for the <001> zone suggested that the tweed structure is ordered, although further research is necessary to establish this conclusion. SIGNIFICANCE: The presence of a similar tweed structure in both the Pd-Cu-Ga alloys and the Pd-Ga alloys of substantially lower hardness shows that some other strengthening mechanism accounts for the high hardness and strength generally observed for Pd-Cu-Ga alloys.

Copper↗

Characterization of noble metal implant cylinders: as-received cylinders and cast interfaces with noble metal alloys.

A common procedure in the fabrication of implant prostheses is the use of premade wrought cylinders in cast frameworks. Although manufacturers outline some precautions in the use of these components, detailed information about the metal interface between cylinders and cast alloys is lacking. This article, following a previous report that compared titanium-based implant cylinders used with two different classes of cast alloys, compares conventional noble metal cylinders from three different manufacturers combined with these two classes of cast noble alloys. Analysis of the as-received cylinders revealed that the implant cylinders as a group are predominantly composed of metals commonly found in noble dental alloys, namely, platinum, palladium, gold, and silver. The interfaces created by casting both high-fusing and low-fusing alloys around the cylinders exhibited a general elemental concentration variability compared with the bulk alloy regions, but continuous concentrations for shared elements suggested alloy-cylinder compatibility. Vickers hardness values, which ranged from 212 to 276 for the as-received cylinders, decreased from 12% to 43% for the various cylinders after casting. This study suggests characteristics of an ideal cast interface that include maintenance of the cylinder and casting alloy microstructures up to the interface, absence of interfacial reaction regions, lack of porosity created by volatilization of components from either alloy or the casting process, and sufficient strength to maintain anticipated loads.

Dental Alloys↗

X-ray diffraction studies of oxidized high-palladium alloys.

OBJECTIVE: The purpose of this study was to use x-ray diffraction (XRD) to obtain new information about the oxide layers on four representative oxidized high-palladium alloys. METHODS: Cast specimens of two Pd-Cu-Ga alloys and two Pd-Ga alloys, with both polished and etched surfaces and air-abraded surfaces, were subjected to oxidation procedures recommended by the manufacturers. The specimens were analyzed by x-ray diffraction using CuK alpha radiation, and the peaks were compared to appropriate Joint Committee on Powder Diffraction Standards (JCPDS). RESULTS: The surface preparation procedure had a profound effect on the phases present in the oxide layers. For the specimens that had been polished and etched, CuGa2O4 and beta-Ga2O3 were detected on the 79Pd-10Cu-9Ga-2Au alloy, whereas SnO2 and CuGa2O4 were detected on the 76Pd-10Cu-5.5Ga-6Sn-2Au alloy. The oxide layers on both Pd-Cu-Ga alloys contained Cu2O1 and the oxide layer on the 76Pd-10Cu-5.5Ga-6Sn-2Au alloy may contain beta-Ga2O3. The principal phase in the oxide layers on both Pd-Ga alloys that had been polished and etched was ln2O3, which exhibited extreme preferred orientation. No other phase was detected in the oxide layer on the 85Pd-10Ga-2Au-1Ag-1 ln alloy, whereas beta-Ga2O3 was found in the oxide layer on the 75Pd-6Ga-6Au-6Ag-6.5ln alloy. For the air-abraded specimens, beta-Ga2O2 was not present in the oxide layers on the Pd-Cu-Ga alloys, and beta-Ga2O3 was the major phase in the oxide layers on the Pd-Ga alloys. Palladium oxide(s) in varying amounts were detected for both surface preparations of the Pd-Cu-Ga alloys and for the air-abraded Pd-Ga alloys. Except for the 76Pd-10Cu-5.5Ga-6Sn-2Au alloy, the oxide layer caused minimal change in the lattice parameter of the palladium solid solution compared to that for the as-cast alloy. SIGNIFICANCE: Knowledge of the phases found in the oxide layers on these high-palladium alloys is of fundamental importance for interpreting differences in the adherence of dental porcelain to the metal substrates under static and dynamic conditions, and may provide guidance in the development of new high-palladium alloys with improved metal-ceramic bonding.

Copper↗

Differential scanning calorimetry (DSC) analyses of superelastic and nonsuperelastic nickel-titanium orthodontic wires.

The purpose of this study was to determine the transformation temperatures for the austenitic, martensitic, and rhombohedral (R) structure phases in representative as-received commercial nitinol (NiTi) orthodontic wire alloys, to reconcile discrepancies among recent publications. Specimens were examined by differential scanning calorimetry (DSC) over a temperature range from approximately -170 degrees C to 100 degrees C, with a scanning rate of 10 degrees C per minute. Two different pathways, with the intermediate R structure either absent or present, were observed for the transformation from martensitic to austenitic NiTi, whereas the reverse transformation from austenitic to martensitic NiTi always included the R structure. The enthalpy (delta H) for the transformation from martensite to austenite ranged from 0.3 to 3.5 calories per gram. The lowest delta H value for the nonsuperelastic Nitinol wire is consistent with a largely work-hardened, stable, martensitic microstructure in this product. The DSC results indicate that the transformation processes are broadly similar in superelastic, body-temperature shape-memory, and nonsuperelastic NiTi wires. Differences in bending properties for the NiTi orthodontic wires at room temperature and 37 degrees C are due to the relative proportions of the metallurgical phases in the microstructures.

Alloys↗

Metallurgical structure and microhardness of four new palladium-based alloys.

PURPOSE: This investigation compared the Vickers hardness and microstructures of four recently marketed, palladium-based alloys for metal-ceramic restorations. MATERIALS AND METHODS: Wax patterns simulating copings for maxillary central incisors were invested in a fine-grained, carbon-free, phosphate-bonded investment. Following burnout, the palladium alloys were fused with a gas-oxygen torch, centrifugally cast, and bench-cooled. Representative castings were embedded in transparent metallographic resin and sectioned to yield two mirror-image specimens. The specimens were evaluated in either the as-cast condition or following heat treatment simulating the firing cycles for Vita VMK porcelain. Vickers hardness measurements (n = 50) were made using a 1-kg load, and photomicrographs of polished and etched specimens were obtained with a scanning electron microscope. RESULTS: The measured values of microhardness for the as-cast alloys were in excellent agreement with values reported by the manufacturer. The hardness in the as-cast condition was significantly greater for the Pd-Cu-Ga-In alloy, compared with the other three alloys, which did not contain copper. For the three high-palladium (> or = 75 wt%) alloys, there were small (4%-8%) decreases in hardness following heat treatment, whereas a larger decrease (13%) in hardness occurred for the Pd-Ag-In-Sn alloy after heat treatment. The porcelain firing cycles caused microstructural homogenization for all four alloys, and the relatively thick near-surface oxidation region in the Pd-Cu-Ga-In and Pd-Ag-In-Sn alloys was not observed in the two heat-treated Pd-Ga-Ag-In-Au alloys. CONCLUSIONS: The multiphasic microstructures of these alloys may have some significance for the in vitro and clinical corrosion behavior and the metal-ceramic bond strength. The hardness for the three high-palladium alloys may be controlled by submicroscopic precipitates that remain unaltered by heat treatment. The significantly greater hardness for the Pd-Cu-Ga-In alloy may cause greater difficulty for finishing castings in the dental laboratory compared with the other three alloys studied. The strengthening mechanism for the Pd-Ag-In-Sn alloy has significant temperature dependence, which might be exploited to achieve optimum mechanical properties.

Analysis of Variance↗

X-ray diffraction studies of as-cast high-palladium alloys.

OBJECTIVES: The purpose of this study was to use x-ray diffraction (XRD) to investigate four representative high-palladium alloys in the as-cast condition and obtain new information about the metallurgical phases. METHODS: Two Pd-Cu-Ga alloys and two Pd-Ga alloys were cast into plate-shaped specimens (20 mm x 1.5 mm) which were bench-cooled. Polished and etched specimens were analyzed using two different x-ray diffractometers and CuKa radiation. RESULTS: All four alloys exhibited strong XRD peaks for the face-centered cubic (fcc) palladium solid solution matrix, and variations in the lattice parameter were consistent with alloy compositions. Comparison of the relative peak intensities for the alloys and the pure palladium powder standard indicated that the as-cast microstructures had preferred crystallographic orientation. Because the two Pd-Cu-Ga alloys contained appreciable amounts of near-surface lamellar interdendritic or eutectic constituents, it was possible to determine previously unreported XRD peaks for the Pd2Ga phase in these alloys. Low-intensity peaks in the Pd-Ga alloys were attributed to small amounts of secondary phases observed in the microstructures. SIGNIFICANCE: Knowledge of the metallurgical structures of these high-palladium alloys can be important for interpretation of microstructural observations, mechanical properties, corrosion behavior and clinical performance.

Dental Alloys↗

Physical dimensions, torsional performance, bending properties, and metallurgical characteristics of rotary endodontic instruments. VI. Canal Master drills.

A laboratory study was performed on machine-driven Canal Master drills to determine their physical dimensions, torsional performance, bending properties, and metallurgical characteristics in fracture. Physical dimensions were determined for each of the available sizes (#50 to #100) of Canal Master drills from the manufacturer that distributes these instruments in the United States. Samples were also tested in clockwise torsion using a Maillefer memocouple. Bending properties of cantilever specimens were measured with a Tinius Olsen stiffness tester. Bending fatigue testing was performed on a unique laboratory apparatus. Scanning electron microscope examination confirmed visual observations that the stainless steel Canal Master drills exhibited ductile torsional fracture. This study is part of a continuing investigation to establish standards for all machine-driven rotary endodontic instruments.

Dental High-Speed Equipment↗

Polymerization efficiency of chemically cured and visible light-cured orthodontic adhesives: degree of cure.

The use of light-cured orthodontic adhesives in combination with the new generation of ceramic brackets has become popular from an esthetic standpoint. The purpose of this article was to evaluate the degree of cure (DC) of selected light-cured and chemically cured adhesives bonded to ceramic and stainless steel brackets. The optical properties of eight types of brackets (single-crystal alumina, polycrystalline alumina, polycrystalline allumina with polycarbonate base, and stainless steel) were evaluated by diffuse visible light transmittance spectroscopic analysis. The degree of cure (DC) of a visible light-cured orthodontic adhesive bonded to these brackets under direct (20 seconds through the bracket) and indirect (2 x 10 seconds from the incisal and cervical edges of the bracket) irradiation was measured by micro-MIR FTIR spectroscopy. Brackets bonded to a chemically cured, two-paste orthodontic adhesive were used as a control group. According to the results the single-crystal alumina brackets showed the highest diffuse transmittance values at 468 nm followed by polycrystalline alumina and polycarbonate-base alumina types. Direct irradiation resulted in low DC values that were strongly correlated to the diffuse transmittance measurements at 468 nm (r = 0.73, p < 0.05). Indirect irradiation manifested significantly higher DC values than direct irradiation in the stainless steel bracket group, which yielded values comparable to those found in some indirectly irradiated polycrystalline bracket groups.

Acrylic Resins↗

Residual monomer leaching from chemically cured and visible light-cured orthodontic adhesives.

The objective of this study was to quantify the amount of residual monomer leached from chemically cured and visible light-cured orthodontic adhesives based on Bis-GMA/TEGDMA monomers, when bonded to ceramic and stainless steel brackets. The residual TEGDMA and Bis-GMA monomer concentrations were determined by high performance liquid chromatographic (HPLC) analysis of the extracts after specimen immersion in ethanol/water solution for 15 days at 37 +/- 1 degree C. According to the results the highest monomer concentrations eluted were obtained from the chemically cured adhesive. Direct (through the bracket) irradiation of stainless steel brackets bonded to the visible light-cured adhesive showed high monomer elution as well. A polycarbonate base ceramic bracket manifested significantly greater amount of monomer release compared with ceramic brackets when combined with the visible light-cured adhesive. Indirect (from the incisal and cervical edges of the bracket) irradiation of the visible light-cured adhesive bonded to the stainless steel brackets resulted in lower residual monomer elution compared to that of directly (through the bracket) irradiated metallic brackets. No statistical difference was found between direct or indirect irradiation of the ceramic brackets tested, with respect to monomer elution from the light-cured adhesive.

Adhesives↗

Microbial attachment on orthodontic appliances: I. Wettability and early pellicle formation on bracket materials.

The objectives of this study were to investigate the wettability of orthodontic bracket material surfaces and the composition of salivary films adsorbed onto them after 30 and 60 minutes in vivo exposure. Specimens from stainless steel, fiber-reinforced polycarbonate, and polycrystalline alumina bracket manufacturing raw materials were subjected to (a) contact angle measurements with a homologous series of liquids, (b) micro multiple internal reflection Fourier transform infrared spectroscopy (microMIR FTIR) for the characterization of the molecular composition of the in vivo adsorbed groups, and (c) incident light optical microscopy of the acquired films. The highest critical surface tension was obtained from stainless steel (40.8 +/- 0.4 dynes/cm) followed by polycarbonate (32.8 +/- 1.3 dynes/cm) and alumina (29.0 +/- 0.9 dynes/cm), suggesting a higher potential for increased plaque-retaining capacity for the stainless steel brackets. Accordingly, the total work of adhesion and its polar and nonpolar components were consistent with the surface tension ranking. The nonpolar component of the work of adhesion was higher than its polar counterpart for all materials tested, implying a possible higher attachment prevalence for those microorganisms using dispersive forces, such as van der Waals forces, as the predominant attachment mechanism to surfaces. Qualitative and quantitative variations were observed in the adsorbed films after 30 and 60 minutes intraoral exposure that may reflect the influence of the surface properties of these substrates on the structure of the pellicle formed in vivo.

Adhesiveness↗

A three-dimensional finite element stress analysis of angled abutments for an implant placed in the anterior maxilla.

PURPOSE: A three-dimensional mathematical model of the maxilla was developed that was used to analyze the stresses and strains produced by an abutment system capable of three abutment angulations. MATERIALS AND METHODS: Computed tomography was used to derive the geometry and density values used for the maxillary model. A 3.8 x 10-mm cylindrical implant was embedded in the right central incisor position at a 35 degrees angle to the horizontal plane and parallel to the angulation of the bone site. All geometric and elastic properties for the fixture and the surrounding bone were included in the model. A simulated occlusal load of 178 N was applied along the long axis of 0 degrees, 15 degrees, and 20 degrees abutments. The mathematical models were solved by the Cray Y/MP Ohio Supercomputer (Cray, Eagan, MN) using the ABAQUS software program (Hibbitt, Karlsson, and Sorenson, Providence, RI). RESULTS: Numerical and graphic results were generated for the maximum (tensile) and minimum (compressive) stresses and strains. Principal stresses occurred predominantly in the cortical bone layers, whereas strains occurred mostly in the cancellous bone. CONCLUSIONS: In general, there was an increase in the magnitude of stress and strain as the abutment angulation increased. Reported stresses and strains for all three angles were within or slightly above the physiological zone derived from animal studies. A need to investigate the response of human bone to stress and strain was indicated.

Alveolar Process↗

Performance of engine-driven rotary endodontic instruments with a superimposed bending deflection: V. Gates Glidden and Peeso drills.

A laboratory study was performed on Gates Glidden and Peeso drills to determine the incidence of shaft fracture when a bending deflection was superimposed on the rotating drills. Samples of sizes #1 to #6 stainless steel Gates Glidden drills, sizes #1 to #6 stainless steel and carbon steel-type P Peeso drills, and sizes #009 to #023 carbon steel-type B-1 Peeso drills from each of two manufacturers were evaluated with a unique apparatus that applied a 2-mm bending deflection while rotating the instruments. The apparatus did not restrict movement of the bur head during rotation. The test drills were rotated at 2500, 4000, and 7000 revolutions per minute, and the number of revolutions at failure was recorded. Scanning electron microscopic observations established that the stainless steel Gates Glidden and Peeso drills failed by ductile fracture, whereas the carbon steel Peeso drills failed by brittle fracture. Instrument fracture was always near the handpiece shank with this test, and the length of the fractured drills was measured from the working tip. It is recommended that this additional test be adopted to determine fatigue properties of engine-driven rotary endodontic instruments in establishing international performance standards.

Dental High-Speed Equipment↗

Surface characterization of ceramic brackets: a multitechnique approach.

The purpose of this study was to investigate the microstructure and bonding mechanisms for four types of ceramic brackets by using information from several methods. Two of the bracket types provided exclusively micromechanical retention as a bonding mechanism, with the use of microspheres or microcrystals to achieve a rough structure for the bracket base. A silane layer that provided chemical adhesion was found to cover the bases of the two other types of brackets; one type also used central regions of increased roughness to provide additional micromechanical retention. Polarized-light optical microscopy showed that the silane layer was not continuous. Small area x-ray photoelectron spectroscopy analysis (SAXPS) of the silane layer was consistent with the presence of gamma-methacryloxypropyl trimethoxysilane. The study of the ceramic bracket bases revealed a wide variety in composition, structure, morphologic condition, and coating treatment that implies different bonding mechanisms to orthodontic adhesives.

Aluminum Oxide↗