The impact of balloon material and lesion characteristics on the incidence of angiographic and clinical complications of coronary angioplasty.

To assess the importance of balloon material used for percutaneous transluminal coronary angioplasty (PTCA), we compared the complication rates observed with low complaint plastomer (PM 300), intermediately compliant polyethylene (PE 600), and highly compliant polyolefin copolymer (POC) balloons. In a total of 1,650 procedures, one of these balloon materials was used to dilate 2,040 lesions. The dissection rate tended to be slightly lower with the use of more compliant balloon material. The total clinical complication rate (death, emergency coronary surgery, myocardial infarction, need for bail-out stenting or for prolonged heparin treatment, abrupt out-of-laboratory vessel closure) was 8.1%, 7.4%, and 4.2% in the procedures exclusively performed with PM 300 (N = 653), PE 600 (N = 543) and POC (N = 454) balloons, respectively (P = 0.03). In multivariate analysis, the use of less compliant balloon material emerged as an independent correlate of clinical complications (P = 0.007). However, the predictive power of the lesion complexity (B2, C versus A, B1) was four times stronger. In contrast to current concerns, the use of compliant balloon material seems at least as safe as the use of less compliant material.

Aged↗

Intravascular ultrasound versus angiography for measurement of luminal diameters in normal and diseased coronary arteries.

Quantitation of coronary luminal diameter with a 20 MHz mechanically rotating intravascular ultrasound (IVUS) catheter was compared with orthogonal-view cineangiography by use of a semiautomated edge-detection algorithm in 48 patients undergoing coronary angioplasty. Quantitative comparison of 196 matched segments was attempted, but in only 174 (88.8%) was a direct comparison of the two techniques possible. In angiographically normal coronary arteries (46 segments) the correlation between the values obtained by quantitative coronary angiography (QCA) and those achieved by IVUS was excellent (r = 0.92, p < 0.0001). For mild stenoses (80 segments) the correlation coefficient was only fair (r = 0.467, p < 0.001). After percutaneous transluminal coronary angioplasty the correlation coefficient between IVUS and QCA data (48 segments) was very weak (r = 0.282, p < 0.05). In conclusion, coronary IVUS is feasible and safe and even for a limited range of coronary arterial narrowing, significant correlations between IVUS and QCA measurements of minimal lumen diameter were found. They were excellent in normal coronary arteries, moderate in mildly diseased arteries, and weak after balloon angioplasty.

Angioplasty, Balloon, Coronary↗

Angiotensin-converting enzyme inhibition with fosinopril sodium in the prevention of restenosis after coronary angioplasty.

BACKGROUND: Several angiotensin-converting enzyme inhibitors have antiproliferative effects in a rat model after carotid artery balloon injury. METHODS AND RESULTS: We conducted a randomized, double-blind, placebo-controlled trial to assess the effect of fosinopril, a novel angiotensin-converting enzyme inhibitor, in restenosis prevention after percutaneous transluminal coronary angioplasty (PTCA). Patients received fosinopril or matched placebo 10 mg at least 18 hours before PTCA, 20 mg at least 4 hours before PTCA, and 40 mg daily for 6 months. In addition, all patients received aspirin. Coronary angiograms before PTCA and immediately after PTCA as well as at 6-month follow-up were quantitatively analyzed. A total of 509 patients were recruited. The final per-protocol population consisted of 153 fosinopril-treated and 151 placebo-treated patients. Restenosis rates according to the National Heart, Lung, and Blood Institute criterion 4 (loss of > or = 50% of the initial gain [primary end point]) were 45.7% and 40.7% in the fosinopril and control groups, respectively (not significant). The respective mean differences in minimal coronary luminal diameter between post-PTCA and follow-up angiograms were -0.59 +/- 0.71 mm and -0.51 +/- 0.67 mm (not significant). Clinical events during the 6-month follow-up period, analyzed on an on-treatment basis, were ranked according to the most serious event. The respective numbers in the fosinopril and the control groups were for death, 0 and 0; myocardial infarction, 0 and 0; coronary artery bypass graft surgery, 1 and 3; repeat PTCA, 35 and 35; recurrent signs of ischemia necessitating early repeat coronary angiography and managed medically, 6 and 7; and none of the above, 111 and 106. All these differences were significant. CONCLUSIONS: Administration of fosinopril in a dose of 40 mg daily during 6 months after PTCA does not prevent restenosis and has no effect on overall clinical outcome.

Angioplasty, Balloon, Coronary↗

Intra- and interobserver variability of a fast on-line quantitative coronary angiographic system.

To evaluate intra- and interobserver variability of an on-line quantitative coronary angiographic system, 2 independent observers measured 166 primary lesions excluding total occlusions before and after coronary angioplasty. Each observer repeated his measurement 3 times at 14 days interval. The average percent diameter stenosis results obtained by observer 1 and 2 were almost identical, before (62.2% +/- 12.0% and 62.6% +/- 11.4%, NS) and after (27.1% +/- 12.0% and 26.9% +/- 11.3%, NS) angioplasty. Variability was expressed as 95% limits of agreement (mean difference +/- 2 x SD). The intra-observer variability of observer 1 ranged from -6.6% to 6.6% before angioplasty and from -9.6% to 9.6% after angioplasty. The corresponding limits of observer 2 were -8.0% to 7.5% and -8.3% to 8.5%, respectively. The interobserver variability ranged from -10.4% to 9.6% before versus -12.5% to 13.1% after angioplasty. This variability was not influenced by vessel size. The widening of the limits observed after angioplasty was largely due to an increased variability in the measurements of the absolute minimal luminal diameter but not of the reference segment. We conclude that the intra- and interobserver variability of measurements obtained with an on-line quantitative angiographic system used for guiding coronary interventions is acceptable and without systematic bias in any direction for a wide range of primary coronary stenoses. However, the variability increases when images are acquired immediately after angioplasty.

Angioplasty, Balloon, Coronary↗

Immediate and 6-month follow-up results of coronary angioplasty for restenosis: analysis of factors predicting recurrent clinical restenosis.

To determine the results of coronary angioplasty for a first restenosis, the clinical, anatomic, and procedural data of 400 consecutive patients were compared with the data of 507 consecutive patients undergoing a first angioplasty. After angioplasty for restenosis, emergency redilatation had to be performed in only 0.7% of the patients versus 3.1% of the control group (p = 0.02); nevertheless, the major in-hospital event (death, myocardial infarction, emergency coronary surgery, cerebrovascular accident) rate for patients was only slightly lower (3.3% vs 4.2%, p = NS). During the 6-month follow-up period, there were no cardiac deaths and only two myocardial infarctions in the study group, but recurrent ischemia was more frequent (37% vs 31%, p = 0.05) and resulted in considerably more elective coronary surgery (16% vs 2.6%, p = 0.001). In the study group, stepwise discriminant analysis revealed four variables significantly related to the occurrence of a second restenosis: time interval between first and second angioplasty, male gender, severity of angina, and complexity of the restenotic lesions. However, their individual predictive power was low. In conclusion, compared with angioplasty for primary lesions, angioplasty for restenosis was associated with fewer periprocedural complications and, after a 6-month follow-up, serious cardiac events were almost nonexistent but recurrent ischemia was more frequent.

Aged↗

Isolated single coronary artery: a review of 50,000 consecutive coronary angiographies.

Single coronary artery is a rare congenital anomaly of the coronary arteries where only one coronary artery arises from the aortic trunk by a single coronary ostium, supplying the entire heart. A database consisting of the angiographic reports of 50,000 consecutive coronary angiographies performed in adult patients in the University Hospital of Leuven between March 1973 and August 1991 was searched for the diagnosis of single coronary artery. All films concerned were reviewed and classified according to their anatomical type. Thirty-three cases of single coronary artery were retrieved, yielding an incidence of 0.066%. Patient characteristics and clinical data are described, with a discussion on the pathological importance of this finding.

Adult↗

Functional recovery of subepicardial myocardial tissue in transmural myocardial infarction after successful reperfusion: an important contribution to the improvement of regional and global left ventricular function.

BACKGROUND: The transmural extent of myocardial necrosis after an acute coronary artery occlusion can vary considerably. The contribution of residual subepicardial viable myocardium to global left ventricular function is largely unknown. METHODS AND RESULTS: We studied 12 patients with single-vessel disease 1 week after successful reperfusion of a first transmural anterior myocardial infarction (MI). With PET, myocardial blood flow (MBF) and glucose metabolism were measured regionally, and the viability was graded as normal, mismatch, or match with severely (<50% of normal) or intermediately (50% to 80% of normal) impaired MBF. Magnetic resonance tagging was used to regionally quantify fiber strains, wall thickening, and ejection fraction in patients 1 week and 3 months after the MI and in age-matched healthy volunteers. From 1 week to 3 months, subepicardial fiber shortening improved significantly in the match region (MBF <50%, -5.1+/-7.0% to -9.9+/-8. 7%; MBF of 50% to 80%, -7.1+/-7.6% to -14.9+/-7.9%). This was associated with an improvement in regional ejection fraction in the infarcted myocardium (29.6+/-21.8% to 43.5+/-15.5%, P<0.0001) and in normal regions (54.3+/-15.1% to 56.5+/-13.1%, P=0.013), contributing to an increase in global ejection fraction from 44.2+/-22.2% to 49. 3+/-17.9% (P<0.0001). CONCLUSIONS: Functional recovery of viable subepicardial regions is a mechanism of late improvement in regional and global ejection fraction after a so-called transmural MI.

Aged↗