Computed tomography of x-ray index of refraction using the diffraction enhanced imaging method.

Diffraction enhanced imaging (DEI) is a new, synchrotron-based, x-ray radiography method that uses monochromatic, fan-shaped beams, with an analyser crystal positioned between the subject and the detector. The analyser allows the detection of only those x-rays transmitted by the subject that fall into the acceptance angle (central part of the rocking curve) of the monochromator/analyser system. As shown by Chapman et al, in addition to the x-ray attenuation, the method provides information on the out-of-plane angular deviation of x-rays. New images result in which the image contrast depends on the x-ray index of refraction and on the yield of small-angle scattering, respectively. We implemented DEI in the tomography mode at the National Synchrotron Light Source using 22 keV x-rays, and imaged a cylindrical acrylic phantom that included oil-filled, slanted channels. The resulting 'refraction CT image' shows the pure image of the out-of-plane gradient of the x-ray index of refraction. No image artefacts were present, indicating that the CT projection data were a consistent set. The 'refraction CT image' signal is linear with the gradient of the refractive index, and its value is equal to that expected. The method, at the energy used or higher, has the potential for use in clinical radiography and in industry.

Models, Statistical↗

Human breast cancer specimens: diffraction-enhanced imaging with histologic correlation--improved conspicuity of lesion detail compared with digital radiography.

Seven breast cancer specimens were examined with diffraction-enhanced imaging at 18 keV with a silicon crystal with use of the silicon 333 reflection in Bragg mode. Images were compared with digital radiographs of the specimen, and regions of increased detail were identified. Six of the seven cases (86%) showed enhanced visibility of surface spiculation that correlated with histopathologic information, including extension of tumor into surrounding tissue.

Biopsy, Needle↗

Single-and dual-energy CT with monochromatic synchrotron x-rays.

We explored the potential for clinical research of computed tomography (CT) with monochromatic x-rays using the preclinical multiple energy computed tomography (MECT) system at the National Synchrotron Light Source. MECT has a fixed, horizontal fan beam with a subject apparatus rotating about a vertical axis; it will be used for imaging the human head and neck. Two CdWO4-photodiode array detectors with different spatial resolutions were used. A 10.5 cm diameter acrylic phantom was imaged with MECT at 43 keV and with a conventional CT (CCT) at 80 kVp: spatial resolution approximately equal to 6.5 line pairs (lp)/cm for both; slice height, 2.6 mm for MECT against 3.0 mm for CCT; surface dose, 3.1 cGy for MECT against 2.0 cGy for CCT. The resultant image noise was 1.5 HU for MECT against 3 HU for CCT. Computer simulations of the same images with more precisely matched spatial resolution, slice height and dose indicated an image-noise ratio of 1.4:1.0 for CCT against MECT. A 13.5 cm diameter acrylic phantom imaged with MECT at approximately 0.1 keV above the iodine K edge and with CCT showed, for a 240 micrograms I ml-1 solution, an image contrast of 26 HU for MECT and 13 and 9 HU for the 80 and 100 kVp CCT, respectively. The corresponding numbers from computer simulation of the same images were 26, 12, and 9 HU, respectively. MECT's potential for use in clinical research is discussed.

Acrylates↗

Mammographic phantom studies with synchrotron radiation.

PURPOSE: To explore the potential improvement in image contrast for breast imaging with use of monoenergetic photons. MATERIALS AND METHODS: The x-ray energy available from the National Synchrotron Light Source is from 5 to over 50 keV. A specific energy is selected with a tunable crystal monochromator. The object is scanned with a narrow beam of 80.0 x 0.5 mm. Mammography phantoms were imaged with plate and film as the imaging detectors. Phantom images were obtained at 16-24 keV and compared with images obtained with a conventional mammographic unit. RESULTS: Preliminary findings indicate improved image contrast of the monoenergetic images compared with that obtained from the conventional x-ray source, particularly at 18 keV and below. CONCLUSION: Pilot results are encouraging, and the authors presently continue to explore monoenergetic photon imaging with improved instrumentation, scatter rejection, and use of tissue samples.

Breast Neoplasms↗

Photon activation of iododeoxyuridine: biological efficacy of Auger electrons.

Photon activation therapy is a binary system being investigated as a potential therapeutic modality to improve the treatment of malignancies, particularly the highly lethal and malignant brain tumor, glioblastoma multiforme. Its success relies upon the incorporation of a target atom in the immediate vicinity of a tumor cell's critical site, followed by the activation of this atom with photons of energies suitable for the induction of the photoelectric effect and its concomitant Auger cascades. The collective action of the Auger electrons imparts high-LET type damage at the critical site. Photon activation therapy uses iodine from stable iododeoxyuridine (IdUrd) as the target atom, and monochromatic photons above the K absorption edge of iodine (33.2 keV) as the activating agent. Although IdUrd is a cell-sensitizing agent, work described was designed to separate the biological efficacy due to sensitization from that of the Auger effect. Chinese hamster V79 cells with and without IdUrd in cellular DNA were irradiated at the X17B1 beam line in the National Synchroton Light Source of Brookhaven National Laboratory. Monochromatic photons above (33.4 keV) and below (32.9 keV) the K absorption edge were used to determine if any additional biological damage would accrue from the Auger cascades. The 33.4-keV photons were found to be a factor of 1.4 times more effective than 32.9-keV photons in damaging iodinated cells. The sensitizing effect, evaluated separately, was found to be a factor of 2.2 at 10% survival, regardless of photon energy. Thus the total therapeutic gain was 1.4 x 2.2 = 3.1. Irradiations of noniodinated control cells showed no difference in their response to energies above and below the iodine K edge.

Animals↗