PubMed Health⌕ Search

Biomedical subjects

W Castaneda

Publications and source records attributed to W Castaneda.

7 recordsLinked to original sources

Using a symbiotic man/machine approach to evaluating visual clinical research data.

Some candidate medical expert system applications have a significant visual component. Knowledge engineers usually dismiss such task domains as potential expert systems applications. Our success in developing ESCA, a system for evaluating serial coronary angiograms, shows that such task domains should not be dismissed so quickly. We used a symbiotic approach between man and machine, where technologists provide the visual skills with an expert system imitating the conceptual skills of the expert, to produce a partially automated system that is more consistent and cost effective than one that is fully manual. The agreement between the system's conclusions and that of a panel of experts is good. The expert system actually has a slightly higher agreement rate with the expert panel than the agreement rate between two expert panel teams evaluating the same film pair.

Angiocardiography↗

Maximal postextrasystolic potentiation following multiple extrasystoles: a simple means of myocardial assessment.

To obtain consistent, reproducible postextrasystolic potentiation (PESP), a single closely coupled extrasystole (ES) must be introduced using transvenous pacing. We hypothesized that multiple ES (spontaneous or catheter induced) produce maximal PESP at all coupling intervals (CI). Differences in PESP between single and double ES were assessed in dogs at varying CI by two different methods [systolic time intervals--PEP/LVET, and endocardial markers--ejection fraction (EF)]. Single ES produced variable decreases in PEP/LVET (-8.6 +/- 2.7% (SE) to -22.9 +/- 4.0%) depending on the CI duration. Double ES produced maximal decreases (-26.0 +/- 1.2%) at all CI. A similar relationship was noted for EF following single ES (8.6 +/- 2.7% to 43.0 +/- 4.0%) and double ES (42.9 +/- 1.3%). Double ES produced maximal PESP at all CI. This finding may allow simple myocardial assessment during routine left ventricular catheterization without simultaneous right ventricular catheterization.

Animals↗

Influence of aspirin and dipyridamole on patency of coronary artery bypass grafts.

A prospective randomized trial was performed to determine if the administration of inhibitors of platelet function would improve the patency of coronary artery bypass grafts. Patients were operated on for intractable angina with angiographically demonstrable lesions. The left internal mammary artery (IMA) was used for bypass of lesions of the left anterior descending coronary artery (LAD). Saphenous vein grafts were used for the LAD if the IMA was inadequate and for all other vessels. Treated patients received 1,300 mg of aspirin and 100 mg of dipyridamole (Persantine) orally each day. Control patients received neither drug. Patients returned 3 to 6 months after operation for repeat angiography. Results were analyzed by chi-square. One hundred seventy-four patients entered the study from June, 1973, through December, 1975, and 113 were analyzed. In the control group, 66 patients had 27 IMA-LAD grafts and 93 saphenous vein grafts. In the treatment group, 47 patients underwent 18 IMA-LAD grafts and 75 saphenous vein grafts. Ninety-eight of the 120 grafts (82%) were patent in the control group, and 87 of 93 grafts (94%) were patent in the treatment group (x2 = 6.34, p less than 0.02). Of the 45 IMA-LAD grafts in both groups, only 1 was occluded, a patency of 98%. In the control group, 72 of 93 saphenous vein grafts (77%) were patent. In the treatment group, 69 of 75 (92%) were patent (x2 = 6.54, p less than 0.02). The results of the study show a 15% difference between the two groups in the early patency of saphenous vein grafts. We continue to use aspirin and dipyridamole to improve the patency of saphenous vein bypass grafts.

Aspirin↗

Percutaneous cervical central venous line placement: a comparison of the internal and external jugular vein routes.

To compare the rate of success and incidence of complications associated with two currently popular routes of percutaneous central venous cannulation, we studied 167 patient in whom either internal or external jugular vein catheterization was attempted. Internal jugular vein (IJV) catheterization (125 patients) was successful in 91%; an intrathoracic location was achieved in 100%; complications occurred in 12.8%. Complications included one case of catheter malposition, one case of tension pneumothorax, and 12 instances of inadvertent carotid artery puncture, one resulting in a paratracheal hematoma and phrenic nerve compression. The success rate of IJV cannulation was higher and carotid artery puncture less frequent when an 18-gauge thin-walled needle and a straight guide-wire were used than when IJV cannulation was performed by bind puncture with a larger over-the-needle catheter. Delayed vein perforation occurred twice. External jugular vein cannulation (42 patients), using a "J" wire technique, yielded a 76% success rate: 93.7% of catheter tips reached an intrathoracic location. No complications occurred. We conclude that IJV cannulation is a more reliable means of percutaneous central venous line placement but is associated with a significant incidence of complications which can be reduced if a technique employing a scout needle and guide-wire is used.

Adolescent↗

Redistribution of renal blood flow caused by contrast media.

Rerouting of blood from the renal cortex to the renal medulla (Trueta shunting), observed in 5 cases, may occur in normal kidneys during renal angiography. The temporary nature of this artifact may be proved by performing an abdominal aortogram with the catheter tip inserted farther away from the renal arteries. The exact mechanism of this phenomenon is unknown; it may also occur with various renovascular disorders.

Adult↗

Direct injection into the gallbladder in dogs, using ultrasonic guidance.

Direct injection into the gallbladder can be accomplished with the guidance of the ultrasonic aspiration transducer. Possible bile peritonitis is a limiting factor, but not necessarily a complication that contraindicates the procedure. Some modifications of the procedure may be necessary, and further investigation into this potentially valuable procedure is indicated.

Animals↗

Peripheral angiograph enhancement by long leg pneumatic boots.

In patients with arterial occlusive disease it is virtually impossible to predict the speed of blood flow due to the presence of stenoses, occlusions, and collaterals. Repeated exposures and injections can be avoided by the use of pneumatic boots which increase peripheral blood flow by reactive hyperemia, are well tolerated by patients, and decreases the pain associated with injection of contrast material.

Angiography↗