PubMed Health⌕ Search

Biomedical subjects

W Elias

Publications and source records attributed to W Elias.

17 recordsLinked to original sources

[MS registry in Germany--design and first results of the pilot phase].

In the summer of 2001, a nationwide epidemiological multiple sclerosis (MS) register was initiated under the auspices of the German MS Society (DMSG). This project aimed at collecting epidemiological data on the number of patients with MS, course of the disease, and their social situation in Germany. During the 2-year pilot phase, five MS centers with various regional differences and treatment methods participated, leading to a representative selection of patients. In December 2003, standardised data sets of 3,458 MS patients were available for evaluation. After examining the quality of the data, 3,223 sets remained for further analysis. The demographics were similar to those obtained from other epidemiological studies: 72% of the patients were female, mean age was 42.9+/-11.2 years, mean disease duration 12.6+/-8.7 years, and 64% suffered from the relapsing-remitting form of the disease. The median EDSS was 3.0, and 69% of patients had an EDSS </=4.0. The great effect of this disorder was underscored by the fact that one third of the patients had prematurely retired due to MS. After successful completion of the pilot phase, the MS register will provide reliable data and thus serve as an important tool to improve the overall situation of MS patients in Germany.

Adult↗

Atrial natriuretic factor and pulmonary status in premature infants with respiratory distress syndrome: preliminary investigation.

We studied the correlation of atrial natriuretic factor (ANF) with lung compliance in a series of 16 premature infants with respiratory distress syndrome (RDS). The infants were followed during the first week of life by sequential Doppler echocardiography, lung compliance, and ANF measurements. Plasma ANF concentration varied between 38 and 2220 pg/mL; mean concentrations of 393 and 123 pg/mL with the ductus open and with it closed, respectively (P < 0.01). The arteriolar/alveolar oxygen-tension ratio showed an inverse correlation with the logarithm (In) of the ANF concentration (r = -0.55, P = 0.0002). Both mean airway pressure and In ANF showed an inverse correlation with the arteriolar/alveolar oxygen tension ratio (R = -0.77, F = 20.5 and 13.8, respectively). Plasma ANF was inversely correlated to lung compliance (r = -0.64, P < 0.0001). In infants with RDS, plasma ANF concentrations increase with the severity of respiratory distress. Because ANF increases endothelial permeability, in this preliminary investigation lead to the hypothesis that it may contribute to respiratory distress by causing extravasation of fluid from the pulmonary circulation in these patients.

Atrial Natriuretic Factor↗

Cine magnetic resonance imaging and color Doppler flow mapping displays of flow velocity, spatial acceleration, and jet formation: a comparative in vitro study.

To study the effects of flow acceleration and high-velocity jets on the display characteristics of cine magnetic resonance imaging compared with color Doppler flow mapping, a custom-designed in vitro flow model was developed. This model consisted of a funnel segment tapering to an orifice (0.78 cm2) that leads into a confined receiving chamber with a second, discrete orifice (0.78 cm2) at its distal end. Cine magnetic resonance images obtained at varying flow rates (1.5 to 27.2 L/min) demonstrated loss of signal intensity throughout the tapering zone of spatial acceleration and a small zone of more marked signal loss immediately proximal to the second orifice (always < 50% of the signal intensity within the tapering funnel zone) associated with more rapid spatial acceleration. A formed jet was imaged distal to the first orifice, and the turbulence area surrounding the laminar central jet core correlated well with flow rate (r = 0.98), as did the distance from the orifice to the subsequent onset of flow relaminarization (r = 0.96). A turbulent spray area was always seen distal to the second, discrete orifice. Comparative observations with color Doppler flow mapping and continuous wave Doppler demonstrated that signal intensity on cine magnetic resonance imaging is reduced by both spatial acceleration, and the high-velocity and turbulent jets associated with obstructive and regurgitant lesions. In vitro evaluation of cine magnetic resonance imaging allows comparative observations to be made about the flow characteristics of cine magnetic resonance imaging and color Doppler flow mapping and provides a more rational basis for the interpretation of cine magnetic resonance imaging in the clinical setting.

Blood Flow Velocity↗

Surgical management of major varicose veins of the lower limb using a pneumatic tourniquet.

A technique to facilitate ablation of varicose veins is described. We have tested this technique in 25 patients. A pneumatic tourniquet is place on the lower limb during operation for a maximum of 90 minutes. This technique allows the operative field to remain dry and clean, and the resulting bloodless field makes the operation easier and faster. Because the veins are empty, they are removed more easily and completely, even in cases of severe dermatitis or adhesion.

Air↗

Correlation of patent ductus arteriosus shunting with plasma atrial natriuretic factor concentration in preterm infants with respiratory distress syndrome.

The concentration of plasma atrial natriuretic factor (ANF) and the mechanism for its secretion were investigated in 17 preterm infants with respiratory distress. Their mean gestational age was 29 wk and wt 1250 g. The infants were followed during the first week of life by sequential Doppler ultrasound studies. Ductal openness versus closure and amount of ductal flow were correlated with plasma ANF concentrations. In a subset of 10 infants, sequential Doppler color flow mapping was used to quantify the ductal flow. During the first 72 h, plasma ANF was high, 361 pg/mL; it decreased to 96 pg/mL by the end of the 1st wk. The ANF level was significantly higher when the ductus was open than closed (393 versus 123 pg/mL, p less than 0.05). In patients with open ductus and bidirectional foramen ovale shunting (n = 3) ANF was 567 pg/mL and in those with left-to-right shunt 355 pg/mL (n 15, NS). The left atrial size, i.e. the left atrial to aortic root ratio, correlated with the amount of ductal shunting (r = 0.63, p less than 0.01) and with ANF concentration (r = 0.46, p less than 0.02). The correlation of ANF values and the magnitude of left-to-right ductal shunting assessed by color flow mapping was highly significant (r = 0.66, p less than 0.001). In these patients, the elevation of ANF is reflective of ductal flow.

Age Factors↗

Experimental ductus arteriosus: the relationships of atrial pressure, dilatation and flow with ANF secretion.

The design of the study was to determine whether an increased blood flow as seen in shunt lesions could serve as a stimulus for the secretion of atrial natriuretic factor (ANF). Since atrial pressure, flow, and dilatation are closely related, an experimental ductus arteriosus model was utilized, in which acute changes of flow are assumed not to dilate the left atrium. In six dogs, a Dacron graft was constructed between the main pulmonary artery and the innominate artery. Constricting and releasing the tape around the graft adjusted the amount of "ductal" shunting. The total pulmonary flow and the shunt flow were measured by electromagnetic-flow transducers around the aortic root and around the graft. Plasma ANF concentration was measured from both cardiac atria. The size of the left atrium was determined from echocardiographic measurements made from a short-axis view. The total pulmonary flow varied between 1.2 and 5.8 1/min. The highest measured ANF was 396 pg/ml, and this was from the left atrium when the pressure was 18 mmHg, the highest left atrial pressure recorded. The highest right atrial pressure (5 mmHg) also correlated with the highest right-atrial level of ANF (366 pg/ml). The right atrial pressure had a significant correlation with plasma ANF concentration (R = 0.43, p less than 0.05). Pulmonary flow and plasma ANF concentration did not correlate; neither did left atrial size and ANF levels in 16 flow states where the size was measured. In the absence of atrial dilatation there was minimal stimulus for ANF secretion. A transient increase of left atrial pressure, without a concomitant significant atrial dilatation, did not serve as a significant stimulus for ANF secretion.

Animals↗

Sources of variability for Doppler color flow mapping of regurgitant jets in an animal model of mitral regurgitation.

To determine whether Doppler color flow mapping could be used to quantify changing levels of regurgitant flow and define the technical variables that influence the size of color flow images of regurgitant jets, nine stable hemodynamic states of mitral insufficiency were studied in four open chest sheep with regurgitant orifices of known size. The magnitude of mitral regurgitation was altered by phenylephrine infusion. Several technical variables, including the type of color flow instrument (Irex Aloka 880 versus Toshiba SSH65A), transducer frequency, pulse repetition frequency and gain level, were studied. Significant increases in the color flow area, but not in color jet width measurements, were seen after phenylephrine infusion for each regurgitant orifice. For matched levels of mitral regurgitation, an increase in gain resulted in a 125% increase in color flow area. An increase in the pulse repetition and transducer frequencies resulted in a 36% reduction and a 28% increase in color flow area, respectively. Jet area for matched regurgitant volumes was larger on the Toshiba compared with the Aloka instrument (5.2 +/- 3.1 versus 3.2 +/- 1.2 cm2, p less than 0.05). Color flow imaging of mitral regurgitant jets is dependent on various technical factors and the magnitude of regurgitation. Once these are standardized for a given patient, the measurement of color flow jet area may provide a means of making serial estimates of the severity of mitral insufficiency.

Animals↗

Closure of the ductus arteriosus and mechanics of breathing in preterm infants after surfactant replacement therapy.

Treatment of premature infants with exogenous surfactant is thought to increase the incidence of the patent ductus arteriosus (PDA) due to improved mechanics of breathing and the resultant reduced pulmonary vascular resistance. As part of a prospective, blinded, controlled study of human amniotic fluid-derived surfactant, we assessed the time of closure of the PDA, defined by Doppler echocardiographic studies, performed at 6-h intervals, and the mechanics of breathing at 6, 18, and 30 h of age in 61 infants (gestational age, 25-29 wk, and birth wt, 450-1580 g). All infants had respiratory distress syndrome as confirmed by immature surfactant phospholipid profiles determined on either amniotic fluid and/or tracheal aspirate analysis, and chest radiograph, and all had a PDA at 6 h of age. Surfactant treatment was associated with more frequent clinically determined need for treatment of the PDA, but did not prolong the patency of the ductus in infants with spontaneous closure or in those requiring treatment with indomethacin. Infants with spontaneous closure of the PDA had significantly higher dynamic lung compliances and lower oxygen requirements and were treated with lower mean airway pressures than those requiring PDA treatment, although their arterial blood gas status was the same. The dynamic lung compliance of infants with right to left ductal shunting was significantly lower than those with left to right shunting at 6 and 18 h but was not different thereafter. This study suggests that the maturity of the ductus arteriosus, reflected by its tendency to close spontaneously, parallels the maturity of the lungs, reflected by their mechanical stability, and that ductal closing is not significantly altered by surfactant therapy.

Clinical Trials as Topic↗

Noninvasive Doppler color flow mapping for detection of anomalous origin of the left coronary artery from the pulmonary artery and for evaluation of surgical repair.

Anomalous origin of the left coronary artery from the pulmonary artery is a rare but important cause of congestive heart failure in infancy and of sudden death at all ages. Diagnosis is often missed when based solely on physical examination and noninvasive methods. A 4 year old patient is presented in whom mitral regurgitation was noted by a referring physician and an anomalous left coronary artery was found by Doppler color flow mapping upon referral and verified at cardiac catheterization. Doppler color flow mapping was also used intraoperatively using a gas-sterilized transducer to further clarify the hemodynamics and assess the surgical result. After creation of an intrapulmonary artery tunnel from the ostium of the left coronary artery to the aorta, anterograde coronary artery flow and absence of a residual left to right pulmonary artery shunt were verified during surgery by Doppler flow mapping. Postoperatively, residual mitral regurgitation and patency of the left coronary artery graft have been followed up serially by Doppler flow mapping. Therefore, Doppler color flow mapping is useful in the diagnosis and intraoperative and postoperative management of this important and potentially life-threatening abnormality.

Blood Vessel Prosthesis↗

Two-dimensional Doppler color flow mapping for detecting atrial and ventricular septal defects. Studies in an animal model and in the clinical setting.

In experimental studies in six dogs as well as in clinical studies in eleven patients with atrial septal defect and 27 patients with ventricular septal defect, the diagnostic usefulness of color Doppler echocardiography in detection of small septal defects and multiple defects was analyzed. The study showed that atrial or ventricular septal defects with a size of 2.5 to 3 mm or more, which eluded detection with two-dimensional echocardiography, were easily identified with the color Doppler method. Additionally, multiple defects were reliably demonstrated. In atrial septal defects, according to the results of this study, the shunt area in the color Doppler image enables a semiquantitative estimation of the shunt volume.

Adolescent↗

[The social and medical situation of people suffering from multiple sclerosis--considerations on the basis of an epidemiologic field study (author's transl)].

Within the framework of an epidemiologic field study conducted in South Niedersachsen a standardised questionnaire was used to obtain data on the social and medical situation of persons with multiple sclerosis. Of the 195 people with multiple sclerosis questioned in that area in 1976 answers were received from 178 (91%). The mean age was 46 years, the average history of disease 15 years. Family status and social position corresponded to social average. A social downfall as a result of the disease was not found to have taken place. Approximately 50% who had been employed prior to the disease (N = 147) had given up their jobs at the time of the survey. The monthly net income was found to be average. Of the studied persons 42% were living in their own houses or flats. A lower percentage, compared to the general public, was living in lodgings (58% instead of 65,7%). The majority (56%) was living in flats suitable for the disabled. 13% of the surveyed persons lived alone, 5% in homes. Social care was found to be very poor in comparison with medical treatment. The introduction of compulsory notification for this disease was advocated by 83% of the people questioned.

Adolescent↗