[Results of using the reflomat for determining glucose concentration, and the influence of glycolysis inhibitors on Reflotest-glucose (author's transl)].

There was a close correlation between the hexokinase-glucose-6-phosphate-dehydrogenase method and reflomat/Reflotest-glucose on capillary blood samples without addition of glycolysis-inhibitors. The relative deviations were less than 10% over the entire range. In systematic studies set up to determine the influence of sodium fluoride and sodium monoiodo-acetate on the reflomat/Reflotest glucose system it was demonstrated that sodium monoiodo-acetate can be used when determining glucose with reflomat/Reflotest glucose, while sodium fluoride produced false values with this system.

Blood Glucose↗

[A simple and quick method for measuring low blood-glucose concentrations (author's transl)].

A new method of measuring glucose concentrations (Reflotest-Hypoglycemie) was tested on 141 serum samples and 119 capillary blood samples and compared with the hexokinase-glucose-6-phosphate dehydrogenase method. The Reflotest (reflectance meter) compared well with the reference test. Comparison of results with three sera measured by the method in six different laboratories indicated the accuracy of the test. Endogenous bilirubin, uric acid, and haematocrit values did not influence the result. The test is therefore suitable for quantitative measurements.

Bilirubin↗

Myoinositol--a uremic neurotoxin?

In 28 patients predialysis plasma myoinositol was significantly elevated to 10.8 +/- 2.5 versus 0.75 +/- 0.15 mg/100 ml in normals (mean +/- 1 SD), and was weakly correlated with plasma creatinine concentrations (r = 0.42, p less than 0.05). Dialysis decreased plasma myoinositol concentrations to 3.5 +/- 1.1 mg/100 ml. In 16 patients studied more extensively plasma myoinositol was similarly elevated to 10.6 +/- 3.4 mg/100 ml, and spinal fluid myoinositol was increased to 9.4 +/- 2.3 mg/100 ml (versus 2.7 +/- 0.7 in normals, p less than 0.001). Nerve conduction velocities were reduced in 15 and EEG tracings were abnormal in 12 of the 16 patients. However, neither spinal fluid nor plasma myoinositol showed any correlation with nerve conduction velocities or EEG changes (r = 0.05-0.20, NS) Myoinositol is one of the substances retained in renal insufficiency but no indication was found that it is a toxin causing uremic neurological disturbances.

Adult↗

[Hemolysis-inducing substances in gastric secretion, incidence-rate of lysolecithin].

Samples of gastric contents from 152 patients with pyloric reflex were taken during gastroscopy after an overnight fast and examined for hemolytic activity. Hemolysis was induced by 97 specimens (64%). The hemolysis test was positive in 45% of patients with a histologically normal gastric mucosa, in 76% of patients suffering from chronic atrophic gastritis with intestinal metaplasia, in 83% with gastric erosions and in 67% with gastric ulcer. No lysolecithin was found in 9 of the 97 positive specimens. The other aspirates contained widely differing values up to 320 mg/100 ml. The average quantities of lysolecithin in gastric contents varied in the different patient groups from 20 to 60 mg/100 ml. These values are much higher than the mean value of 0.9 mg/100 ml quantified in patients without pyloric reflex during an earlier investigation. It is now widely accepted that pyloric reflex promotes gastritis. Furthermore, it has been shown on several occasions that bile constituents exert a damaging effect on the gastric mucosa barrier. The same is true of lysolecithin, which promotes (for example) acute cholecystitis under experimental conditions. These findings, together with the results of our investigation, seem to afford evidence that lysolecithins may exert a pathogenic influence in the development of different gastric lesions.

Female↗

[Isolation, identification and quantitative determination of lysolecithin in the human gastric juice].

Lysolecithin was isolated and identified from the gastric contents of 5 patients with gastric ulcer and erosive and atrophic gastritis. The methods used involved methanolic extration, column chromatography on silica gel and sephadex gel filtration, followed by preparative thin layer chromatography. Identification of lysolecithin was verified in one sample by thin layer chromatography and elementary analysis. A method for quantitation of lysolecithin in human gastric fluid for routine clinical analysis is described, based on the procedure used for identification of this phospholipid. Further, a hemolysis test is proposed for screening gastric contents for lysolecithin concentrations above approximately 10 mg/100 ml. With the quantitative method, an average concentration of 66.1 mg of lysolecithin in 100 ml gastric content was found in the group of 5 patients. The screening test was positive in all 5 samples, but was negative with native gastric juice in 25 persons serving as controls. When the gastric fluid of the controls was concentrated, however, 9 samples gave a positive hemolytic reaction. From these 9 specimens, the lysolecithin concentration was found to average 0.9 mg/100 ml. These findings afford evidence that lysolecithin may be involved as a factor in the pathogenesis of gastric ulceration.

Chromatography, Thin Layer↗