Correlation of microhardness and wear in differently eroded bovine dental enamel.

The purpose of the study was to compare the microhardness data of differently eroded enamel surfaces with the wear caused by toothbrushing. Sixty bovine enamel specimens were polished and prepared for microhardness determination. The polished surfaces were covered with tape except for a 1.3 x 10.0 mm window. Fifteen specimens each were stored in an erosive beverage (Sprite Light) for either 1, 5 or 15 min. Each specimen was immersed in 10 ml of the beverage. The remaining 15 specimens were not eroded. Interferometrical analysis revealed that substance loss after 15 min of erosion was negligibly low (about 75 mm). In all specimens Vickers microhardness determinations were conducted on eroded (= final hardness) and non-eroded (= initial hardness) enamel surfaces. The specimens were subsequently submitted to toothbrushing abrasion using a slurry consisting of 1 g non-fluoridated dentifrice in 5 ml artificial saliva. The total amount of tooth wear due to erosion and subsequent abrasion was profilometrically evaluated. Statistical analysis revealed a significant decrease in hardness and a significant increase in wear with increasing time of storage in the erosive beverage. Overall regression analysis yielded a statistically significant correlation between both initial and final hardness and the amount of tooth wear. The correlation of abrasion and final hardness could be described by a quadratic mathematical function. It is concluded that the susceptibility of eroded enamel to toothbrushing abrasion can be correlated with Vickers microhardness values, thereby suggesting an overproportionate increase of abrasion with decreasing hardness values.

Animals↗

Influence of enamel conditioning on bond strength of resin-modified glass ionomer restorative materials and polyacid-modified composites.

This study evaluated enamel bond strength of restorative materials containing both glass ionomer and composite components. Three resin-modified glass ionomer restorative materials (Fuji II LC, Vitremer, Photac-Fil), three polyacid-modified composites (VariGlass VLC, Dyract, Ionosit Fil), a hybrid composite (blend-a-lux) and a chemical-cured glass-ionomer cement (ChemFil Superior) were tested for enamel tensile bond strength with and without conditioning of the tooth surfaces. Tensile bond strength was determined for five specimens each of conditioned and unconditioned bovine teeth. Specimen conditioning was performed as recommended by the manufacturers. The tensile bond strength was tested with a universal testing machine. Except for the enamel bond strength of ChemFil Superior, all materials showed greater adhesion to conditioned tooth surfaces than to unconditioned specimens. Enamel bond strengths of the polyacid-modified composites applied after a phosphoric acid etching technique (Ionosit Fit, Dyract, VariGlass) were greater compared with the materials applied after surface conditioning with polyacrylic acid-containing agents. No significant difference was observed between the hybrid composite and the tested materials attached with the phosphoric acid etching technique. To improve adhesion of the tested materials to enamel, following the manufacturer's instructions about tooth surface conditioning is recommended. Superior bond strength to enamel was obtained for polyacid-modified composites, which are attached with the phosphoric acid etching technique and thereby resemble the adhesion patterns of composites.

Acid Etching, Dental↗

Influence of dentin conditioning on bond strength of light-cured ionomer restorative materials and polyacid-modified composite resins.

The purpose of the study was to evaluate the dentin bond strength of restorative materials containing both glass ionomer and composite resin components. Three resin-modified glass ionomer restorative materials (Fuji II LC, Photac-Fil, Vitremer), three polyacid-modified composite resins (Dyract, Ionosit Fil, VariGlass VLC), a hybrid composite (blend-a-lux) and a chemical-cured glass ionomer cement (ChemFil Superior) were investigated for dentin tensile bond strength with and without conditioning of the tooth surfaces. For each material, tensile bond strength was determined using five conditioned and five unconditioned bovine tooth specimens. Conditioning of the specimens was performed according to the manufacturers' instructions. The tensile bond strength was tested with a universal testing machine. Statistical analysis was performed with analysis of variance, the Scheffe's-test and the Student's t-test. All materials showed higher adhesion to conditioned dentin than to unconditioned specimens. Except for Photac-Fil, the bond strength to conditioned dentin of all resin-modified glass ionomer restorative materials and polyacid-modified composite resins was higher as compared to the chemical-cured glass ionomer and the hybrid composite. However, these differences were not statistically significant. All polyacid-modified composite resins resulted in higher bond strengths to conditioned dentin as compared to the resin-modified glass ionomer restorative materials. These differences were statistically significant only for VariGlass VLC as compared to Photac-Fil. In order to improve adhesion of the tested materials to dentin it is highly recommended to follow the manufacturers' instructions concerning dentin conditioning.

Acrylic Resins↗

Curing shrinkage and volumetric changes of resin-modified glass ionomer restorative materials.

OBJECTIVES: The objective of the study was to evaluate initial curing shrinkage and volumetric change during water storage of six resin-modified glass ionomer cements (Dyract, DeTrey Dentsply; Fuji II LC, GC Dental Int.; Ionosit Fil, DMG; VariGlass VLC, DeTrey Dentsply; Vitremer, 3M Dental Products; Photac-Fil, ESPE), a hybrid composite (blend-a-lux, Blendax) and a chemical-cured glass ionomer cement (ChemFil Superior, DeTrey Dentsply). METHODS: The curing shrinkage was determined 5 min and 24 h after polymerization and mixing, respectively. Volumetric changes were examined after 14 d and 28 d water storage. Curing shrinkage and volumetric changes were evaluated using the hydrostatic principle. In addition, the total water content of the materials was measured after 28 d water storage. RESULTS: Curing shrinkage of most of the resin-modified glass ionomers was greater than the hybrid composite and the chemical-cured glass ionomer cement. After a 28 d water storage, the resin-modified glass ionomers showed volumetric expansion and the chemical-cured glass ionomer showed volumetric loss. All of the examined glass ionomer materials had a higher total water content than the composite. SIGNIFICANCE. The large curing shrinkage of the resin-modified glass ionomer materials measured in this in vitro study could affect the marginal integrity of glass ionomer restorations.

Acrylic Resins↗

Use of variable remineralization periods to improve the abrasion resistance of previously eroded enamel.

The objective of the study was to evaluate the period of remineralization needed to re-establish the resistance of eroded enamel against brushing abrasion. Enamel specimens were prepared from 84 polished bovine incisors. The samples were evenly distributed among 7 groups (A-G) and submitted to ten alternating de- and remineralization cycles which included abrasion by toothbrushing. Demineralization was accomplished by immersing the specimens in the erosive soft drink Sprite Light((R)) for 1 min. Remineralization was performed by storing the samples in artificial saliva for either 0 min (A), 10 min (B), 60 min (C) or 240 min (D). After each remineralization, the specimens were brushed in an automatic brushing machine. Group E (erosion and 240 min remineralization, but no brushing) group F (erosion, but no remineralization and no brushing), and group G (brushing, but no erosion and no remineralization) served as controls. After performing the cycles, loss of enamel was determined by profilometry. The following values (mean +/- SD) were obtained and statistically analyzed (p<0.05): group A (5.16+/-1.26 microm), B (2.47+/-0.68 microm), C (1.72+/-0.75 microm), D (1.11+/-0.42 microm), E (0.81+/-0. 23 microm), F (1.04+/-0.31 microm), G (0.22+/-0.15 microm). Only the differences between groups D, E, and F were statistically not significant. Under the chosen in vitro conditions, it is concluded that abrasion resistance of eroded enamel continuously increases with remineralization time. However, even after a period of 1 h of remineralization, abrasion of previously eroded enamel is increased

Analysis of Variance↗

In situ evaluation of different remineralization periods to decrease brushing abrasion of demineralized enamel.

The aim of the present in situ study was to evaluate the effect of different periods of intraoral remineralization to decrease the susceptibility of previously demineralized enamel against toothbrushing abrasion. Six human enamel specimens (A-F) were recessed in the buccal aspects of each of eight intraoral appliances which were worn for 21 days by 8 panelists. Demineralization of the samples was performed twice a day extraorally in the acidic beverage Sprite Light for 90 s. Subsequently, the enamel specimens were brushed at different times. Specimen A was brushed immediately after the demineralization. The remaining samples B-E were brushed after the intraoral appliances had been worn for various periods of remineralization: specimen B, 10 min; C, 20 min; D, 30 min and E, 60 min, respectively. Specimen F was only demineralized and remineralized, but not brushed. After 21 days, enamel wear was measured with a laser profilometer. The following values (mean +/- standard deviation) were obtained: specimen A, 6.78+/-2.71 microm; B, 5.47+/-3.39 microm; C, 6.06+/-3.18 microm; D, 5.43+/-2.58 microm; E 4.78+/-2.57 microm, and F 0.66+/-1.11 micro;m. Analysis of variance revealed a significant influence of remineralization period on abrasive wear. However, even after a remineralization period of 60 min the wear was significantly increased as compared to the demineralized, but not brushed control. It is concluded that (1) abrasion resistance of softened enamel increases with remineralization period and (2) at least 60 min should elapse before toothbrushing after an erosive attack.

Amines↗

Optimal camera and illumination angulations for detection of interproximal caries using quantitative light-induced fluorescence.

The aim of the study was to find the optimal illumination and camera angulations for interproximal use of quantitative light-induced fluorescence (QLF). A multiaxis optical bench was developed and interproximal tooth assemblies were investigated using a modified version of QLF. Extracted human premolars without caries (n = 8) and with interproximal D1, D2 and D3 caries (n = 20) were selected. Tooth-pair models without caries and with interproximal caries of matching size, location, and shape were imaged with varying camera and illumination directions from buccal (0 degrees) to occlusal (90 degrees) to lingual (180 degrees) in steps of 30 degrees using a PC and framegrabber and examined for observed presence. Interproximal lesions could be detected in all teeth, but observed presence was dependent on camera angulation (p < 0.05), rather than on illumination angulation (p = 0.32). No caries could be detected with the camera in the 90 degree position.

Bicuspid↗

Residual caries detection using visible fluorescence.

This study investigated the ability of a new fluorescence method to detect residual caries in vitro. Gross caries was removed from 40 teeth with D2 caries. Samples were excited with violet-blue light and viewed through a 530-nm high-pass filter. Residual caries (orange-red fluorescing dentin) was detected in all samples. Further tooth substance was removed from half of the samples until no residual caries was detectable using the new method. Half of the samples remained untreated. A blinded examiner checked all samples for residual caries using DIAGNOdent, a visual tactile examination, and Caries Detector dye. Presence or absence of residual caries in each sample was determined using a fluorescent nucleic acid stain in conjunction with confocal microscopy. The new method, Visible Fluorescence, had the greatest sensitivity, specificity, percent correct score and predictive values of any of the methods tested. The new method had significantly higher percent correct score than any of the other methods and significantly higher specificity than visual tactile and Caries Detector. It was concluded that Visible Fluorescence is an improvement on the currently available aids for residual caries detection.

Bicuspid↗

Susceptibility of enamel surfaces to demineralization after application of fluoridated carbamide peroxide gels.

The aim of the present study was to evaluate the effect of experimental, fluoridated carbamide peroxide gels on formation of erosively induced demineralization of enamel. Seventy-five bovine enamel specimens were polished for microhardness determination and evenly distributed among 5 groups (A-E). The specimens were treated with 10% carbamide peroxide gel (8 h) and subjected twice to remineralization for 2 h in artificial saliva and demineralisation for 90 s in 1% citric acid, pH 2.2. The cycles of treatment with carbamide peroxide and twofold re- and demineralization were repeated three times. The carbamide peroxide gels were different in pH and fluoride content. Gel A (pH 7.0) and gel B (pH 5.7) were fluoridated (0.5% F), gel C (pH 7.0) and gel D (pH 5.7) were not fluoridated. In control group E the samples were not treated with a gel, but stored in 100% humidity for 8 h instead. Knoop microhardness of the specimens was assessed directly after polishing, and after each carbamide peroxide treatment and demineralization. All specimens showed a loss of microhardness at the end of the experiment. After 3 days, the controls revealed a significantly lower hardness loss compared to the specimens treated with the carbamide peroxide gels. Surface softening was significantly lower for the specimens of group A compared to the remaining groups (B-D), which were not significantly different among each other. It is concluded that treatment with either fluoridated or unfluoridated carbamide peroxide gels, at either neutral and acidic pH, renders enamel more susceptible to demineralization. Use of a fluoridated neutral gel decreases the degree of surface softening compared to the other gels investigated.

Analysis of Variance↗

Influence of olive oil emulsions on dentin demineralization in vitro.

The effect of two different concentrations of olive oil emulsions on development of artificial caries-like dentin lesions under severe demineralizing conditions was investigated. Bovine dentin samples (n = 180) were ground flat, polished, divided into four groups, and subjected to three demineralization cycles per day. Samples were stored in one of the following solutions for 5 min prior to demineralization in a buffer solution (pH 5): Group 1: 50% oil emulsion (olive oil and distilled water); group 2: 5% oil emulsion; group 3: distilled water; and group 4: 1,500 ppm sodium fluoride. Daily up to 9 days, lesion depth (ld) and mineral loss (deltaZ) were determined by means of microradiography and analyzed by ANOVA and Tukey's studentized range test (p < or = 0.05). Lesion depth increased with time for all groups. Mineral loss increased in groups 1-3. A small but significant decrease in mineral loss was observed following treatment with lipid emulsions as compared to treatment with distilled water, but fluoride treatment was considerably more effective. Mean mineral loss (means +/- SD in vol% x microm) averaged over the study period was 4,368 +/- 1,599, 4,536 +/- 1,823, 4,849 +/- 1,798, and 789 +/- 177 for group 1, 2, 3, and 4, respectively. Ratio (deltaZ/ld) remained constant around 30 vol% for groups 1-3, but decreased for group 4. In conclusion, externally provided lipids have the potential to reduce dentin demineralization in vitro.

Analysis of Variance↗

Brushing abrasion of softened and remineralised dentin: an in situ study.

The aim of the present in situ study was to evaluate the effect of different periods of intra-oral remineralisation on the susceptibility of softened dentin to toothbrushing abrasion. Groups of 6 human dentin specimens (A-F) were recessed in the buccal aspects of intra-oral appliances which were worn for 21 days by 11 volunteers. The samples were demineralised twice a day extra-orally in the acidic beverage Sprite Light (pH 2.9) for 90 s. Subsequently, the dentin specimens were brushed at different times. Specimen A was brushed immediately after demineralisation. Specimens B-E were brushed after the intra-oral appliances had been worn for various periods in the mouth: specimen B for 10 min, C for 20 min, D for 30 min and E for 60 min. Specimen F was not brushed (control). After 21 days, dentin wear was measured with a profilometer. The following values (means +/- standard deviation) were recorded (microm): A, 23.6 +/- 16.7; B, 37.9 +/- 29.7; C, 31.8 +/- 26.5; D, 18.5 +/- 10.5; E, 15.3 +/- 11.6; F, 12.6 +/- 6.7. There was a statistically significantly increased dentin loss for groups A, B and C as compared to the controls (U test: p < 0.05). However, after intra-oral periods of 30 and 60 min, wear was not significantly higher than in unbrushed controls. It is concluded that for protection of dentin surfaces at least 30 min should elapse before toothbrushing after an erosive attack.

Carbonated Beverages↗

Comparative fluorescence spectroscopy shows differences in noncavitated enamel lesions.

The aim of this study was to compare emission spectra from noncavitated enamel caries with different degrees of discoloration under a wide range of excitation wavelengths. Freshly extracted human molars with white spot, light discolored and dark discolored brown spot enamel caries were selected (n = 4 each). Rectangular blocks (3.5 x 3.5 mm) were cut from the carious area and a corresponding sound area of the same tooth. Emission spectra were recorded from carious and the corresponding sound areas using a fluorescence spectrophotometer at excitation wavelengths from 360 nm up to 580 nm in steps of 20 nm. The specimens were submerged in water during measurement. The spectra were corrected and normalized to peak intensity for comparisons between spectra from sound and carious areas of each tooth. Excitation spectra were recorded for selected emission wavelengths that showed maximum intensity. Emission spectra of all types of carious lesions were shifted towards longer wavelengths (red shift) when compared to the spectra of the corresponding sound enamel. The red shift was highest for dark brown spot lesions and lowest for white spot lesions (p <or= 0.001). Distinct fluorescence bands within 600-700 nm typical for porphyrin compounds were strongest for excitation wavelengths from 400 to 420 nm and present in most of the lesions investigated.

Dental Caries↗

Method to detect minimal amounts of calcium dissolved in acidic solutions.

The study describes the application of the Arsenazo III method for detection of minimal amounts of calcium 12.4-49.4 micromol/l in different acidic solutions (hydrochloric acid, oxalic acid, maleic acid, phosphoric acid, tartaric acid, citric acid, lactic acid and acetic acid) adjusted to pH 2.0, 2.3 and 3.0. A mixture of the respective calcium concentrations with distilled water served as control. The experiments were run with ten repeats in series. Assessment of intra- and interassay coefficient of variation, and lower limit of quantification revealed that depending on the acid used, the Arsenazo III method is a reliable tool to quantify minimal calcium contents in acidic solutions.

Arsenazo III↗

Brushing abrasion of luting cements under neutral and acidic conditions.

Four resin based materials (Compolute Aplicap, ESPE; Variolink Ultra, Vivadent; C&B Metabond, Parkell and Panavia 21, Kuraray), two carboxylate cements (Poly-F Plus, Dentsply DeTrey and Durelon Maxicap, ESPE), two glass-ionomer cements (Fuji I, GC and Ketac-Cem Aplicap, ESPE), one resin-modified glass ionomer cement (Vitremer, 3M) one polyacid-modified resin composite (Dyract Cem, Dentsply DeTrey) and one zinc phosphate cement (Harvard, Richter & Hoffmann) were investigated according to their brushing resistance after storage in neutral and acidic buffer solutions. For this purpose 24 cylindrical acrylic molds were each filled with the materials. After hardening, the samples were stored for seven days in 100% relative humidity and at 37 degrees C. Subsequently, they were ground flat and polished. Then each specimen was covered with an adhesive tape leaving a 4 mm wide window on the cement surface. Twelve samples of each material were stored for 24 hours in a buffer solution with a pH of 6.8. The remaining 12 samples were placed in a buffer with a pH of 3.0. All specimens were then subjected to a three media brushing abrasion (2,000 strokes) in an automatic brushing machine. Storage and brushing were performed three times. After 6,000 brushing strokes per specimen, the tape was removed. Brushing abrasion was measured with a computerized laser profilometer and statistically analyzed with ANOVA and Tukey's Standardized Range Test (p < or = 0.05). The highest brushing abrasion was found for the two carboxylate cements. The lowest brushing abrasion was found for one resin based material, Compolute Aplicap. With the exception of three resin-based materials, a lower pH led to a higher brushing abrasion.

Analysis of Variance↗