Entrainment and interruption of atrial flutter with atrial pacing: studies in man following open heart surgery.

To examine the question of why the pacing rate and duration of atrial pacing are crucial factors in the successful interruption of atrial flutter, studies were performed on 30 patients in the period following open heart surgery. In each patient the diagnosis of atrial flutter was made using a pair of wire electrodes placed on the right atrial epicardium at the time of operation and brought out through the anterior chest wall. The same electrodes were used for atrial pacing. Pacing faster than the spontaneous rate of the atrial flutter which failed to interrupt the atrial flutter was associated with transient entrainment of the atrial flutter up to the atrial pacing rate. Atrial flutter was interrupted successfully when the atria were paced at a rate which was too fast for the atrial flutter to follow. This was heralded by the conversion of previously negative flutter waves to positive atrial complexes in ECG lead II. When pacing the atria at a constant rate, 2-22 seconds with a mean of 10 seconds were required to interrupt the atrial flutter.

Adult↗

Continuous rapid atrial pacing to control recurrent or sustained supraventricular tachycardias following open heart surgery.

A technique is described to control recurrent or sustained supraventricular tachycardia associated with rapid ventricular rates following open heart surgery. The technique utilizes a pair of temporarily implanted atrial epicardial wire electrodes to pace the heart. In one group of patients with recurrent atrial flutter and 2:1 A-V conduction, continuous rapid atrial pacing at 450 beats/min produced and sustained atrial fibrillation. The ventricular response rate immediately slowed when compared to that during atrial flutter, and if further slowing was required, it was easily accomplished by the administration of digitalis. Another group of patients with different arrhythmias (recurrent paroxysmal atrial tachycardia, sustained ectopic atrial tachycardia, or sinus rhythm with premature atrial beats which precipitated runs of atrial fibrillation) was treated with continuous rapid atrial pacing to produce 2:1 A-V block. In all instances, the continuous rapid atrial pacing suppressed the supraventricular tachycardia and maintained the ventricular response rate in a therapeutically desirable range. It was demonstrated that the technique is safe, effective, and reliable.

Adult↗

P waves during ectopic atrial rhythms in man: a study utilizing atrial pacing with fixed electrodes.

Threshold bipolar pacing was performed from one of 12 selected atrial sites with temporary implanted electrodes in 69 patients following open-heart surgery in order to study P wave polarity and morphology and the P-R interval during paced ectopic atrial rhythms. A negative P wave was recorded in lead I only with pacing the left atrium and only when pacing near the left pulmonary veins. A positive bifid P wave in V1 was recorded only with left atrial pacing and only when pacing was near the inferior pulmonary veins and coronary sinus. P wave polarity and morphology were otherwise of no use in localization of the origin of the impulse in these studies. The pacing stimulus to P wave interval was found to vary between 10 and 54 msec, making the duration of the P-R interval an unreliable indicator of the site of origin of the paced impulse. Although the relation of these paced rhythms to spontaneously occurring ectopic rhythms is unclear, the previously published criteria for localizing ectopic atrial rhythms are again demonstrated to be unreliable. P wave polarity and morphology and the P-R interval are of limited value in ascertaining the origin of ectopic atrial rhythms in man.

Adult↗