PubMed Health⌕ Search

Biomedical subjects

W A Mandarino

Publications and source records attributed to W A Mandarino.

At least 19 recordsLinked to original sources

Color-coded tissue Doppler assessment of the effects of acute ischemia on regional left ventricular function: comparison with sonomicrometry.

Echocardiographic assessment of regional left ventricular (LV) function usually consists of subjective visual inspection of endocardial movement and wall thickening. Color-coded tissue Doppler (TD) is a potential means to quantify regional LV function more objectively. Accordingly, in this study, color-coded TD was used to assess the regional effects of acute ischemia in an open-chest canine model of coronary occlusion, with implanted sonomicrometry length crystals as a standard of reference. Eight dogs were studied during baseline conditions and during left anterior descending coronary artery occlusion. Midventricular short-axis images were used to guide the color TD M-mode cursor through circumflex (septal) and left anterior descending (anterolateral) perfusion zones. Off-line conversion of endocardial time-velocity maps was performed. Peak systolic endocardial velocity by TD decreased from 4.4 +/- 1.4 cm/s to 1.8 +/- 1.5 cm/s with coronary occlusion (P < .05 versus baseline). Similar significant decreases in calculated systolic velocity by sonomicrometry occurred with ischemia from 11.1 +/- 3.8 mm/s to 8.2 +/- 1.2 mm/s (P < .05 versus baseline). Peak systolic velocity by TD was inversely correlated with end-systolic length by sonomicrometry as a measure of regional function (r = -0.77, P < .001). Time to peak systolic velocity increased with ischemia from 154 +/- 60 ms to 286 +/- 67 ms by TD and 200 +/- 60 ms to 320 +/- 30 ms by sonomicrometry (P < .05 versus baseline). The delay in time to peak systolic velocity by TD and sonomicrometry were correlated (r = 0.75, P < .001). In conclusion, color-coded TD echocardiography has the potential to quantify regional LV function during coronary ischemia.

Animals↗

Assessment of left internal mammary artery graft patency and flow reserve after minimally invasive direct coronary artery bypass.

Despite its merits, minimally invasive direct coronary artery bypass surgery (MIDCAB) has been criticized for variable left internal mammary artery (LIMA) graft patency rates, prompting the frequent use of postoperative LIMA angiography. Noninvasive transthoracic Doppler interrogation of LIMA grafts has recently been shown to have utility for assessing patency and flow reserve after conventional bypass surgery, but data after MIDCAB has been limited. The objective of this study was to assess LIMA graft anatomy and physiology in 54 patients after MIDCAB using angiography and noninvasive LIMA Doppler imaging. The right internal mammary artery (RIMA) was studied as a control. LIMA flow reserve in response to adenosine was evaluated in a subgroup of 18 randomly chosen patients with patent grafts. LIMA angiographic patency was 93%. Forty-four patients (81%) had obtainable LIMA Doppler data. Patent grafts had a diastolic dominant flow pattern with a peak diastolic/systolic velocity ratio of 1.3 +/- 0.6 and a percent diastolic time-velocity integral (TVI) of 70 +/- 11%. These data were significantly different than the RIMA control values of 0.2 +/- 0.1 and 30 +/- 10%, respectively (p <0.05). Occluded grafts had absent flow or a systolic dominant pattern. Adenosine-induced increases in LIMA peak diastolic velocity from 48 +/- 20 to 105 +/-28 cm/s (p <0.05 vs baseline) and diastolic TVI from 21 +/- 10 to 37 +/- 19 cm (p <0.05 vs baseline), yielding adenosine/baseline ratios of 2.4 +/- 0.9 and 2.0 +/- 0.7, respectively, which was consistent with normal flow reserve. The diastolic flow velocity reserve response was inversely related to baseline diastolic flow (r = -0.69). In conclusion, MIDCAB can be associated with a high rate of LIMA potency and favorable physiologic Doppler flow patterns. Correlation of these findings to long-term patient outcome after MIDCAB is warranted.

Adenosine↗

Evaluation of the potential role of color-coded tissue Doppler echocardiography in the detection of allograft rejection in heart transplant recipients.

BACKGROUND: Color-coded tissue Doppler (TD) echocardiography can noninvasively quantify alterations in left ventricular (LV) systolic and diastolic function. The objective of this study was to test the hypothesis that TD may play a role in the detection of LV dysfunction associated with allograft rejection in heart transplant recipients. METHODS AND RESULTS: Seventy-eight consecutive transplant recipients underwent 89 TD studies of posterior wall myocardial velocity gradient and mitral annular velocity within 1 hour of endomyocardial biopsy. Color TD echocardiographic images were digitized for semiautomated computer analysis. Histologic analysis revealed no significant rejection in 75 biopsies and significant rejection in 14. TD posterior wall peak systolic and diastolic velocity gradients were reduced significantly with rejection: 3.9 +/- 2.0 s(-1) versus 2.6 +/- 0.9 s(-1) and 5.4 +/- 2. 4 s(-1) versus 3.5 +/- 1.6 s(-1), respectively (P <.05 vs the nonrejecting group). Peak systolic and diastolic mitral annular velocities by TD were also reduced with rejection: 63 +/- 14 mm/s versus 49 +/- 12.4 mm/s and 90 +/- 23 mm/s versus 60 +/- 21 mm/s, respectively (P <.001 vs the nonrejecting group). A TD peak-to-peak mitral annular velocity >135 mm/s had 93% sensitivity, 71% specificity, and 98% negative predictive value for detecting rejection. Although TD was unable to discriminate between rejection and other causes of low velocity values, high TD velocity values were supportive of excluding rejection. CONCLUSIONS: These data suggest that color-coded TD may play a potential role as a screening test to exclude rejection in heart transplant recipients. Although this method has the potential to decrease the number of biopsies, further testing in a larger series of transplant recipients with rejection is warranted.

Biopsy↗

Determinants of aortic pressure variation during positive-pressure ventilation in man.

STUDY OBJECTIVES: To define the relation between systolic arterial pressure (SAP) changes during ventilation and left ventricular (LV) performance in humans. DESIGN: Prospective repeat-measures series. SETTING: University of Pittsburgh Medical Center Operating Room. PATIENTS: Fifteen anesthetized cardiac surgery patients before and after cardiopulmonary bypass when the mediastinum was either closed or open. INTERVENTIONS: Positive-pressure ventilation. MEASUREMENTS AND RESULTS: SAP and LV midaxis cross-sectional areas were measured during apnea and then were measured for three consecutive breaths. SAP increased during inspiration, this being the greatest during closed chest conditions (p < 0.05). Changes in SAP could not be correlated with changes in either LV end-diastolic areas (EDAs), end-systolic areas, or stroke areas (SAs). If SAP decreased relative to apnea, the decrease occurred during expiration and was often associated with increasing LV EDAs and SAs. SAP often decreased after a positive-pressure breath, but the decrease was unrelated to SA deficits during the breath. Increases in SAP were in phase with increases in airway pressure, whereas decreases in SAP, if present, followed inspiration. No consistent relation between SAP variation and LV area could be identified. CONCLUSIONS: In this patient group, changes in SAP reflect changes in airway pressure and (by inference) intrathoracic pressure (as in a Valsalva maneuver) better than they reflect concomitant changes in LV hemodynamics.

Aorta↗

Assessment of left ventricular contractile state by preload-adjusted maximal power using echocardiographic automated border detection.

OBJECTIVES: We sought to assess the ability of preload-adjusted maximal power measured by echocardiographic automated border detection (ABD) to quantify left ventricular (LV) contractility by determining the effects of alterations in preload, afterload and contractile state. BACKGROUND: Preload-adjusted maximal power can reflect LV contractile state relatively independent of changes in loading conditions. METHODS: Eight anesthetized dogs had placement of aortic electromagnetic flow probes, LV and arterial pressure catheters and inferior vena caval (IVC) occluders; four had placement of thoracic aortic balloon occluders. Echocardiographic ABD measures of cross-sectional area were used as a surrogate for LV volume, and flow was estimated as the first derivative of area with respect to time. Power was calculated as the product of flow and pressure. RESULTS: Preload independence during vena caval occlusions was achieved by preload adjustment (1/[end-diastolic area]3/2). Afterload independence was demonstrated by preload-adjusted maximal power being unaffected by acute increases in LV systolic pressure induced by aortic occlusion. ABD preload-adjusted maximal power reflected changes in contractile state: increasing with dobutamine infusion from 36+/-14 to 70+/-15 mW/cm4 (p < 0.05 vs. control) and decreasing with propranolol infusion from 35+/-13 to 17+/-7 mW/cm4 (p < 0.05 vs. control). These changes were significantly correlated with calculations of preload-adjusted maximal power using aortic flow (r = 0.90, SEE 10.5 mW/cm4) and load-independent measures of end-systolic elastance from pressure-area loops (r = 0.90, SEE 10.6 mW/cm4). Calculations of normalized preload-adjusted maximal power using arterial pressure were also closely correlated with similar calculations using LV pressure (r = 0.99, SEE 3%). CONCLUSIONS: Preload-adjusted maximal power using echocardiographic ABD can predict LV contractile state relatively independent of loading conditions and has potential for clinical application.

Animals↗

Heterogeneous immediate effects of partial left ventriculectomy on cardiac performance.

BACKGROUND: Partial left ventriculectomy (PLV) is a novel surgical treatment for severe heart failure consisting of resection of a large wedge of myocardium to reduce wall stress and restore the normal mass-volume ratio. Although ejection fraction (EF) has been shown to improve after PLV, few other physiological data describing its immediate effects on left ventricular (LV) performance are available. METHODS AND RESULTS: Eight patients, 58+/-5 years old, with severe clinical heart failure and EF of 12+/-3% were studied before and immediately after PLV. LV performance was assessed by the predominantly load-insensitive measures of pressure-area relations with high-fidelity pressure catheters and transesophageal automated echocardiographic measures of cross-sectional area as a surrogate for volume. LV end-diastolic volume decreased from 200+/-60 to 89+/-17 mL, EF increased from 12+/-3% to 41+/-8%, and right ventricular (RV) fractional area change increased from 24+/-12% to 37+/-16% (all P<.05 versus before). Changes in pressure-area relations were variable: end-systolic elastance, 6.5+/-3.4 to 4.3+/-2.5 mm Hg/cm2 and preload recruitable stroke work, 33+/-16 to 34+/-19 mm Hg (P=NS versus before). End-diastolic stiffness increased from 0.13+/-0.06 to 0.19+/-0.07 mm Hg/cm2 (P<.05 versus before). Improvement in LV performance was inversely correlated with semiquantitative histological assessment of myocardial fibrosis and positively correlated with nuclear enlargement and hyperchromasia, indicative of myocyte hypertrophy. No long-term follow-up data were available. CONCLUSIONS: PLV resulted in reductions in LV volumes, increases in EF and RV ejection, but increases in LV stiffness. Estimates of LV performance revealed variable results associated with the degree of myocardial fibrosis. Further study of these effects in relation to patient outcome is warranted.

Aged↗

Quantification of the myocardial response to low-dose dobutamine using tissue Doppler echocardiographic measures of velocity and velocity gradient.

Low-dose dobutamine echocardiography has been clinically useful in myocardial viability studies, although routine visual assessment of wall motion is subjective. The objective was to quantify the incremental myocardial response to low-dose dobutamine infusion using a new semiautomated tissue Doppler (TD) analysis system and to compare these data with routine echocardiographic measures in the same subjects. Twelve subjects had TD and routine echocardiographic studies at baseline and during 10-minute stages of dobutamine infusion at 1, 2, 3, and 5 microg/kg/min. Color TD video data were converted to a digital velocity matrix (4.5 velocity data points/mm at 500 Hz) for analysis of mitral annular velocity, endocardial velocity, and velocity gradient at each stage. Posterior wall percent thickening and ejection fraction were calculated from the routine images. Mitral annular peak systolic velocity significantly increased with only 1 microg/kg/min of dobutamine from 69 +/- 9 to 77 +/- 7 mm/s (p <0.05 vs baseline), and further incremental increases occurred with each subsequent dose. Anteroseptal and posterior wall peak endocardial velocity increased with 2 microg/kg/min of dobutamine from 33 +/- 7 to 46 +/- 15 mm/s and 50 +/- 9 to 61 +/- 10 mm/s, respectively (p <0.01 vs baseline) and further increased with 5 microg/kg/min (p <0.0001 vs 3 microg/kg/min). Posterior wall peak systolic gradient also increased with 2 microg/kg/min of dobutamine from 3.1 +/- 0.6 to 5.4 +/- 1.6 s(-1) (p <0.05 vs baseline). Routine measures of percent wall thickening or ejection fraction did not detect increases until the 3 microg/kg/min dose. TD can detect subtle alterations in contractility induced by low-dose dobutamine and has the potential to quantify regional ventricular function objectively.

Adrenergic beta-Agonists↗

Quantitative assessment of alterations in regional left ventricular contractility with color-coded tissue Doppler echocardiography. Comparison with sonomicrometry and pressure-volume relations.

BACKGROUND: Tissue Doppler imaging (TDI) is a novel method of color-coding myocardial velocity on-line. The objective of the present study was to evaluate endocardial velocity with TDI as a method of objectively quantifying alterations in regional contractility over a wide range induced by inotropic modulation. METHODS AND RESULTS: Myocardial length crystals were used to simultaneously assess regional left ventricular (LV) function, and high-fidelity pressure and conductance catheters were used to assess global LV contractility by pressure-volume relations in nine open-chest dogs. Mid-LV M-mode and two-dimensional color TDI images were recorded during control and inotropic modulation stages with dobutamine and esmolol. Predicted significant increases in TDI indices occurred with dobutamine: peak systolic velocity of 4.41 +/- 1.07 to 6.67 +/- 1.07 cm/s*, systolic time-velocity integral (TVI) of 0.43 +/- 0.12 to 0.62 +/- 0.10 cm*, and diastolic TVI of 0.49 +/- 0.11 to 0.71 +/- 0.17 cm*. Opposing significant decreases occurred with esmolol: peak systolic velocity of 4.46 +/- 0.94 to 2.31 +/- 0.81 cm/s*, systolic TVI of 0.47 +/- 0.12 to 0.19 +/- 0.11 cm*, and diastolic TVI of 0.55 +/- 0.11 to 0.33 +/- 0.11 cm* (*all P < .001 versus control). Changes in TDI peak systolic velocity were correlated with changes in fractional shortening (r = .88) and shortening velocity (r = .87) by sonomicrometry. Changes in TDI peak velocity from multiple mid-LV sites also correlated significantly with maximal elastance (r = .85 +/- .04) from pressure-volume relations. CONCLUSIONS: TDI measures reflect directional and incremental alterations in regional and global LV contractility and have the potential to quantify regional LV function.

Adrenergic beta-Antagonists↗

Right ventricular performance and left ventricular assist device filling.

BACKGROUND: Right ventricular (RV) function is believed to be an important determinant of left ventricular assist device (LVAD) filling. This study was designed to demonstrate this relation in patients. METHODS: To demonstrate the interaction between RV ejection and LVAD filling, 10 patients (mean age, 49 +/- 13 years) supported with an LVAD were studied. Right ventricular pressure-area loops from cross-sectional area using transesophageal echocardiographic automated border detection and high-fidelity RV pressure were recorded simultaneously with LVAD volume during intraoperative inferior vena cava occlusion. Beat-by-beat RV ejection phase indices were calculated: stroke area, peak ejection rate, and stroke work. The LVAD filling rate was calculated as the first derivative of the volume, and the peak filling rate and the mean filling rate during RV systole were determined for each cardiac cycle. RESULTS: Right ventricular stroke area, peak ejection rate, and stroke work were closely correlated with LVAD peak filling rate (r = 0.87 +/- 0.09, r = 0.83 +/- 0.09, and r = 0.85 +/- 0.10, respectively). Also, baseline LVAD mean filling rate correlated with RV stroke work (r = 0.77) and LVAD peak filling rate with RV peak ejection rate for the group (r = 0.75). CONCLUSIONS: These correlations demonstrate predictable associations of RV ejection with LVAD filling.

Heart Failure↗

Left ventricular performance assessed by echocardiographic automated border detection and arterial pressure.

Automated echocardiographic measures of left ventricular (LV) cavity area are closely correlated with changes in volume and can be coupled with LV pressure (PLV) to construct pressure-area loops in real time. The objective was to rapidly estimate LV contractility from end-systolic relationships of cavity area (as a surrogate for LV volume) and central arterial pressure (Pa) (as a surrogate for PLV) in a canine model using automated algorithms. In eight anesthetized mongrel dogs, we simultaneously measured PLV, LV area, and Pa (fluid-filled catheter). End-systolic pressure-area relationships in terms of pressure-area elastance (E'es)] from pressure-area loops during inferior vena caval occlusions were determined during basal conditions (control), dobutamine infusion (5-10 micrograms.mg-1.min-1), and after bolus propranolol (2 mg/kg) with both PLV and Pa by semiautomated and automated iterative regression methods. E'es increased during dobutamine infusion and decreased after propranolol infusion in all animals and with all iterative methods. Estimates of Ees from Pa were closely correlated with E'es from PLV by both the semiautomated and automated methods (r = 0.93; P < 0.01). The relationship between E'es obtained from Pn for the two methods was also closely correlated. Although the automated methods displayed larger differences from the semiautomated iterative technique by Bland-Altman analysis, the change in E'es with all techniques during dobutamine infusion and after propranolol infusion was of similar magnitude and direction among the three techniques. Greater variability with the dobutamine runs was partially due to abnormally conducted ventricular beats that minimized the number of consecutive beats that could be used for these analyses. We conclude that on-line Pa recordings from fluid-filled catheters can be used with echocardiographic automated border detection to rapidly calculate E'es as a means to estimate LV contractility.

Algorithms↗

Right ventricular performance and contractile reserve in patients with severe heart failure. Assessment by pressure-area relations and association with outcome.

BACKGROUND: Right ventricular (RV) performance appears to be important in patients with severe heart failure. Although clinical assessments of RV function previously have been limited to load-dependent ejection phase indices, a new method has been developed using the relatively load-insensitive concepts of pressure-volume relations with automated echocardiographic measures of RV cross-sectional area as a surrogate for volume. METHODS AND RESULTS: Sixteen patients with New York Heart Association functional class IV heart failure and group mean left ventricular ejection fraction of 20 +/- 5% were studied. RV pressure-area loops were recorded on-line from echocardiographic measures of RV area and high-fidelity pressure during transient inferior, vena caval balloon occlusions. RV contractile reserve was assessed as its functional response to an increase in dobutamine from 5.7 +/- 4.1 to 13.1 +/- 4.7 micrograms/kg per minute. Complete data sets were available in 13 patients. Group mean RV end-systolic elastance (E'es) and maximal elastance (E'max) increased with augmented dobutamine infusion (2.9 +/- 1.5 to 5.5 +/- 3.3 mm Hg/cm2 and 3.3 +/- 1.6 to 6.4 +/- 3.9 mm Hg/cm2, respectively; P < .01 versus baseline), although individual responses were variable. During a 30-day follow-up, 9 patients remained unstable, requiring continuous intravenous inotropic therapy; 6 of these had profound deterioration requiring mechanical circulatory support. The remaining 4 patients had a comparatively good short-term outcome with clinical stability. A 100% increase in RV E'es or E'max was associated with a good short-term outcome (P < .05). CONCLUSIONS: RV performance can be assessed by pressure-area relations in patients with heart failure. RV contractile reserve in response to increases in dobutamine was associated with a good short-term outcome and may be of prognostic value in patients with severe heart failure.

Adult↗

Color-coded measures of myocardial velocity throughout the cardiac cycle by tissue Doppler imaging to quantify regional left ventricular function.

TDI is a new echocardiographic technique that calculates and displays color-coded myocardial velocity on-line. To determine the feasibility of endocardial velocity throughout the cardiac cycle as a means to quantify regional function, 20 normal subjects aged 30 +/- 5 years and 12 patients with heart disease aged 62 +/- 17 years were studied with a prototype TDI system. TDI M-mode images were acquired by using a multicolored velocity map (display range, -30 to 30 mm/sec; temporal resolution, 90 Hz). Color-coded velocity data were then converted to numeric values off-line at 50 msec intervals. Posterior wall velocities throughout the cardiac cycle by TDI were closely correlated with velocity calculations from the first derivative of routine digitized M-mode tracings (group mean r = 0.88 +/- 0.03, SEE = 7.0 +/- 1.1 mm/sec). Anteroseptal TDI color-coded systolic velocity occurred 164 +/- 84 msec from the onset of the electrocardiographic QRS compared with 203 +/- 33 msec in the posterior wall (P < 0.05) in normal subjects, consistent with normal electrical activation. Significant differences in systolic and diastolic posterior wall TDI velocity data were observed in patients with hypokinetic or akinetic segments assessed by independent routine study when compared with normal controls. Calculated systolic and early diastolic posterior wall TDI indexes correlated significantly with percentage of wall thickening. Of abnormal anteroseptal segments, TDI systolic time velocity integrals were significantly different than normal and correlated with percentage of wall thickening. TDI has potential to quantitatively assess regional left ventricular function.

Adult↗

Left ventricular pressure-volume relations with transesophageal echocardiographic automated border detection: comparison with conductance-catheter technique.

Pressure-volume relations are important means used to assess left ventricular (LV) contractility; however, on-line volume acquisition has been limited to the invasive conductance catheter. The objective was to compare simultaneous measures of LV volume by transesophageal echocardiographic automated border detection (ABD) and conductance catheter and their respective pressure-volume relations during steady state and alterations in preload and contractility. Seven dogs had placement of high-fidelity pressure and conductance catheters, a vena caval balloon occluder, and a transesophageal probe. An automated Simpson's rule volume algorithm was used from the transverse four-chamber view. Inotropic modulation was induced with dobutamine in four dogs and propranolol in three. Relative changes in ABD volume were linearly related to conductance volume at steady state with group mean r = 0.93 +/- 0.03, standard error of estimate (SEE) = 10 +/- 2%. Changes in end-diastolic volume, end-systolic volume, and stroke work with caval occlusion were also significantly correlated:r = 0.93 =/- 0.04, SEE = 3.6 ml; r = 0.89 +/- 0.04, SEE = 3.8 +/- 1.9 ml; and r = 0.86 +/- 0.05, SEE = 40 +/- 21 mJ, respectively. The overall bias was for absolute ABD volume to be less. End-systolic and maximal elastance values by ABD were significantly higher than by the conductance method; baseline group average 4.97 +/- 0.92 mm Hg/ml versus 2.70 +/- 1.15 mm Hg/ml and 6.63 +/- 1.66 mm Hg/ml versus 3.20 +/- 1.37 mm Hg/ml (p<0.05), respectively. However, the direction and relative magnitude of changes in elastance with inotropic modulation were similar.

Analysis of Variance↗

Potential influence of intraluminal thrombus on abdominal aortic aneurysm as assessed by a new non-invasive method.

Intraluminal thrombus may play a role in abdominal aortic aneurysm pathogenesis and rupture. The purpose of this work was to demonstrate the feasibility of a new non-invasive method for the determination of the biomechanical features of the aortic wall and luminal boundary in abdominal aortic aneurysm containing intraluminal thrombus. Automated ultrasonographic measures of infrarenal aortic cross-sectional area (A) were obtained on-line along with non-invasive arterial pressure (p) from eight patients of mean (s.e.m.) age 74(3) years, with abdominal aortic aneurysm (mean dimensions 5.9(0.4) x 5.3(0.5) cm) containing intraluminal thrombus. Luminal boundary and abdominal aortic aneurysm wall were scanned separately. Compliance (C) was computed as C = (Amax - Amin)/[Amax(Pmax - Pmin)], where 'max and 'min' represent maximum and minimum values, respectively. Mean compliance was lower for the abdominal aortic aneurysm wall alone than for the luminal surface enclosed by intraluminal thrombus: 4.0(0.9) x 10(-4)/mmHg versus 9.8(1.7) x 10(-4)/mmHg (P < 0.01). Intraluminal thrombus area was nearly constant over the cardiac cycle, indicating that the thrombus is virtually incompressible. This noninvasive method to assess biomechanical features of abdominal aortic aneurysm has potential to further the understanding of the influences of intraluminal thrombus on aneurysm disease.

Aged↗

Long-term animal survival with an implantable axial flow pump as a left ventricular assist device.

We are developing an axial flow blood pump with Nimbus Inc. (AxiPump). For in vivo evaluation the AxiPump has been used as a left ventricular assist device with a left ventricular and descending aorta cannulation and implantation in a small pocket on the left lateral abdominal wall just posterior to the costal margin. Electrical and flow probe leads exit the body transcutaneously. A purge line that delivers the purge fluid for lubrication of the seal between the rotor and stator bodies in the purge fluid bearing system is tunneled with the other leads. Following acute animal studies, 3 animals have been supported for over 1 month with this AxiPump system. All laboratory results were within normal limits except during a recovery period from surgical damage. Hemolysis was not a serious problem. In the first case, the purge system failed at 28 days, and in the second and third cases, the nonpurge bearing system worked well for 57 and 52 days, respectively. Bearings are still under development in this kind of pump. However, this success encourages us to improve the AxiPump as a long-term assist device.

Animals↗

Controller for an axial flow blood pump.

A rotary blood pump inherently provides only one noninvasive "observable" parameter (motor current) and allows for only one "controllable" parameter (pump speed.) To maintain the systemic circulation properly, the pump seed must be controlled to sustain appropriate outlet flows and perfusion pressure while preventing pulmonary damage caused by extremes in preload. Steady-state data were collected at repeated intervals during chronic trials of the Nimbus AxiPump (Nimbus, Inc., Rancho Cordova, California, U.S.A.) in sheep (n = 7) and calves (n = 12). For each data set, the pump speed was increased at increments of 500 rpm until left ventricular and left atrial emptying was observed by left atrial pressure diminishing to zero. The effect of decreasing preload was evaluated perioperatively by inferior vena cava occlusion at a constant pump speed. Fourier analysis established a relationship between changes in the pump preload and the power spectra of the pump current waveform. Based on these results, a control method was devised to avoid ventricular collapse and maintain the preload within a physiologic range. The objective of this controller is the minimization of the second and third harmonic of the periodic current waveform. This method is intended to provide a noninvasive regulation of the pump by eliminating the need for extraneous transducers.

Animals↗

Changes in electrocardiographic morphology reflect instantaneous changes in left ventricular volume and output in cardiac surgery patients.

We examined the relation between changes in R-to-T wave amplitude ratios (R:T) and left ventricular (LV) performance as cardiac output was rapidly varied by inferior vena caval occlusion in 6 subjects prior to cardiopulmonary bypass. To assess the influence of contractility, paired studies before and after bypass were performed in 4 subjects. Stroke volume and cardiac output were assessed by aortic flow probe, and transesophageal echocardiographic LV area measures using the automated border-detection method were used to give LV stroke area, stroke force, maximal LV area, fractional area change, end-systolic elastance, and preload recruitable stroke force. Data were collected on computer and analyzed by linear regression. Significant changes in R:T and measured LV variables during the inferior vena caval occlusion were stroke volume (r = 0.81), LV stroke area (r = 0.77), LV stroke force (r = 0.81), maximal LV area (r = 0.78), and cardiac output (r = 0.80). However, R:T varied inconsistently in relation to fractional area change. After cardiopulmonary bypass, the linear relation between R:T with LV stroke force, LV stroke volume, and maximal LV area persisted, but at a lesser slope. Although absolute pre-inferior vena caval occlusion R:T did not correlate with end-systolic elastance or preload recruitable stroke force, the change in the slope of these linear relations correlated well with the change in end-systolic elastance after surgery (r = 0.92). Instantaneous changes in electrocardiographic morphology reflect changes in LV preload-dependent variables, whereas long-term changes in electrocardiographic morphology may also reflect changes in contractile state.

Aged↗

Automated echocardiographic measures of right ventricular area as an index of volume and end-systolic pressure-area relations to assess right ventricular function.

BACKGROUND: On-line determination of right ventricular (RV) volume to assess its function is clinically difficult. Echocardiographic automated border detection measures of left ventricular (LV) cavity area have been shown to reflect changes in volume, and pressure-area relations have been used to estimate LV contractility. The potential for RV cavity area to estimate changes in volume and to assess RV function, however, has not been evaluated. Accordingly, the objective of this study was to determine the relation between echocardiographic automated border-detected RV cross-sectional area and true volume and to assess the potential for end-systolic pressure-area relations to estimate RV function in an isovolumically contracting isolated canine heart preparation. METHODS AND RESULTS: Eight excised dog hearts with both right and left intraventricular balloons were perfused in an ex vivo apparatus in which both ventricular volumes were controlled independently. RV area data from the level of the left midventricular short-axis plane and pressure data were recorded on a computer through a customized hardware and software interface with the ultrasound system. RV volumes were varied from 9.4 +/- 3.9 to 43.8 +/- 6.9 mL at each of three different LV volume ranges (low range, 12.5 +/- 3.8 mL; medium range, 23.9 +/- 5.6 mL; and high range, 37.5 +/- 5.4 mL). The variation of RV area during isovolumic contraction, which we called deformational area change, was considerable (1.49 +/- 0.68 cm2 mean +/- SD) but did not change significantly with changing RV and LV volumes. Linear regression analysis correlated the maximum, minimum, and mean automated border-detected RV area during isovolumic contraction with absolute volume. A predominantly linear relation was observed, with the group mean r = .98 (y = 0.16x + 0.97; SEE = 0.21 cm2). The effect of LV volume on RV area-volume relation was a significant parallel downward shift (P < .05) by increases in LV volume. End-systolic pressure-area and pressure-volume relations using simultaneously RV pressure were both highly linear and covaried with changing LV volume. CONCLUSIONS: Echocardiographic automated border-detected RV area reflects changes in RV volume under a constant LV volume, and the derived end-systolic pressure-area relation has potential for on-line assessment of RV function.

Animals↗