Evaluation of a new electromagnetic tracking system using a standardized assessment protocol.

This note uses a published protocol to evaluate a newly released 6 degrees of freedom electromagnetic tracking system (Aurora, Northern Digital Inc.). A practice for performance monitoring over time is also proposed. The protocol uses a machined base plate to measure relative error in position and orientation as well as the influence of metallic objects in the operating volume. Positional jitter (E(RMS)) was found to be 0.17 mm +/- 0.19 mm. A relative positional error of 0.25 mm +/- 0.22 mm at 50 mm offsets and 0.97 mm +/- 1.01 mm at 300 mm offsets was found. The mean of the relative rotation error was found to be 0.20 degrees +/- 0.14 degrees with respect to the axial and 0.91 degrees +/- 0.68 degrees for the longitudinal rotation. The most significant distortion caused by metallic objects is caused by 400-series stainless steel. A 9.4 mm maximum error occurred when the rod was closest to the emitter, 10 mm away. The improvement compared to older generations of the Aurora with respect to accuracy is substantial.

Austria↗

Fast DRR generation for 2D/3D registration.

We present a simple and rapid method for generation of perspective digitally rendered radiographs (DRR) for 2D/3D registration based on splat rendering. Suppression of discretization artefacts by means of computation of Gaussian footprints--which is a considerable computational burden in classical splat rendering--is replaced by stochastic motion of either the voxels in the volume to be rendered, or by simulation of a X-ray tube focal spot of finite size. The result is a simple and fast perspective rendering algorithm using only a small subset of voxels. Our method generates slightly blurred DRRs suitable for registration purposes at framerates of approximately 10 Hz when rendering volume images with a size of 30 MB on a standard PC.

Algorithms↗

Risk analysis and safety assessment in surgical robotics: a case study on a biopsy robot.

One of the most important issues in medical robotics is safety and integration into the clinical workflow. If a robot is not safe and its use is complicated by difficult handling and complex user interfaces physicians would not use a robotic system during clinical patient trials, whatever the other advantages are. However, there are only few publications on this topic, in particular on risk management in developing a robotic prototype (for clinical trials). In this paper risk management and the safety of using robot-assisted surgery equipment are discussed and demonstrated exemplarily in the process of developing a prototype biopsy robot.

Journal Article↗

Quantitative analysis of factors affecting intraoperative precision and stability of optoelectronic and electromagnetic tracking systems.

This study aims to provide a quantitative analysis of the factors affecting the actual precision and stability of optoelectronic and electromagnetic tracking systems in computer-aided surgery under real clinical/intraoperative conditions. A "phantom-skull" with five precisely determined reference distances between marker spheres is used for all measurements. Three optoelectronic and one electromagnetic tracking systems are included in this study. The experimental design is divided into three parts: (1) evaluation of serial- and multislice-CT (computed tomography) images of the phantom-skull for the precision of distance measurements by means of navigation software without a digitizer, (2) digitizer measurements under realistic intraoperative conditions with the factors OR-lamp (radiating into the field of view of the digitizer) or/and "handling with ferromagnetic surgical instruments" (in the field of view of the digitizer) and (3) "point-measurements" to analyze the influence of changes in the angle of inclination of the stylus axis. Deviations between reference distances and measured values are statistically investigated by means of analysis of variance. Computerized measurements of distances based on serial-CT data were more precise than based on multislice-CT data. All tracking systems included in this study proved to be considerably less precise under realistic OR conditions when compared to the technical specifications in the manuals of the systems. Changes in the angle of inclination of the stylus axis resulted in deviations of up to 3.40 mm (mean deviations for all systems ranging from 0.49 to 1.42 mm, variances ranging from 0.09 to 1.44 mm), indicating a strong need for improvements of stylus design. The electromagnetic tracking system investigated in this study was not significantly affected by small ferromagnetic surgical instruments.

Biophysical Phenomena↗

Local calibrated bone mineral density in the mandible presented using a color coding scheme.

Calibrated information on bone mineral density (BMD) may be used in dental implantology to measure "bone quality". It can be used to estimate the expected primary implant stability preoperatively and to guide the surgeon in selecting optimum implant types and operation techniques. Using a preoperative dental computed tomography (Dental-CT) scan, all of this information can be obtained without additional examinations and thus without additional X-ray exposure of the patient. In contrast to bone mineral determination in other body regions, local BMD values are important in the jaw bone. Therefore, a regimen where color-coded information on local bone mineralization is superimposed on Dental-CT images is proposed using the original CT volumes as well as reformatted views.

Bone Density↗

In-vitro assessment of a registration protocol for image guided implant dentistry.

In this study a computer aided navigation technique for accurate positioning of oral implants was assessed. An optical tracking system with specially designed tools for monitoring the position of surgical instruments relative to the patient was used to register 5 partially or completely edentulous jaw models. Besides the accuracy of the tracking system, the precision of localizing a specific position on 3-dimensional preoperative imagery is governed by the registration algorithm which conveys the coordinate system of the preoperative computed tomography (CT) scan to the actual patient position. Two different point-to-point registration algorithms were compared for their suitability for this application. The accuracy was determined separately for the localization error of the position measurement hardware (fiducial localization error-FLE) and the error as reported by the registration algorithm (fiducial registration error-FRE). The overall error of the navigation procedure was determined as the localization error of additional landmarks (steel spheres, 0.5 mm diameter) after registration (target registration error-TRE). Images of the jaw models were obtained using a high resolution CT scan (1.5 mm slice thickness, 1 mm table feed, incremental scanning, 120 kV, 150 mAs, 512 x 512 matrix, FOV 120 mm). The accuracy of the position measurement probes was 0.69 +/- 0.15 mm (FLE). Using 3 implanted fiducial markers, FRE was 0.71 +/- 0.12 mm on average and 1.00 +/- 0.13 mm maximum. TRE was found to be 1.23 +/- 0.28 mm average and 1.87 +/- 0.47 mm maximum. Increasing the number of fiducial markers to a total of 5 did not significantly improve precision. Furthermore it was found that a registration algorithm based on solving an eigenvalue problem is the superior approach for point-to-point matching in terms of mathematical stability. The experimental results indicate that positioning accuracy of oral implants may benefit from computer aided intraoperative navigation. The accuracy achieved compares well to the resolution of the CT scan used. Further development of point-to-point/point-to-surface registration methods and tracking hardware has the potential to improve the precision of the method even further. Our system has potential to reduce the intraoperative risk of causing damage to critical anatomic structures, to minimize the efforts in prosthetic modelling, and to simplify the task of transferring preoperative planning data precisely to the operating room in general.

Algorithms↗

Principles of computer-assisted arthroscopy of the temporomandibular joint with optoelectronic tracking technology.

PURPOSE: This preliminary clinical study evaluated the applicability, accuracy, and benefits of computer-assisted arthroscopy of the temporomandibular joint (TMJ) with optoelectronic tracking technology. MATERIALS AND METHODS: A hybrid of reality and virtual reality is built as a composite-reality environment by extracting 3-dimensional anatomical structures through use of computed tomography, magnetic resonance imaging, radiography, and other types of imaging procedures commonly used in clinical praxis. These various independent sources of imaging data of a particular patient can be combined with and complemented by complex graphic simulations. Intraoperatively they are merged with online position data of surgical instruments inside the patient's TMJ. This hybrid model of detailed anatomical structures, guidelines, and real-time instrument positions allows the surgeon to accurately plan the arthroscopic intervention as well as to navigate effectively intraoperatively. RESULTS: In the first 10 cases of computer-assisted TMJ arthroscopy, composite reality environment technology permitted the online visualization of TMJ structures, puncture sites, instrument positions, and virtual pathways in relation to anatomical landmarks with high spatial accuracy (minimum, 0.0 mm; maximum, 2.5 mm; mean, 1.4 mm; SD, 0.6 mm) and high temporal resolution (100 ms). Past, present, and possible future instrument positions can be displayed. The application of computer-assisted arthroscopy caused little immobility for either surgeon or patient. CONCLUSION: Even experienced surgeons profit from improved precision in the handling of the arthroscope; thus this technology was found to be particularly useful in degenerative temporomandibular disorders and for triangulation procedures.

Arthroscopes↗

Placement of endosteal implants in the zygoma after maxillectomy: a Cadaver study using surgical navigation.

Endosteal implants facilitate obturator prosthesis fixation in tumor patients after maxillectomy. Previous clinical studies have shown, however, that the survival of implants placed into available bone after maxillectomy is generally poor. Nevertheless, implants positioned optimally in residual zygomatic bone provide superior stability from a biomechanical point of view. In a pilot study, the authors assessed the precision of VISIT, a computer-aided surgical navigation system dedicated to the placement of endosteal implants in the maxillofacial area. Five cadaver specimens underwent hemimaxillectomy. The cadaver head was matched to a preoperative high-resolution computed tomograph by using implanted surgical microscrews as fiducial markers. The position of a surgical drill relative to the cadaver head was determined with an optical tracking system. Implants were placed into the zygomatic arch, where maximum bone volume was available. The results were assessed using tests for localization accuracy and postoperative computed tomographic scans of the cadaver specimens. The localization accuracy of landmarks on the bony skull was 0.6 +/- 0.3 mm (average +/- SD), as determined with a 5-df pointer probe; the localization accuracy of the tip of the implant burr was 1.7 +/- 0.4 mm. The accuracy of the implant position compared with the planned position was 1.3 +/- 0.8 mm for the external perforation of the zygoma and 1.7 +/-1.3 mm for the internal perforation. Eight of 10 implants were inserted with maximal contact to surrounding bone, and two implants were located unfavorably. Reliable placement of implants in this region is difficult to achieve. The technique described in this article may be very helpful in the management of patients after maxillary resection with poor support for obturator prostheses.

Cadaver↗

A modular software system for computer-aided surgery and its first application in oral implantology.

Development of complex software applications in image guided therapy (IGT) is often complicated by the fact that providing basic functionality for image processing and user interaction from a graphical user interfaces (GUI) requires considerable manpower for software development. We present a programming environment that combines the high-level image processing library AVW, in-house developed patient-to-image registration procedures, and an interface to position measurement hardware. A specific application can be developed by using Tcl/Tk, a simple platform-independent scripting language, for GUI development. This environment was applied to developing VISIT, a navigation system for computer-aided implant dentistry. VISIT is presented as a result of this paper. Parts of the development environment were made accessible to the public. Future work includes the implementation of video input for connecting ultrasound or fluoroscopy units. We conclude that our approach is well suited to accelerate the development of exploratory new applications of IGT.

Dental Implantation↗

Positioning of dental implants using computer-aided navigation and an optical tracking system: case report and presentation of a new method.

A navigation system for computer-aided surgery (Virtual Patient System, VPS) has been described in previous studies for different indications in oral and maxillofacial surgery. The aim of the system is the intraoperative transfer of preoperative planning on radiographs or CT scans on the patient, in real-time, and independent of the position of the patient's head. Until now an electromagnetic tracking system has been used for intra-operative position measurement. For placement of dental implants, the electromagnetic tracking system is not suitable since the motor of the implant drill leads to a considerable distortion of the magnetic field, thus direct visualization of drilling the implant socket was not possible. To overcome this problem, an optical tracking system which is not disturbed by conductive materials was integrated in the VPS system. The first patient operated on with this system had a posttraumatic loss of the upper incisors; three implants have been placed according to the prosthetic axis previously planned on radiographs and CT scans. The experience gained in this intervention led to the conclusion that computer-aided surgery provides a valuable tool in implant dentistry.

Adult↗

Computer-aided surgery in distraction osteogenesis of the maxilla and mandible.

When using unidirectional intraoral distraction devices, it is desirable to be able to determine the final position of the bone fragment after the distraction procedure. However, additional constraining forces from adjacent tissues render the prediction of the distraction direction difficult. We have utilised computer-aided surgery in three patients for intraoperative control of the distraction direction. In one cleft palate patient, suffering from maxillary hypoplasia and anterior open bite, a modified Le Fort I osteotomy and maxillary distraction was performed. Despite a ventrocaudal position of the distraction device, intraoperative computer visualisation showed an unfavourable caudal vector of distraction without any anterior movement. The final result confirmed the direction indicated by the computer. Maxillary advancement remained insufficient. In two patients suffering from mandibular hypoplasia, intraoperative assessment revealed a favourable direction of distraction. The distraction procedure led to a satisfactory result in both cases. Computer-aided surgery is helpful in assessing the vector of distraction intraoperatively, making the result of the distraction procedure more predictable and allowing instant correction by adequate reapplication of the device.

Adolescent↗

Calibration of tracking systems in a surgical environment.

The purpose of this paper was to assess to what extent an optical tracking system (OTS) used for position determination in computer-aided surgery (CAS) can be enhanced by combining it with a direct current (dc) driven electromagnetic tracking system (EMTS). The main advantage of the EMTS is the fact that it is not dependent on a free line-of-sight. Unfortunately, the accuracy of the EMTS is highly affected by nearby ferromagnetic materials. We have explored to what extent the influence of the metallic equipment in the operating room (OR) can be compensated by collecting precise information on the nonlinear local error in the EMTS by using the OTS for setting up a calibration look-up table. After calibration of the EMTS and registration of the sensor systems in the OR we have found the average euclidean deviation in position readings between the dc tracker and the OTS reduced from 2.9+/-1.0 mm to 2.1+/-0.8 mm within a half-sphere of 530-mm radius around the magnetic field emitter. Furthermore we have found the calibration to be stable after re-registration of the sensors under varying conditions such as different heights of the OR table and varying positions of the OR equipment over a longer time interval. These results encourage the further development of a hybrid magnetooptical tracker for computer-aided surgery where the electromagnetic tracker acts as an auxiliary source of position information for the optical system. Strategies for enhancing the reliability of the proposed hybrid magnetooptic tracker by detecting artifacts induced by mobile ferromagnetic objects such as surgical tools are discussed.

Calibration↗

Systematic distortions in magnetic position digitizers.

Medical devices equipped with position sensors enable applications like image guided surgical interventions, reconstruction of three-dimensional 3D ultrasound (US) images, and virtual or augmented reality systems. The acquisition of three-dimensional position data in real time is one of the key technologies in this field. The systematic distortions induced by various metals, surgical tools, and US scan probes in different commercial electromagnetic tracking systems were assessed in the presented work. A precise nonmetallic six degree-of-freedom measurement rack was built that allowed a quantitative comparison of different electromagnetic trackers. Also, their performance in the presence of large metallic structures was quantified in a phantom study on an acrylic skull model in an operating room (OR). The trackers used were alternating current (ac) and direct current (dc) based systems. The ac trackers were, on average, distorted by 0.7 mm and 0.5 degree by metallic objects positioned at a distance greater than 120 mm between the geometrical center of the sample and the sensor. In the OR environment, the ac system exhibits mean errors of 3.2 +/- 2.4 mm and 2.9 degrees +/- 1.9 degrees. The dc trackers are more sensitive to distortions caused by ferromagnetic materials (averaged value: 1.6 mm and 0.5 degree beyond a distance of 120 mm). The dc tracker shows no distortions from other conductive materials but was less accurate in the OR environment (typical error: 6.4 +/- 2.5 mm and 4.9 degrees +/- 2.0 degrees). At distances smaller than approximately 100 mm between sample and sensor error increases quickly. It is also apparent from our measurements that the influence of US scan probes is governed by their shielding material. The results show that surgical instruments not containing conductive material are to be preferred when using an ac tracker. Nonferromagnetic instruments should be used with dc trackers. Static distortions caused by the OR environment have to be compensated by precise calibration methods.

Acrylates↗