PubMed Health⌕ Search

Biomedical subjects

W E Hennink

Publications and source records attributed to W E Hennink.

At least 19 recordsLinked to original sources

Removal of chloroform from biodegradable therapeutic microspheres by radiolysis.

Radioactive holmium-166 loaded poly(l-lactic acid) microspheres are promising systems for the treatment of liver malignancies. These microspheres are loaded with holmium acetylacetonate (HoAcAc) and prepared by a solvent evaporation method using chloroform. After preparation the microspheres (Ho-PLLA-MS) are activated by neutron irradiation in a nuclear reactor. It was observed that relatively large amounts of residual chloroform (1000-6000 ppm) remained in the microspheres before neutron irradiation. Since it is known that chloroform is susceptible for high-energy radiation, we investigated whether neutron and gamma irradiation could result in the removal of residual chloroform in HoAcAc-loaded and placebo PLLA-MS by radiolysis. To investigate this, microspheres with relatively high and low amounts of residual chloroform were subjected to irradiation. The effect of irradiation on the residual chloroform levels as well as other microsphere characteristics (morphology, size, crystallinity, molecular weight of PLLA and degradation products) were evaluated. No chloroform in the microspheres could be detected after neutron irradiation. This was also seen for gamma irradiation at a dose of 200 kGy phosgene, which can be formed as the result of radiolysis of chloroform, was not detected with gas chromatography-mass spectrometry (GC-MS). A precipitation titration showed that radiolysis of chloroform resulted in the formation of chloride. Gel permeation chromatography and differential scanning calorimetry showed a decrease in molecular weight of PLLA and crystallinity, respectively. However, no differences were observed between irradiated microsphere samples with high and low initial amounts of chloroform. In conclusion, this study demonstrates that neutron and gamma irradiation results in the removal of residual chloroform in PLLA-microspheres.

Biodegradation, Environmental↗

Production of GMP-grade radioactive holmium loaded poly(L-lactic acid) microspheres for clinical application.

Radioactive holmium-166 loaded poly(L-lactic acid) microspheres are promising systems for the treatment of liver malignancies. The microspheres are loaded with holmium acetylacetonate (HoAcAc) and prepared by a solvent evaporation method. After preparation, the microspheres (Ho-PLLA-MS) are activated by neutron irradiation in a nuclear reactor. In this paper, the aspects of the production of a (relatively) large-scale GMP batch (4 g, suitable for treatment of 5-10 patients) of Ho-PLLA-MS are described. The critical steps of the Ho-PLLA-MS production process (sieving procedure, temperature control during evaporation and raw materials) were considered and the pharmaceutical quality of the microspheres was evaluated. The pharmaceutical characteristics (residual solvents, possible bacterial contaminations and endotoxins) of the produced Ho-PLLA-MS batches were in compliance with the requirements of the European Pharmacopoeia. Moreover, neutron irradiated Ho-PLLA-MS retained their morphological integrity and the holmium remained stably associated with the microspheres; it was observed that after 270h (10 times the half-life of Ho-166) only 0.3+/-0.1% of the loading was released from the microspheres in an aqueous solution. In conclusion, Ho-PLLA-MS which are produced as described in this paper, can be clinically applied, with respect to their pharmaceutical quality.

Brachytherapy↗

Static light scattering and small-angle neutron scattering study on aggregated recombinant gelatin in aqueous solution.

Recombinant gelatins are currently evaluated as new excipients for pharmaceutical formulations. They can differ from nonrecombinant gelatins because of intentional alteration of the amino acid sequence and specific properties of the expression systems used. This may affect their solution behavior. In the present work, aqueous solutions of a histidine-containing recombinant gelatin (RG-15-His) were analyzed. Dynamic light scattering (DLS) and loss of absorbance at 200 nm upon centrifugation indicated the formation of aggregates within 1 day upon sample preparation. Static light scattering (SLS) and small-angle neutron scattering (SANS) experiments showed that the aggregate's size was > or =300 nm, and that aggregates are composed of thin, rigid rods of 37 +/- 5 nm in length. The observed aggregation was not detectable by circular dichroism (CD), Fourier transform infrared spectroscopy (FTIR), and cryo transmission electron microscopy (cryo-TEM). SANS experiments, which are not frequently used in the pharmaceutical field, provided additional morphological information about the recombinant gelatin in solution. The results show that combining SLS and SANS is a broadly applicable, complementary approach for detecting aggregation of proteins and other biomolecules and for obtaining structural information about the aggregates.

Gelatin↗

An NLS peptide covalently linked to linear DNA does not enhance transfection efficiency of cationic polymer based gene delivery systems.

BACKGROUND: Transfection with non-viral gene delivery vectors, such as cationic polymers, generally results in low transgene expression in vivo. This is likely due to poor cytoplasmic transport and intra-nuclear DNA delivery. METHODS: In this study two strategies to improve nuclear import were investigated. Linear DNA constructs with or without an NLS peptide were prepared by PCR. Alternatively, linear DNA obtained by enzymatic cleavage followed by capping of both ends with DNA-hairpins was used. An NLS peptide was attached to one of the capped ends of the linear DNA. Both biodegradable (pDMAEAppz) and non-degradable polymers (PEI or pDMAEMA) were used to complex the DNA. Several cell types, dividing and non-dividing, were transfected with the linear DNA constructs containing a SV40-derived NLS peptide. Nuclear import of the DNA constructs was studied using digitonin-permeabilized cells. RESULTS: Linear DNA prepared by PCR proved not useful as it was degraded from the 3'end. Linear DNA capped with hairpins was more successful with regard to stability. However, Cells transfected with linear DNA constructs by electroporation or by using cationic polymers with linear DNA containing a NLS peptide, failed to show significantly higher luciferase expression levels when compared to cells transfected with plasmid DNA or linear DNA without an NLS peptide attached. No nuclear localization was observed in digitonin-permeabilized cells. CONCLUSION: Taken together, these data demonstrate that this nuclear localisation signal when attached to DNA is neither able to improve transfection efficiency of cationic polymers nor the nuclear import of the DNA constructs.

Active Transport, Cell Nucleus↗

Surface characteristics of holmium-loaded poly(L-lactic acid) microspheres.

Radioactive holmium-166-loaded poly(L-lactic acid) microspheres (Ho-PLLA-MS) are promising systems for the treatment of liver malignancies. The surface characteristics of Ho-PLLA-MS before and after both neutron and gamma irradiation were investigated in order to get insight into their suspending behaviour and to identify suitable surfactants for clinical application of these systems. X-ray photoelectron spectroscopy (XPS) and scanning electron microscopy (SEM) were used for surface characterization. The residual amounts of poly(vinyl alcohol) (PVA) of the microspheres, which was used as an emulsifier during the solvent evaporation process, were determined using a colorimetric iodine-borate method and the wettability of microspheres and PLLA films with and without holmium (Ho) loading was tested using suspending experiments and contact angle measurements. XPS showed that the surface of Ho-PLLA-MS mainly consisted of PLLA, less than 10% of the surface was covered with PVA after several washing and sieving steps. A colorimetric assay showed that the microspheres contained 0.2-0.3% (w/w) PVA. Combined with XPS data, this assay demonstrates that the PVA is likely dissolved in the core of the microspheres. XPS analysis also showed that after neutron irradiation, some holmium appeared on the surface. Moreover, Ho-loaded PLLA films had a much higher contact angle (85 degrees) than non-loaded films (70 degrees). Therefore, the Ho on the surface of neutron-irradiated Ho-PLLA-MS is probably the reason for their poor suspending behaviour in saline. No surface changes were seen with XPS after gamma irradiation. Based on their surface characteristics, a pharmaceutically acceptable solvent (1% Pluronic F68 or F127 in 10% ethanol) was formulated with which a homogeneous suspension of radioactive Ho-PLLA-MS could be easily obtained, making these systems feasible for further clinical evaluation.

Holmium↗

Lanthanide bearing microparticulate systems for multi-modality imaging and targeted therapy of cancer.

The rapid developments of high-resolution imaging techniques are offering unique possibilities for the guidance and follow up of recently developed sophisticated anticancer therapies. Advanced biodegradable drug delivery systems, e.g. based on liposomes and polymeric nanoparticles or microparticles, are very effective tools to carry these anticancer agents to their site of action. Elements from the group of lanthanides have very interesting physical characteristics for imaging applications and are the ideal candidates to be co-loaded either in their non-radioactive or radioactive form into these advanced drug delivery systems because of the following reasons: Firstly, they can be used both as magnetic resonance imaging (MRI) and computed tomography (CT) contrast agents and for single photon emission computed tomography (SPECT). Secondly, they can be used for radionuclide therapies which, importantly, can be monitored with SPECT, CT, and MRI. Thirdly, they have a relatively low toxicity, especially when they are complexed to ligands. This review gives a survey of the currently developed lanthanide-loaded microparticulate systems that are under investigation for cancer imaging and/or cancer therapy.

Animals↗

Effect of polymerization conditions on the network properties of dex-HEMA microspheres and macro-hydrogels.

Dextran-hydroxy-ethyl-methacrylate (dex-HEMA) hydrogels in the form of microspheres are an attractive system for the controlled delivery of protein drugs. In this work, the microspheres were prepared by a water-in-water emulsion polymerization process. The polymerization reaction was initiated by potassium peroxodisulfate (KPS) and catalyzed by N,N,N',N'-tetramethylethylenediamine (TEMED). The effect of the initiator concentration, reaction temperature and pH on the mechanical and network properties of the microspheres were investigated. The size and size distribution of the microspheres, equilibrium water content, and methacrylate conversion were also determined. The mechanical properties of single microspheres were measured by a micromanipulation technique and the rheological characteristics of the same material in the form of macroscopic hydrogel slabs were determined by a controlled stress rheometer. The results showed that the Young's moduli of the microspheres and of macroscopic slabs measured by these two methods were in good agreement. Higher KPS initiator concentrations resulted in a more rapid polymerization with a shorter gelation and lag time, and a higher Young's modulus of the gels. An increase in temperature also resulted in a more rapid polymerization with a shorter gelation and lag time. However, the Young's modulus of the gels decreased with an increase in polymerization temperature. The pH had no significant effect on the mechanical properties of the microspheres. This study demonstrates that the network properties of dex-HEMA hydrogels can be tailored by the polymerization conditions, which opens the possibility to modulate the release rate of entrapped compounds.

Chemistry, Pharmaceutical↗

Biodegradable dextran hydrogels crosslinked by stereocomplex formation for the controlled release of pharmaceutical proteins.

Hydrogels are based on hydrophilic polymers, which are crosslinked to prevent dissolution in water. Because hydrogels can contain large amounts of water, they are interesting devices for the delivery of proteins. In this contribution a biodegradable dextran hydrogel is described which is based on physical interactions and is particularly suitable for the controlled delivery of pharmaceutically active proteins. The unique feature of our system is that the preparation of the hydrogels takes place in an all-aqueous solution, by which the use of organic solvents is avoided. Furthermore, chemical crosslinking agents are not needed to create the hydrogels, since crosslinking is established physically by stereocomplex formation between enantiomeric oligomeric lactic acid chains. The hydrogel is simply obtained after mixing aqueous solutions of dextran(l)-lactate and dextran(d)-lactate. In this contribution, the formation of the hydrogels as well as their protein release properties and degradation behavior are discussed.

Biocompatible Materials↗

Steric stabilization of poly(2-(dimethylamino)ethyl methacrylate)-based polyplexes mediates prolonged circulation and tumor targeting in mice.

BACKGROUND: Efficient tumor targeting of polymeric gene transfer systems (polyplexes) represents a major challenge. To establish tumor targeting after intravenous (IV) administration, the circulation lifetime of these systems should be sufficiently long. Since naked polyplexes are rapidly eliminated from the circulation after IV adminstration, strategies have to be developed to improve their pharmacokinetics. METHODS: Complexes of plasmid DNA and poly(2-(dimethylamino)ethyl methacrylate) (pDMAEMA)-graft-PEG or AB di-block copolymers of pDMAEMA and PEG, as well as PEGylated complexes prepared via PEGylation of preformed complexes (postPEGylation), were evaluated for their physicochemical properties (size and charge) their interactions with blood constituents and transfection activity in vitro. The pharmacokinetics and biodistribution of PEG-polyplexes were studied in mice after IV administration. The degree of accumulation in two subcutaneous (SC) mouse tumors after IV administration was evaluated for the system with the longest circulation time. RESULTS: It is shown that the surface charge of the pDMAEMA-polyplexes was effectively shielded by two PEGylation methods (i.e. the use of pDMAEMA-graft-PEG polymers and postPEGylation). The shielding effect was the highest for the postPEGylation method with PEG(20000), yielding polyplexes that hardly show interactions with blood components (i.e. albumin and erythrocytes) and show substantially prolonged circulation time in mice after IV administration. The superior colloidal stability and circulation kinetics of the postPEGylated polyplexes translated into tumor accumulation which amounted to about 3.5% of the injected dose per gram tumor tissue in a SC Neuro2A tumor model and to about 4.2% of the injected dose per gram tumor tissue in a SC C26 tumor model. CONCLUSIONS: This study shows that postPEGylation of pDMAEMA-based polyplexes is the most attractive method to prepare polyplexes with long circulating properties. Tumor targeting capacity after intravenous administration was demonstrated in two subcutaneous tumor models.

Adenocarcinoma↗

The effect of the processing and formulation parameters on the size of nanoparticles based on block copolymers of poly(ethylene glycol) and poly(N-isopropylacrylamide) with and without hydrolytically sensitive groups.

Block copolymers of poly(ethylene glycol) (PEG) as a hydrophilic block and N-isopropylacrylamide (PNIPAAm) or poly (NIPAAm-co-N-(2-hydroxypropyl) methacrylamide-dilactate) (poly(NIPAAm-co-HPMAm-dilactate)) as a thermosensitive block, are able to self-assemble in water into nanoparticles above the cloud point (CP) of the thermosensitive block. The influence of processing and the formulation parameters on the size of the nanoparticles was studied using dynamic light scattering. PNIPAAm-b-PEG 2000 polymers were not suitable for the formation of small and stable particles. Block copolymers with PEG 5000 and 10000 formed relatively small and stable particles in aqueous solutions at temperatures above the CP of the thermosensitive block. Their size decreased with increasing molecular weight of the thermosensitive block, decreasing polymer concentration and using water instead of phosphate buffered saline as solvent. Extrusion and ultrasonication were inefficient methods to size down the polymeric nanoparticles. The heating rate of the polymer solutions was a dominant factor for the size of the nanoparticles. When an aqueous polymer solution was slowly heated through the CP, rather large particles (> or = 200 nm) were formed. Regardless the polymer composition, small nanoparticles (50-70 nm) with a narrow size distribution were formed, when a small volume of an aqueous polymer solution below the CP was added to a large volume of heated water. In this way the thermosensitive block copolymers rapidly pass their CP ('heat shock' procedure), resulting in small and stable nanoparticles.

Acrylic Resins↗

IL-2 loaded dextran microspheres with attractive histocompatibility properties for local IL-2 cancer therapy.

Biodegradable dextran microspheres (MS) were developed as a slow-release system for interleukin-2 (IL-2) to apply them for local IL-2 therapy of cancer. We describe the tissue reactions induced by these MS without or with IL-2 in rats. Dextran MS stain bright red-purple with the periodic acid Schiff (PAS), visualising the exact spot of IL-2 release and its relation to the histological reaction pattern. Subcutaneously injected MS always form a well-circumscribed deposit. In the first 2 days there is a PMN inflammation within the MS-deposit, but the surroundings show only a scanty inflammatory reaction. The PMN reaction is replaced by an abundant macrophage reaction in particular in the MS-deposit. At day 21 a fibrous capsule of about 50 mum surrounds the deposit. The effect of IL-2 administered in its free form is mainly vascular, with vascular dilatation, vascular leakage and oedema. It is remarkable that lymphocytes are present in the injection area already at day 2. When IL-2 releasing MS were used, the various reactions induced by IL-2 and MS were amplified leading to local necrosis. We conclude that neither placebo MS nor IL-2 leads to necrosis after subcutaneous injection in rats. In contrast, when IL-2 was released from MS, then massive necrosis was induced. This might be due to increased phagocytosis or changes in the micro-niche due to the release of humoral factors by the infiltrating cells. This is probably fortuitous for local IL-2 therapy of cancer, as massive necrosis of tumour cells can be expected to lead to an increased antitumour reaction.

Animals↗

Water-soluble biodegradable cationic polyphosphazenes for gene delivery.

Polyphosphazenes bearing cationic moieties were synthesized from poly(dichloro)phosphazene, which in turn was obtained by thermal polymerization of hexachlorocyclotriphosphazene in 1,2,4-trichlorobenzene. Next, either 2-dimethylaminoethanol (DMAE) or 2-dimethylaminoethylamine (DMAEA) side groups were introduced by a substitution reaction. The polymers were purified by dialysis against water and tetrahydrofuran, lyophilized and evaluated as polymeric transfectants. The polyphosphazenes were able to bind plasmid DNA yielding positively charged particles (polyplexes) with a size around 80 nm at a polymer/DNA ratio of 3:1 (w/w). The polyphosphazene-based polyplexes were able to transfect COS-7 cells in vitro with an efficiency comparable to a well-known polymeric transfectant [poly(2-dimethylaminoethyl methacrylate), pDMAEMA]. The toxicity of both polyphosphazenes was lower than pDMAEMA. The transfection efficiency for the poly(DMAE)phosphazene-based polyplexes was about threefold higher in the absence of serum than in the presence of 5.0% fetal bovine serum. This is probably caused by unfavorable interactions of the polyplexes with serum proteins. In contrast, the poly(DMAEA)phosphazene-based polyplexes showed a threefold lower transfection activity in the absence of serum. For this system, serum proteins likely masked the toxicity of the polyplexes, as shown by the XTT cell viability assay and confocal laser scanning microscopy studies. Preliminary degradation studies indicate that the polymers were indeed degradable. The half-life at pH 7.5 and 37 degrees C was around 7 days for poly(DMAE)phosphazenes and 24 days for poly(DMAEA)phosphazenes. This study shows that polyphosphazenes are a suitable and promising new class of biodegradable polymeric carriers for gene delivery.

Animals↗

Preparation and characterization of folate-targeted pEG-coated pDMAEMA-based polyplexes.

A folate-poly(ethylene glycol) conjugate capable of covalent coupling to primary amines present at the surface of polyplexes was developed. Coating of poly(dimethylaminomethyl methacrylate (pDMAEMA)-based polyplexes with this folate-pEG conjugate led to a sharp decrease of the zeta-potential, and a small increase in particle size. The size of the particles in isotonic medium did not change markedly in time demonstrating that rather stable particles were formed. The in vitro cellular toxicity of the pEGylated polyplexes with and without folate ligands was lowered considerably compared to uncoated polyplexes. The toxicity observed for the targeted pEGylated polyplexes was slightly higher than that of corresponding untargeted polyplexes, which might indicate an increased cellular association of targeted polyplexes. Transfection of OVCAR-3 cells in vitro was markedly increased compared to untargeted pEGylated polyplexes, suggesting targeted gene delivery.

Drug Delivery Systems↗

Release of recombinant human interleukin-2 from dextran-based hydrogels.

In this study, the release of recombinant human interleukin-2 (rhIL-2) from methacrylated dextran (dex-MA) and (lactate-)hydroxyethyl methacrylated dextran (dex-(lactate-)HEMA) hydrogels with varying crosslink density was investigated. Hydrogels derived from dex-MA are stable under physiological conditions (pH 7 and 37 degrees C), whereas dex-HEMA and dex-lactate-HEMA hydrogels degrade due to the presence of hydrolytically sensitive esters in the crosslinks of the gels. The protein release profiles both the non-degradable and degradable dextran-based hydrogels showed that with increasing crosslink density of the gel, the release of rhIL-2 decreases. From dex-MA hydrogels with an initial water content above 70%, the rhIL-2 release followed Fickian diffusion, whereas from gels with an initial water content of 70% or lower the protein was fully entrapped in the hydrogel meshes. In contrast with non-degradable dex-MA hydrogels, degradable dex-lactate-HEMA gels with comparable network characteristics (degree of methacrylate substitution and initial water content) showed an almost zero-order, degradation controlled release of rhIL-2 in a time period of 5-15 days. This paper demonstrates that the release of rhIL-2 from non-degradable dex-MA and degradable dex-lactate-HEMA gels can be modulated by the crosslink density and/or the degradation characteristics of the hydrogel. Importantly, rhIL-2 was mainly released as monomer from the hydrogels and with good retention of its biological activity.

Dextrans↗

Novel crosslinking methods to design hydrogels.

Hydrogels are presently under investigation as matrices for the controlled release of bioactive molecules, in particular pharmaceutical proteins, and for the encapsulation of living cells. For these applications, it is often required that the gels degrade under physiological conditions. This means that the originally three-dimensional structure has to disintegrate preferably in harmless products to ensure a good biocompatibility of the hydrogel. In this overview, different chemical and physical crosslinking methods used for the design of biodegradable hydrogels are summarized and discussed. Chemical crosslinking is a highly versatile method to create hydrogels with good mechanical stability. However, the crosslinking agents used are often toxic compounds, which have been extracted from the gels before they can be applied. Moreover, crosslinking agents can give unwanted reactions with the bioactive substances present in the hydrogel matrix. Such adverse effects are avoided with the use of physically crosslinked gels.

Biocompatible Materials↗