Patient injury from flash-sterilized instruments.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to W A Rutala.
Explore the source record for details and available documents.
Patients hospitalized in ICUs are 5 to 10 times more likely to acquire nosocomial infections than other hospital patients. The frequency of infections at different anatomic sites and the risk of infection vary by the type of ICU, and the frequency of specific pathogens varies by infection site. Contributing to the seriousness of nosocomial infections, especially in ICUs, is the increasing incidence of infections caused by antibiotic-resistant pathogens. Prevention and control strategies have focused on methicillin-resistant Staphylococcus aureus, vancomycin-resistant Enterococcus, and extended-spectrum beta-lactamase-producing Gram-negative bacilli, among others. An effective infection control program includes a surveillance system, proper handwashing, appropriate patient isolation, prompt evaluation and intervention when an outbreak occurs, adherence to standard guidelines on disinfection and sterilization, and an occupational health program for health-care providers. Studies have shown that patients infected with resistant strains of bacteria are more likely than control patients to have received prior antimicrobials, and hospital areas that have the highest prevalence of resistance also have the highest rates of antibiotic use. For these reasons, programs to prevent or control the development of resistant organisms often focus on the overuse or inappropriate use of antibiotics, for example, by restriction of widely used broad-spectrum antibiotics (e.g., third-generation cephalosporins) and vancomycin. Other approaches are to rotate antibiotics used for empiric therapy and use combinations of drugs from different classes.
OBJECTIVE: This study was undertaken to evaluate the efficacy of 4 new low-temperature sterilization technologies: ethylene oxide with hydrochlorofluorocarbons, a liquid peracetic acid immersion system (Steris System 1 Processor), and 2 plasma sterilization processes that use vaporized hydrogen peroxide (Sterrad 100 and the Sterrad 100S). The Sterrad 100S system potentially improves sterilizer efficacy by using 2 cycles of a diffusion stage and a plasma stage per sterilization cycle. METHODS: Flat stainless steel carriers were inoculated with approximately 10(6) Bacillus stearothermophilus spores. These carriers were aseptically placed in the middle of 40 cm long stainless steel lumens (hollow tubes). Two types of lumen were used:(1) a lumen test unit with a removable 5 cm center piece (1.2 cm diameter) of stainless steel sealed to the narrower steel tubing by hard rubber septums and (2) a straight lumen. Three different diameters of the lumen test unit (1, 2, and 3 mm) and a single diameter of the straight lumen (3 mm) were studied. At least 40 replicates were performed for each type of lumen and sterilization method. After inoculation, the test unit was evaluated in 1 of the low-temperature sterilization technologies. After sterilization, the carriers were cultured in trypticase soy broth for 14 days at 55 degrees C and assessed for growth of B stearothermophilus spores. RESULTS: Our results demonstrated that ethylene oxide with hydrochlorofluorocarbons, the Sterrad 100s, and the Sterrad 100S half cycle were highly effective in killing approximately 10(6) B stearothermophilus spores present in the center of narrow-lumen stainless steel tubes. As the lumen diameter decreased with the lumen test unit, the Sterrad 100 demonstrated reduced ability to kill B stearothermophilus spores present on the carrier. At the smallest diameter tested (1 mm), the Sterrad 100 system failed 74% of the time. The Steris System 1 was not effective in completely eliminating the 10(6) inoculum under test conditions. CONCLUSION: The Sterrad 100S was significantly superior to the Sterrad 100 system and equivalent to ethylene oxide with hydrochlorofluorocarbons. Introduction of this new Sterrad 100S system should improve the margin of safety and reduce processing costs by its use of a shorter cycle time. The Steris System 1 is limited by diffusion of the chemical sterilant into the interior of the lumen test unit.
OBJECTIVE: To ascertain the microbial load and type of organisms on used surgical instruments following standard cleaning, which consisted of the use of a washer sterilizer followed by sonic cleaning. DESIGN: In this prospective experimental study, used surgical instruments were immersed in Peptamin Tween broth, the broth agitated, and then filtered through a 0.45 microm filter. Quantitative cultures were performed, and all microbes were identified by using standard techniques. SETTING: This study was conducted at a 660-bed university hospital. RESULTS: The microbial load remaining on used surgical instruments after cleaning was as follows: 36 (72%) instruments 0 to 10 colony-forming units (CFU), 7 (14%) instruments 11 to 100 CFU, and 7 (14%) instruments > 100 CFU. Organisms contaminating the instruments included coagulase-negative staphylococcus (56%) followed by Bacillus (22%) and diphtheroids (14%). No other microbes were isolated from more than 4% of the instruments. CONCLUSION: Most used nonlumen surgical instruments contain less than 100 CFU of relatively nonpathogenic microorganisms after cleaning. This suggests that new low-temperature sterilization technologies are likely to be highly effective in preventing cross-transmission of infection via nonlumen medical instruments.
Explore the source record for details and available documents.
The elimination of chlorofluorocarbons by the Clean Air Act has led to the development of alternative technologies for low-temperature sterilization in the healthcare setting, including 100% ethylene oxide, ethylene oxide with other stabilizing gases, immersion in peracetic acid, and gas plasmas. The ideal sterilant does not exist, and infection control professionals should understand the advantages and disadvantages of these processes. However, when combined with adherence to standard cleaning protocols, the available data suggest that the currently available Food and Drug Administration-cleared low-temperature sterilization technologies can inactivate a clinically relevant inoculum of highly resistant organisms.
Explore the source record for details and available documents.
OBJECTIVES: To determine the stability of sodium hypochlorite (diluted household bleach) when stored for 30 days in various types of containers and to determine the efficacy of low concentrations of free available chlorine to inactivate test bacteria. DESIGN: Laboratory-based study. Solutions of standard household bleach were prepared using tap water or sterile distilled water at dilutions of 1:100, 1:50, and 1:5. Chlorine concentrations were measured, and then the solutions were placed into five polyethylene containers and left at room temperature (20 degrees C) under various conditions (translucent containers with light exposure and with or without air; brown opaque container without light or air exposure). Samples for chlorine and pH determinations were taken at time 0 and on days 7, 14, 21, 30, and 40. Bactericidal activity of chlorine solutions was assessed using the Association of Official Analytical Chemists Use-Dilution Method. Test bacteria included Pseudomonas aeruginosa, Staphylococcus aureus, and Salmonella choleraesuis. RESULTS: Chlorine concentrations at 30 days varied from the 40% to 50% range for 1:50 or 1:100 dilutions stored in containers other than closed brown containers to 83% to 85% for the 1:5 dilution stored in closed but non-opaque containers to 97% to 100% for 1:50 or 1:5 solutions stored in closed brown containers. The lowest concentration of sodium hypochlorite solution that reliably inactivated all the test organisms was 100 ppm. CONCLUSIONS: These data suggest that chlorine solutions do not need to be prepared fresh daily, as is recommended currently, and the lowest concentration of chlorine that reliably inactivates S aureus, S choleraesuis, and P aeruginosa is 100 ppm.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
OBJECTIVE: To evaluate whether hospital strains of antibiotic-resistant bacteria exhibited altered susceptibility to disinfectants. DESIGN: Antibiotic-susceptible bacteria were obtained from American Type Culture Collection: Staphylococcus aureus, Staphylococcus epidermidis, Escherichia coli, Klebsiella pneumoniae, Salmonella choleraesuis, and Pseudomonas aeruginosa. Hospital strains of antibiotic-resistant bacteria were obtained from clinical isolates, including: S aureus, S epidermidis, E coli, Enterococcus species, K pneumoniae, and P aeruginosa. The Association of Official Analytical Chemist's use-dilution method was used to test these 12 strains of 7 bacterial pathogens for their susceptibility to a phenol and a quaternary ammonium compound. For five pathogens, we tested a susceptible and a more resistant strain in 20 comparative trials (5 pathogens, 2 disinfectants, 2 dilutions per disinfectant). RESULTS: In our 20 comparative trials, the antibiotic-resistant strains exhibited an increased resistance to the disinfectant in only a single instance. CONCLUSIONS: Our data demonstrate that the development of antibiotic resistance does not appear to be correlated to increased resistance to disinfectants.
Hypochlorite has been used as a disinfectant for more than 100 years. It has many of the properties of an ideal disinfectant, including a broad antimicrobial activity, rapid bactericidal action, reasonable persistence in treated potable water, ease of use, solubility in water, relative stability, relative nontoxicity at use concentrations, no poisonous residuals, no color, no staining, and low cost. The active species is undissociated hypochlorous acid (HOCl). Hypochlorites are lethal to most microbes, although viruses and vegetative bacteria are more susceptible than endospore-forming bacteria, fungi, and protozoa. Activity is reduced by the presence of heavy metal ions, a biofilm, organic material, low temperature, low pH, or UV radiation. Clinical uses in health-care facilities include hyperchlorination of potable water to prevent Legionella colonization, chlorination of water distribution systems used in hemodialysis centers, cleaning of environmental surfaces, disinfection of laundry, local use to decontaminate blood spills, disinfection of equipment, decontamination of medical waste prior to disposal, and dental therapy. Despite the increasing availability of other disinfectants, hypochlorites continue to find wide use in hospitals.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Varicella-zoster virus (VZV) is the causative agent of two diseases: varicella (chickenpox) and zoster (shingles). Although varicella generally is a mild disease in children, serious morbidity and mortality are common if infection occurs in neonates, pregnant women, adults, or immunocompromised patients. For this reason, the Centers for Disease Control and Prevention recommends that all the hospitals institute control measures. Healthcare workers should be screened for VZV immunity and, if susceptible, should receive the recently licensed Oka/Merck vaccine (unless contraindicated). This article reviews nosocomial outbreaks associated with VZV and provides detailed algorithms for preexposure immunization and postexposure management of healthcare workers exposed to VZV.
The group A streptococcus may cause pharyngitis, rheumatic fever, streptococcal toxic shock syndrome, and serious skin and soft-tissue infections. More than 50 nosocomial outbreaks have been reported since 1966. For this reason, healthcare facilities should develop policies for the diagnosis and treatment of symptomatic hospital employees, and for the recognition and management of potential outbreaks. The clinical diagnosis of streptococcal pharyngitis is unreliable. Rapid streptococcal tests may be used for initial screening, but a negative rapid test should be confirmed with a properly obtained culture. Penicillin remains the treatment of choice, but new alternatives now include a 5-day course of either azithromycin or cefpodoxime.