Image segmentation of trabecular spongiosa by visual inspection of the gradient magnitude.

Recent advances in physical models of skeletal dosimetry utilize high-resolution 3-dimensional microscopic computed tomography images of trabecular spongiosa. These images are coupled to radiation transport codes to assess energy deposition within active bone marrow and trabecular endosteum. These transport codes rely primarily on the segmentation of the spongiosa images into bone and marrow voxels. Image thresholding has been the segmentation of choice for bone sample images because of its extreme simplicity. However, the ability of the segmentation to reproduce the physical boundary between bone and marrow depends on the selection of the threshold value. Statistical models, as well as visual inspection of the image, have been employed extensively to determine the correct threshold. Both techniques are affected by partial volume effect and can provide unexpected results if performed without care. In this study, we propose a new technique to threshold trabecular spongiosa images based on visual inspection of the image gradient magnitude. We first show that the gradient magnitude of the image reaches a maximum along a surface that remains almost independent of partial volume effect and that is a good representation of the physical boundary between bone and marrow. A computer program was then developed to allow a user to compare the position of the iso-surface produced by a threshold with the gradient magnitude. The threshold that produces the iso-surface that best coincides with the maximum gradient is chosen. The technique was finally tested with a set of images of a true bone sample with different resolutions, as well as with three images of a cube of Duocell aluminium foam of known mass and density. Both tests demonstrate the ability of the gradient magnitude technique to retrieve sample volumes or media volume fractions with 1% accuracy at 30 microm voxel size.

Aluminum Compounds↗

Tomographic physical phantom of the newborn child with real-time dosimetry I. Methods and techniques for construction.

A tomographic phantom representing a newborn female patient was constructed using tissue-equivalent materials previously developed at the University of Florida. This phantom was constructed using contoured images from an actual patient data set, a whole-body computed tomography of a newborn cadaver previously described by Nipper et al. [Phys. Med. Biol. 47, 3143-1364 (2002)]. Four types of material are incorporated in the phantom: soft tissue, bone tissue, lung tissue, and air. The phantom was constructed on a slice-by-slice basis with a z-axis resolution of 5 mm, channels for dosimeters (thermoluminescent dosimeter (TLD), metal-oxide-semiconductor field-effect transistor, or gated fiber-optic-coupled dosimeter (GFOC)) were machined into slices prior to assembly, and the slices were then fixed together to form the complete phantom. The phantom will be used in conjunction with an incorporated dosimetry system to calculate individual organ and effective doses delivered to newborn patients during various diagnostic procedures, including, but not limited to, projection radiography and computed tomography. Included in this paper are images detailing the construction process, and images of the completed phantom.

Computer Systems↗

MOSFET dosimeter depth-dose measurements in heterogeneous tissue-equivalent phantoms at diagnostic x-ray energies.

The objective of the present study was to explore the use of the TN-1002RD metal-oxide-semiconductor field effect transistor (MOSFET) dosimeter for measuring tissue depth dose at diagnostic photon energies in both homogeneous and heterogeneous tissue-equivalent materials. Three cylindrical phantoms were constructed and utilized as a prelude to more complex measurements within tomographic physical phantoms of pediatric patients. Each cylindrical phantom was constructed as a stack of seven 5-cm-diameter and 1-cm-thick discs of materials radiographically representative of either soft tissue (S), bone (B), or lung tissue (L) at diagnostic photon energies. In addition to a homogeneous phantom of soft tissue (SSSSSSS), two heterogeneous phantoms were constructed: SSBBSSS and SBLLBSS. MOSFET dosimeters were then positioned at the interface of each disc, and the phantoms were then irradiated at 66 kVp and 200 mAs. Measured values of absorbed dose at depth were then compared to predicated values of point tissue dose as determined via Monte Carlo radiation transport modeling. At depths exceeding 2 cm, experimental results matched the computed values of dose with high accuracy regardless of the dosimeter orientation (epoxy bubble facing toward or away from the x-ray beam). Discrepancies were noted, however, between measured and calculated point doses near the surface of the phantom (surface to 2 cm depth) when the dosimeters were oriented with the epoxy bubble facing the x-ray beam. These discrepancies were largely eliminated when the dosimeters were placed with the flat side facing the x-ray beam. It is therefore recommended that the MOSFET dosimeters be oriented with their flat sides facing the beam when they are used at shallow depths or on the surface of either phantoms or patients.

Child↗

A review of US anthropometric reference data (1971-2000) with comparisons to both stylized and tomographic anatomic models.

Two classes of anatomic models currently exist for use in both radiation protection and radiation dose reconstruction: stylized mathematical models and tomographic voxel models. The former utilize 3D surface equations to represent internal organ structure and external body shape, while the latter are based on segmented CT or MR images of a single individual. While tomographic models are clearly more anthropomorphic than stylized models, a given model's characterization as being anthropometric is dependent upon the reference human to which the model is compared. In the present study, data on total body mass, standing/sitting heights and body mass index are collected and reviewed for the US population covering the time interval from 1971 to 2000. These same anthropometric parameters are then assembled for the ORNL series of stylized models, the GSF series of tomographic models (Golem, Helga, Donna, etc), the adult male Zubal tomographic model and the UF newborn tomographic model. The stylized ORNL models of the adult male and female are found to be fairly representative of present-day average US males and females, respectively, in terms of both standing and sitting heights for ages between 20 and 60-80 years. While the ORNL adult male model provides a reasonably close match to the total body mass of the average US 21-year-old male (within approximately 5%), present-day 40-year-old males have an average total body mass that is approximately 16% higher. For radiation protection purposes, the use of the larger 73.7 kg adult ORNL stylized hermaphrodite model provides a much closer representation of average present-day US females at ages ranging from 20 to 70 years. In terms of the adult tomographic models from the GSF series, only Donna (40-year-old F) closely matches her age-matched US counterpart in terms of average body mass. Regarding standing heights, the better matches to US age-correlated averages belong to Irene (32-year-old F) for the females and Golem (38-year-old M) for the males. Both Helga (27-year-old F) and Donna, however, provide good matches to average US sitting heights for adult females, while Golem and Otoko (male of unknown age) yield sitting heights that are slightly below US adult male averages. Finally, Helga is seen as the only GSF tomographic female model that yields a body mass index in line with her average US female counterpart at age 26. In terms of dose reconstruction activities, however, all current tomographic voxel models are valuable assets in attempting to cover the broad distribution of individual anthropometric parameters representative of the current US population. It is highly recommended that similar attempts to create a broad library of tomographic models be initiated in the United States and elsewhere to complement and extend the limited number of tomographic models presently available for these efforts.

Adult↗

A hyperboliod representation of the bone-marrow interface within 3D NMR images of trabecular bone: applications to skeletal dosimetry.

Recent advances in physical models of skeletal dosimetry utilize high-resolution NMR microscopy images of trabecular bone. These images are coupled to radiation transport codes to assess energy deposition within active bone marrow irradiated by bone- or marrow-incorporated radionuclides. Recent studies have demonstrated that the rectangular shape of image voxels is responsible for cross-region (bone-to-marrow) absorbed fraction errors of up to 50% for very low-energy electrons (<50 keV). In this study, a new hyperboloid adaptation of the marching cube (MC) image-visualization algorithm is implemented within 3D digital images of trabecular bone to better define the bone-marrow interface, and thus reduce voxel effects in the assessment of cross-region absorbed fractions. To test the method, a mathematical sample of trabecular bone was constructed, composed of a random distribution of spherical marrow cavities, and subsequently coupled to the EGSnrc radiation code to generate reference values for the energy deposition in marrow or bone. Next, digital images of the bone model were constructed over a range of simulated image resolutions, and coupled to EGSnrc using the hyperboloid MC (HMC) algorithm. For the radionuclides 33P, 117mSn, 131I and 153Sm, values of S(marrow<--bone) estimated using voxel models of trabecular bone were shown to have relative errors of 10%, 9%, <1% and <1% at a voxel size of 150 microm. At a voxel size of 60 microm, these errors were 6%, 5%, <1% and <1%, respectively. When the HMC model was applied during particle transport, the relative errors on S(marrow<--bone) for these same radionuclides were reduced to 7%, 6%, <1% and <1% at a voxel size of 150 microm, and to 2%, 2%, <1% and <1% at a voxel size of 60 microm. The technique was also applied to a real NMR image of human trabecular bone with a similar demonstration of reductions in dosimetry errors.

Algorithms↗

A comparison of newborn stylized and tomographic models for dose assessment in paediatric radiology.

Establishment of organ doses from diagnostic and interventional examinations is a key component to quantifying the radiation risks from medical exposures and for formulating corresponding dose-reduction strategies. Radiation transport models of human anatomy provide a convenient method for simulating radiological examinations. At present, two classes of models exist: stylized mathematical models and tomographic voxel models. In the present study, organ dose comparisons are made for projection radiographs of both a stylized and a tomographic model of the newborn patient. Sixteen separate radiographs were simulated for each model at x-ray technique factors typical of newborn examinations: chest, abdomen, thorax and head views in the AP, PA, left LAT and right LAT projection orientation. For AP and PA radiographs of the torso (chest, abdomen and thorax views), the effective dose assessed for the tomographic model exceeds that for the stylized model with per cent differences ranging from 19% (AP abdominal view) to 43% AP chest view. In contrast, the effective dose for the stylized model exceeds that for the tomographic model for all eight lateral views including those of the head, with per cent differences ranging from 9% (LLAT chest view) to 51% (RLAT thorax view). While organ positioning differences do exist between the models, a major factor contributing to differences in effective dose is the models' exterior trunk shape. In the tomographic model, a more elliptical shape is seen thus providing for less tissue shielding for internal organs in the AP and PA directions, with corresponding increased tissue shielding in the lateral directions. This observation is opposite of that seen in comparisons of stylized and tomographic models of the adult.

Computer Simulation↗

Interactions with 3D isotropic and homogeneous radiation fields: a Monte Carlo simulation algorithm.

Monte Carlo techniques have become important tools for many biomedical applications. Many of these involve simulations of radiation fields that rely on the isotropy and homogeneity of the radiation source. The current study proposes a general algorithm to simulate such a radiation field around a fixed object. The idea is to surround the object with a sphere and to limit the source of radiation to the surface of that sphere. To insure the isotropy of the radiation source, each point on the sphere surface as seen from the object defines a direction at which a unidirectional field of particles is created. The combination of all unidirectional fields approaching from all points on the source sphere creates the effect of an isotropic and homogeneous radiation source. The algorithm is first presented without mathematical detail. Next, the expressions for the position and direction of the particles that compose the field are derived using analytical geometry. The radius of the source sphere is the only parameter needed for this algorithm. The randomness of each particle is simulated by the choice of four random numbers. Two algorithms using these analytical results are proposed, and an example of a C program is given for each. Both algorithms can be easily adapted to any situation that involves the Monte Carlo simulation of radiation interactions of a fixed object immersed within an isotropic and homogeneous radiation field.

Algorithms↗

Individual variations in mucosa and total wall thickness in the stomach and rectum assessed via endoscopic ultrasound.

Endoscopic ultrasound is a unique tool to acquire in vivo data on alimentary tract wall thicknesses of sufficient resolution needed in radiation dosimetry studies. Through their different echo texture and intensity, five layers of differing echo patterns for superficial mucosa, deep mucosa, submucosa, muscularis externa and serosa/adventitia exist within the walls of organs composing the alimentary tract. In this study, retrospective image analyses of patient video data were made for ten examinations of the stomach and eight examinations of the rectum covering a range of patient ages. Thicknesses for stomach mucosa ranged from 1030 +/- 130 microm to 1640 +/- 80 microm (total stomach wall thicknesses from 2.80 +/- 0.12 to 4.23 +/- 0.03 mm). Measurements made for the rectal images revealed rectal mucosal thicknesses from 660 +/- 50 microm to 1130 +/- 250 microm (total rectal wall thicknesses from 2.28 +/- 0.05 to 3.55 +/- 0.43 mm). The mucosa accounted for approximately 32 +/- 7% and approximately 32 +/- 8% of the total thickness of the stomach and rectal wall, respectively. These values can thus be utilized to investigate uncertainties in alimentary tract dosimetry that are based upon fixed reference individual definitions of organ wall structure.

Adult↗

Tissue-equivalent materials for construction of tomographic dosimetry phantoms in pediatric radiology.

Tissue equivalent materials have a variety of uses, including routine quality assurance and quality control in both diagnostic and therapeutic physics. They are frequently used in a research capacity to measure doses delivered to patients undergoing various therapeutic procedures. However, very few tissue equivalent materials have been developed for research use at the low photon energies encountered in diagnostic radiology. In this paper, we present a series of tissue-equivalent (TE) materials designed to radiographically mimic human tissue at diagnostic photon energies. These tissue equivalent materials include STES-NB (newborn soft tissue substitute), BTES-NB (newborn bone tissue substitute), LTES (newborn as well as a child/adult lung tissue substitute), STES (child/adult soft tissue substitute), and BTES (child/adult bone tissue substitute). In all cases, targeted reference elemental compositions are taken from those specified in the ORNL stylized computational model series. For each material, reference values of mass density, mass attenuation coefficients (10-150 keV), and mass energy-absorption coefficients (10-150 keV) were matched as closely as permitted by material selection and manufacturing constraints. Values of mu/rho and mu(en)/rho for the newborn TE materials are noted to have maximum deviations from their ORNL reference values of from 0 to -3% and from +2% to -3%, respectively, over the diagnostic energy range 10-150 keV. For the child/adult TE materials, these same maximal deviations of mu/rho and mu(en)/rho are from +1.5% to -3% and from +3% to -3%, respectively. Simple calculations of x-ray fluence attenuation under narrow-beam geometry using a 66 kVp spectrum typical of newborn CR radiographs indicate that the tissue-equivalent materials presented here yield estimates of absorbed dose at depth to within 3.6% for STES-NB, 3.2% for BTES-NB, and 1.2% for LTES of the doses assigned to reference newborn soft, bone, and lung tissue, respectively.

Adult↗

Creation of two tomographic voxel models of paediatric patients in the first year of life.

Tomographic computational models, based on regional segmentation of CT or MRI medical images, have increasingly been proposed as replacements for current stylized mathematical models of human anatomy used in radiation dosimetry studies. While much effort has been devoted towards the creation of adult models, few research studies have been initiated to address the need for models supporting paediatric radiology dosimetry. In this study, two tomographic models were created using a combination of automatic and manual segmentation via a program created in-house using IDL version 5.5. The first model is of a normal 6 day female newborn, and consists of a 512 x 512 x 485 data array. The CT slices of this model were obtained every 1 mm, and 66 different anatomic regions were defined. The second model is of a patient developmentally equivalent to a 2 month male, and was saved as a 512 x 512 x 438 data array. This subject had severe tissue oedema within the gut, kidneys, liver and spleen. The model is thus considered representative of a critically ill child, from a patient subpopulation expected to receive a larger than normal number of diagnostic x-ray exams. The voxel volumes for the two models are 0.35 mm3 and 0.30 mm3, respectively, thus making these models the most detailed in existence for paediatric dosimetry applications. Ratios of organ masses for the UF newborn model to those within the reference ORNL/MIRD model range from highs of 1.2 to 1.7 for the oesophagus and small intestine/colon, respectively, to lows of 0.18 to 0.27 for the mandible and humeri, respectively. For the UF 2 month model, ratios of organ masses in the UF model to those in the 8 week GSF BABY model ranged from highs of 3.7 to 5.2 for the clavicles and spleen, respectively, to lows of 0.2 to 0.3 for the adrenals and scapulae, respectively.

Anatomy, Cross-Sectional↗

Voxel effects within digital images of trabecular bone and their consequences on chord-length distribution measurements.

Chord-length distributions through the trabecular regions of the skeleton have been investigated since the early 1960s. These distributions have become important features for bone marrow dosimetry; as such, current models rely on the accuracy of their measurements. Recent techniques utilize nuclear magnetic resonance (NMR) microscopy to acquire 3D images of trabecular bone that are then used to measure 3D chord-length distributions by Monte Carlo methods. Previous studies have shown that two voxel effects largely affect the acquisition of these distributions within digital images. One is particularly pertinent as it dramatically changes the shape of the distribution and reduces its mean. An attempt was made to reduce this undesirable effect and good results were obtained for a single-sphere model using minimum acceptable chord (MAC) methods (Jokisch et al 2001 Med. Phys. 28 1493-504). The goal of the present work is to extend the study of these methods to more general models in order to better quantify their consequences. First, a mathematical model of a trabecular bone sample was used to test the usefulness of the MAC methods. The results showed that these methods were not efficient for this simulated bone model. These methods were further tested on a single voxelized sphere over a large range of voxel sizes. The results showed that the MAC methods are voxel-size dependent and overestimate the mean chord length for typical resolutions used with NMR microscopy. The study further suggests that bone and marrow chord-length distributions currently utilized in skeletal dosimetry models are most likely affected by voxel effects that yield values of mean chord length lower than their true values.

Bone Marrow↗

Evolution and status of bone and marrow dose models.

Investigations at the University of Leeds under the direction of F.W. Spiers in the early 1960s through the late 1970s established the first comprehensive assessment of marrow dose conversion factors (DCFs) for beta-emitting radionuclides within the volume or on the surface of trabecular bone. These DCFs were subsequently used in deriving radionuclide S values for skeletal tissues published in MIRD Pamphlet No. 11. Eckerman re-evaluated this work and extended the methods of Spiers to radionuclides within the marrow to provide DCFs for fifteen skeletal regions in computational models representing individuals of six different ages. These results were used in the MIRDOSE3 software. Bouchet et al. used updated information on regional bone and marrow masses, as well as 3D electron transport techniques, to derive radionuclide S values in skeletal regions of the adult. Although these two efforts are similar in most regards, the models differ in three respects in: (1) the definition of the red marrow region, (2) the definition of a surface source of activity, and (3) the assumption applied in transporting electrons through the trabecular endosteum. In this study, a review of chord-based skeletal models is given, followed by a description of the differences in the Eckerman and Bouchet et al. transport models. Finally, new data from NMR microscopy and radiation transport in trabecular bone is applied to address item (1) above. Dose conversion factors from MIRD 11, the Eckerman model, the Bouchet et al. model, and a revised model are compared for several radionuclides important to internal emitter therapy.

Animals↗

Skeletal dosimetry via NMR microscopy: investigations of sample reproducibility and signal source.

Nuclear magnetic resonance microscopy has been used for several years as a means of quantifying the 3D microarchitecture of the cancellous regions of the skeleton. These studies were originally undertaken for the purpose of developing non-invasive techniques for the early detection of osteoporosis and other bone structural changes. Recently, nuclear magnetic resonance microscopy has also been used to acquire this same 3D data for the purpose of both (1) generating chord length data across bone trabeculae and marrow cavities and (2) generating 3D images for direct coupling to Monte Carlo radiation transport codes. In both cases, one is interested in the reproducibility of the dosimetric data obtained from nuclear magnetic resonance microscopy. In the first of two studies, a trabecular bone sample from the femoral head of a 51-y-old male cadaver was subjected to repeated image acquisition, image processing, image coupling, and radiation transport simulations. The resulting absorbed fractions at high electron energies (4 MeV) were shown to vary less than 4% among four different imaging sessions of the same sample. In a separate study, two femoral head samples were imaged under differing conditions of the NMR signal source. In the first case, the samples were imaged with intact marrow. These samples were then subjected to marrow digestion and immersed in Gd-doped water, which then filled the marrow cavities. Energy-dependent absorbed fraction profiles for both the marrow-intact and marrow-free samples showed essentially equivalent results. These studies thus provide encouragement that skeletal dosimetry models of improved patient specificity can be achieved via NMR microscopy in vivo.

Bone and Bones↗

Site-specific variability in trabecular bone dosimetry: considerations of energy loss to cortical bone.

With continual advances in radionuclide therapies, increasing emphasis is being placed on improving the patient specificity of dose estimates to marrow tissues. While much work has been focused on determining patient-specific assessments of radionuclide uptake in the skeleton, few studies have been initiated to explore the individual variability of absorbed fraction data for electron and beta-particle sources in various skeletal sites. The most recent values of radionuclide S values used in clinical medicine continue to utilize a formalism in which electrons are transported under a trabecular bone geometry of infinite extent. No provisions are thus made for the fraction of energy lost to the cortical bone cortex of the skeletal site and its surrounding tissues. In the present study, NMR microscopy was performed on trabecular bone samples taken from the femoral head and humeral proximal epiphysis of three subjects: a 51-year male, an 82-year female, and an 86-year female. Following image segmentation and coupling to EGS4, electrons were transported within macrostructural models of the various skeletal sites that explicitly include the spatial extent of the spongiosa, as well as the thickness of the surrounding cortical bone. These energy-dependent profiles of absorbed fractions to marrow tissues were then compared to transport simulations made within an infinite region of spongiosa. Ratios of mean absorbed fraction, as weighted by the beta energy spectra, under both transport methodologies were then assembled for the radionuclides 32P and 90Y. These ratios indicate that corrections to existing radionuclide S values for 32P can vary by as much as 5% for the male, 6% for the 82-year female, and 8% for the 86-year female. For the higher-energy beta spectrum of 90Y, these same corrections can reach 8%, 10%, and 11%, respectively.

Aged↗

Surface area overestimation within three-dimensional digital images and its consequence for skeletal dosimetry.

The most recent methods for trabecular bone dosimetry are based on Monte Carlo transport simulations within three-dimensional (3D) images of real human bone samples. Nuclear magnetic resonance and micro-computed tomography have been commonly used as imaging tools for studying trabecular microstructure. In order to evaluate the accuracy of these techniques for radiation dosimetry, a previous study was conducted that showed an overestimate in the absorbed fraction of energy for low-energy electrons emitted within the marrow space and irradiating the bone trabeculae. This problem was found to be related to an overestimate of the surface area of the true bone-marrow interface within the 3D digital images, and was identified as the surface-area effect. The goal of the present study is to better understand how this surface-area effect occurs in the case of single spheres representing individual marrow cavities within trabecular bone. First, a theoretical study was conducted which showed that voxelization of the spherical marrow cavity results in a 50% overestimation of the spherical surface area. Moreover, this overestimation cannot be reduced through a reduction in the voxel size (e.g., improved image resolution). Second, a series of single-sphere marrow cavity models was created with electron sources simulated within the sphere (marrow source) and outside the sphere (bone trabeculae source). The series of single-sphere models was then voxelized to represent 3D digital images of varying resolution. Transport calculations were made for both marrow and bone electron sources within these simulated images. The study showed that for low-energy electrons (<100 keV), the 50% overestimate of the bone-marrow interface surface area can lead to a 50% overestimate of the cross-absorbed fraction. It is concluded that while improved resolution will not reduce the surface area effects found within 3D image-based transport models, a tenfold improvement in current image resolution would compensate the associated errors in cross-region absorbed fractions for low-energy electron sources. Alternatively, other methods of defining the bone-marrow interface, such as with a polygonal isosurface, would provide improvements in dosimetry without the need for drastic reductions in image voxel size.

Biophysical Phenomena↗

Considerations of anthropometric, tissue volume, and tissue mass scaling for improved patient specificity of skeletal S values.

It is generally acknowledged that reference man (70 kg in mass and 170 cm in height) does not adequately represent the stature and physical dimensions of many patients undergoing radionuclide therapy, and thus scaling of radionuclide S values is required for patient specificity. For electron and beta sources uniformly distributed within internal organs, the mean dose from self-irradiation is noted to scale inversely with organ mass, provided no escape of electron energy occurs at the organ boundaries. In the skeleton, this same scaling approach is further assumed to be correct for marrow dosimetry; nevertheless, difficulties in quantitative assessments of marrow mass in specific skeletal regions of the patient make this approach difficult to implement clinically. Instead, scaling of marrow dose is achieved using various anthropometric parameters that presumably scale in the same proportion. In this study, recently developed three-dimensional macrostructural transport models of the femoral head and humeral epiphysis in three individuals (51-year male, 82-year female, and 86-year female) are used to test the abilities of different anthropometric parameters (total body mass, body surface area, etc.) to properly scale radionuclide S values from reference man models. The radionuclides considered are 33P, 177Lu, 153Sm, 186Re, 89Sr, 166Ho, 32P, 188Re, and 90Y localized in either the active marrow or endosteal tissues of the bone trabeculae. S value scaling is additionally conducted in which the 51-year male subject is assigned as the reference individual; scaling parameters are then expanded to include tissue volumes and masses for both active marrow and skeletal spongiosa. The study concludes that, while no single anthropometric parameter emerges as a consistent scaler of reference man S values, lean body mass is indicated as an optimal scaler when the reference S values are based on 3D transport techniques. Furthermore, very exact patient-specific scaling of radionuclide S values can be achieved if measurements of spongiosa volume and marrow volume fraction (high-resolution CT with image segmentation) are known in both the patient and the reference individual at skeletal sites for which dose estimates are sought. However, the study indicates that measurements of the spongiosa volume alone may be sufficient for reasonable patient-specific scaling of S values for the majority of radionuclides of interest in internal-emitter therapy.

Aged↗

Comparisons of point and average organ dose within an anthropomorphic physical phantom and a computational model of the newborn patient.

Pediatric radiographic examinations yield medical benefits and/or diagnostic information that must be balanced against potential risk from patient radiation exposure. Consequently, clinical tools for measuring internal organ dose are needed for medical risk assessment. In this study, a physical phantom and Monte Carlo simulation model of the newborn patient were developed based upon their stylized mathematical expressions (ORNL and MIRD model series). The physical phantom was constructed using tissue equivalent substitutes for soft tissue, lung, and skeleton. Twenty metal-oxide-semiconductor field effect transistor (MOSFET) dosimeters were then inserted at three-dimensional positions representing the centroids of organs assigned in the ICRP's definition of the effective dose. MOSFET-derived point estimates of organ dose were shown to be in reasonable agreement with Monte Carlo estimates for representative newborn head, chest, and abdomen radiographic exams. Ratios of average organ dose assessed via MCNP simulations to the MOSFET-derived point doses (point-to-organ dose scaling factors, SF(POD)) are tabulated for subsequent use in clinical irradiations of the newborn phantom/MOSFET system. Values of SF(POD) indicate that MOSFET measurements of point dose for in-field exposures need to be adjusted only to within 10% to report volume-averaged organ dose. Larger adjustments to point doses are noted for organs out-of-field. For walled organs, point estimates of organ dose at the content centroid are shown to underestimate the average wall dose when the organ is within the primary field: SF(POD) of 1.19 for the stomach (AP chest exam), and SF(POD) of 1.15 for the urinary bladder (AP abdomen exam).

Abdomen↗

Application of imaging-derived parameters to dosimetry of intravascular brachytherapy sources: perturbation effects of residual plaque burden.

The dosimetric effect of geometric and material heterogeneities on intravascular brachytherapy dose delivery has been studied recently. Residual plaque within the coronary vessel appears to have an impact on the uniform delivery of radiation dose to the arterial tissue. In this study, we have examined the effect of residual plaque burden and post-PCI (percutaneous coronary intervention) plaque configuration on the dose to the arterial wall from clinical intravascular brachytherapy beta-emitting sources containing 32P and 90Sr/90Y. Monte Carlo simulations using the MCNP4B code were performed for these catheter-based sources with residual plaque burden ranging between 25% and 50%. The residual plaque burden values were derived from post-PCI data provided in several recent clinical studies. Dose calculations were performed for three different values of plaque density (1.45 g cm(-3), 2.20 g cm(-3), and 3.1 g cm(-3)) and three different plaque morphologies for the same residual plaque burden. The dose perturbation factor (DPF), defined as the ratio of dose at 2 mm radial distance for a given case to the dose at the same radial distance in homogeneous water medium, was determined for each of the three different plaque densities. The range of DPF values was 0.81-1.01, 0.62-0.99, and 0.41-0.97 for different plaque densities for the 32P source. Corresponding DPF values for the 90Sr/90Y source were 0.90-1.01, 0.84-1.01, and 0.62-1.01. The results indicate the need for accurate assessment of post-PCI clinical measurements such as minimal lumen diameter and residual plaque burden and incorporation of these values into dose calculations.

Brachytherapy↗