Study of a noncovalent trp repressor: DNA operator complex by electrospray ionization time-of-flight mass spectrometry.

Electrospray ionization time-of-flight mass spectrometry (ESI-TOF MS) has been used to study noncovalent interactions between the trp apo-repressor (TrpR), its co-repressor tryptophan and its specific operator DNA. In 5 mM ammonium acetate, TrpR was detected as a partially unfolded monomer. In the presence of a 21-base-pair DNA possessing the two symmetrically arranged CTAG consensus sequences required for specific TrpR binding, a homodimer-dsDNA complex with a 1:1 stoichiometry was observed. Co-repressor was not needed for the complex to form under our experimental conditions. Collision induced dissociation (CID-MS) revealed that this complex was very stable in the gas phase since dissociation was achieved only at energies that also broke covalent bonds. We saw no evidence for the presence of the six water molecules that mediate the interaction between the protein and the DNA in the crystal structure. To check the binding specificity of the TrpR for its target DNA, a competitive experiment was undertaken: the protein was mixed with an equimolar amount of three different DNAs in which the two CTAG sequences were separated by 2, 4, and 6 bp, respectively. Only the DNA with the correct consensus spacing of 4 bp was able to form stable interactions with TrpR. This experiment demonstrates the potential of ESI-MS to test the sequence-specificity of protein-DNA complexes. The interactions between the TrpR-DNA complex and 5-methyl-, L- and D-tryptophan were also investigated. Two molecules of 5-methyl- or L-tryptophan were bound with high affinity to the TrpR-DNA complex. On the other hand, D-tryptophan appeared to bind to the complex with poor specificity and poor affinity.

Bacterial Proteins↗

Rapid 'de novo' peptide sequencing by a combination of nanoelectrospray, isotopic labeling and a quadrupole/time-of-flight mass spectrometer.

Protein microanalysis usually involves the sequencing of gel-separated proteins available in very small amounts. While mass spectrometry has become the method of choice for identifying proteins in databases, in almost all laboratories 'de novo' protein sequencing is still performed by Edman degradation. Here we show that a combination of the nanoelectrospray ion source, isotopic end labeling of peptides and a quadrupole/ time-of-flight instrument allows facile read-out of the sequences of tryptic peptides. Isotopic labeling was performed by enzymatic digestion of proteins in 1:1 16O/18O water, eliminating the need for peptide derivatization. A quadrupole/time-of-flight mass spectrometer was constructed from a triple quadrupole and an electrospray time-of-flight instrument. Tandem mass spectra of peptides were obtained with better than 50 ppm mass accuracy and resolution routinely in excess of 5000. Unique and error tolerant identification of yeast proteins as well as the sequencing of a novel protein illustrate the potential of the approach. The high data quality in tandem mass spectra and the additional information provided by the isotopic end labeling of peptides enabled automated interpretation of the spectra via simple software algorithms. The technique demonstrated here removes one of the last obstacles to routine and high throughput protein sequencing by mass spectrometry.

Databases, Factual↗

Use of a non-porous polyurethane membrane as a sample support for matrix-assisted laser desorption/ionization time-of-flight mass spectrometry of peptides and proteins.

Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) of proteins and peptides was performed on samples deposited onto non-porous ether-type polyurethane (PU) membranes. Spectra obtained using PU membranes showed that mass resolution and accuracy were equivalent to values observed using a metal target, and superior to those obtained using poly(vinylidene difluoride) (PVDF) membranes. A small apparent increase in the mass of proteins and also loss of resolution were observed at very high laser irradiance due to charging, but were not observed under normal conditions. Analysis of NaCl-doped standards demonstrated that PU membranes yielded better results than a metallic target for salt-containing solutions. Relatively strong hydrophobic interactions between the proteins and peptides and the PU membrane allowed the incorporation of a washing step. This step allowed for the removal of salts and buffer components and thus provided an increase in resolution and mass accuracy. Digestion of citrate synthase (a protein of molecular weight 47,886) with trypsin was performed directly on the surface of the membrane for variable periods of time, and characteristic peptide fragments were observed by MALDI-TOFMS. Delayed extraction was used to increase the resolution and to permit more accurate mass assignments for those fragments. The use of PU membranes for MALDI-TOFMS analysis of proteins with higher molecular weights is also demonstrated.

Citrate (si)-Synthase↗

Identification of a novel bond between a histidine and the essential tyrosine in catalase HPII of Escherichia coli.

A bond between the N delta of the imidazole ring of His 392 and the C beta of the essential Tyr 415 has been found in the refined crystal structure at 1.9 A resolution of catalase HPII of Escherichia coli. This novel type of covalent linkage is clearly defined in the electron density map of HPII and is confirmed by matrix-assisted laser desorption/ionization mass spectrometry analysis of tryptic digest mixtures. The geometry of the bond is compatible with both the sp3 hybridization of the C beta atom and the planarity of the imidazole ring. Two mutated variants of HPII active site residues, H128N and N201H, do not contain the His 392-Tyr 415 bond, and their crystal structures show that the imidazole ring of His 392 was rotated, in both cases, by 80 degrees relative to its position in HPII. These mutant forms of HPII are catalytically inactive and do not convert heme b to heme d, suggesting a relationship between the self-catalyzed heme conversion reaction and the formation of the His-Tyr linkage. A model coupling the two processes and involving the reaction of one molecule of H2O2 on the proximal side of the heme with compound 1 is proposed.

Amino Acid Sequence↗

Preparation and properties of pure, full-length IclR protein of Escherichia coli. Use of time-of-flight mass spectrometry to investigate the problems encountered.

IclR protein, the repressor of the aceBAK operon of Escherichia coli, has been examined by time-of-flight mass spectrometry, with ionization by matrix assisted laser desorption or by electrospray. The purified protein was found to have a smaller mass than that predicted from the base sequence of the cloned iclR gene. Additional measurements were made on mixtures of peptides derived from IclR by treatment with trypsin and cyanogen bromide. They showed that the amino acid sequence is that predicted from the gene sequence, except that the protein has suffered truncation by removal of the N-terminal eight or, in some cases, nine amino acid residues. The peptide bond whose hydrolysis would remove eight residues is a typical target for the E. coli protease OmpT. We find that, by taking precautions to minimize Omp T proteolysis, or by eliminating it through mutation of the host strain, we can isolate full-length IclR protein (lacking only the N-terminal methionine residue). Full-length IclR is a much better DNA-binding protein than the truncated versions: it binds the aceBAK operator sequence 44-fold more tightly, presumably because of additional contacts that the N-terminal residues make with the DNA. Our experience thus demonstrates the advantages of using mass spectrometry to characterize newly purified proteins produced from cloned genes, especially where proteolysis or other covalent modification is a concern. This technique gives mass spectra from complex peptide mixtures that can be analyzed completely, without any fractionation of the mixtures, by reference to the amino acid sequence inferred from the base sequence of the cloned gene.

Amino Acid Sequence↗

The cysteines of catalase HPII of Escherichia coli, including Cys438 which is blocked, do not have a catalytic role.

Site-directed mutagenesis of the katE gene of Escherichia coli was used to change, individually and in combination, Cys438 and Cys669 to serine in catalase HPII. The Cys438-->Ser mutation caused a 30% reduction in the specific activity of the enzyme, whereas the Cys669-->Ser mutation did not affect enzyme activity. The titration of free sulfhydryl groups in HPII revealed that Cys669 was reactive whereas Cys438 was unreactive. Properties of the modification on Cys438 included alkali lability, insensitivity to methylamine, hydroxylamine or reducing agents, and a mass determined by mass spectrometry to be approximately 43 +/- 2 Da. A hemithioacetal structure is consistent with these properties. Although free sulfhydryl groups do not play a significant role in the stability or catalytic mechanism of HPII, the sulfhydryl agent 2-mercaptoethanol caused a 50% inactivation of HPII along with an irreversible change in the absorption spectrum of the protein. Other sulfhydryl agents, including dithiothreitol, cysteine and glutathione, and the organic peroxide, t-butylhydroperoxide, which cannot directly access the active site, do not affect HPII activity, but they do cause a small reversible change in the absorption spectrum, possibly by a mechanism involving superoxide.

Base Sequence↗

Reflecting time-of-flight mass spectrometer with an electrospray ion source and orthogonal extraction.

An electrospray source has been coupled to a reflecting time-of-flight mass spectrometer. The ions enter as a continuous beam in a direction perpendicular to the spectrometer axis and are formed into short bursts of ions with velocities parallel to the axis by electrical pulses applied to injection electrodes. The instrument may be operated either in the linear mode, with ions detected behind the electrostatic mirror, or in the reflecting mode, with ions detected after reflection. In the latter case the time resolution is < or = 8 ns for m/z approximately 600, enabling observation of individual isotopic peaks for masses up to about 4000 u. The sensitivity is adequate to enable measurement of mass spectra for 10 fmol of cytochrome c (approximately 12,000 u). The spectrometer does not limit the range of m/z values, and ions have been observed up to m/z approximately 6000. With proper adjustment of pH and other conditions in the source, the ionization is very soft, enabling injection of weakly bound complexes; these have been accelerated and measured in the spectrometer without observable fragmentation.

Cytochrome c Group↗

Investigation of protein-protein noncovalent interactions in soybean agglutinin by electrospray ionization time-of-flight mass spectrometry.

Noncovalent interactions in soybean agglutinin (SBA) were studied on an electrospray ionization (ESI) time-of-flight mass spectrometer constructed recently at the University of Manitoba. The high m/z range and high sensitivity of the instrument together with mild ESI interface conditions turned out to be ideal for detecting this noncovalently bonded tetrameric protein (MW approximately 116,000 Da) in low charge states (z = 23 to 27). By altering the acetonitrile content of the SBA solutions it was shown that the observed SBA tetramers are due to structurally specific noncovalent associations in solution. Octamers and dodecamers (MW approximately 350,000 Da) were also detected. Information on the quaternary structure of the tetramers was obtained by analyzing the fragment-ion spectrum resulting from the collision-induced dissociation of the tetramer ions.

Lectins↗

Secondary-ion and electron production from surfaces bombarded by large polyatomic ions.

Heavy molecular ions with energies in the range 10-20 keV and masses from 276 u to 132,000 u, produced by matrix-assisted laser desorption, were used as primary projectiles to produce secondary-ion spectra from a variety of surfaces in a tandem time-of-flight mass spectrometer. In the negative mode the ratio of electron emission to secondary-ion emission was found to decrease rapidly with increasing projectile mass. Ion emission was found to dominate for primary ions larger than approximately 10,000 u. Positive or negative molecular ions and cations were observed from several organic targets of masses up to 1140 u (gramicidin S) for incident projectiles up to mass 132,000 u, i.e., for projectile speeds down to approximately 7000 m/s. Other ions characteristic of the target were also observed for these projectiles. Thus, large polyatomic ions can cause secondary-ion desorption even at very low velocity. The background ions of both polarities are similar to those found in keV particle bombardment by monatomic projectiles. The same ions are observed for all the projectiles; most can be identified with hydrocarbon background. The relative intensities of the background positive ions are largely independent of projectile, and for both polarities the ratio of the ions characterizing the target to those forming the background is approximately constant for all the projectiles. These results strongly suggest that the background ions come from the usual layer of organic impurities attached to the target surface. No direct evidence for surface-induced dissociation was observed in this mass and energy range.

Mass Spectrometry↗

Kinetic energy measurements of molecular ions ejected into an electric field by matrix-assisted laser desorption.

Measurements of kinetic energy distributions of molecular ions ejected into an extraction field by matrix-assisted laser desorption are reported. The measurements were made in a time-of-flight mass spectrometer with an electrostatic mirror by measuring the reflected signal as a function of the difference between the accelerating voltage and the voltage applied to the mirror. The molecular ions were found to have less kinetic energy than the extraction field alone would normally provide, i.e., we observed an energy deficit. Under conditions typical for a matrix-assisted laser desorption experiment, the deficit is about 24 eV for molecular ions of insulin. The size of the deficit increases with the intensity of the molecular ion signal, and the molecular weight of the protein; it is also larger for negative molecular ions than for positive molecular ions.

Animals↗

Properties of matrix-assisted laser desorption. Measurements with a time-to-digital converter.

Some properties of matrix-assisted laser desorption have been studied using single-ion-counting methods and a time-to-digital converter. The methods allow examination of the process for irradiances near the reported threshold for observation with a transient recorder. All measurements were made using bovine insulin as a test compound. We present direct evidence that an irradiance threshold near 10(6) W cm-2 exists for ion production, and that the process is a collective effect, either involving a large number of molecular ions (approximately 10(4) in a successful event or none at all. Above the threshold, the yield is found to scale with a high power (4th to 6th) of the irradiance. Measurements of initial velocity distributions indicate an axial velocity spread corresponding to approximately 50 eV and a radial velocity spread corresponding to approximately 2.4 eV. Thus the ejection or extraction mechanism appears to be strongly asymmetric.

Animals↗

Measurement of unimolecular decay in peptides of masses greater than 1200 units by a reflecting time-of-flight mass spectrometer.

Daughter ions from decomposition of [M + H]+ parent ions have been observed in a time-of-flight mass spectrometer fitted with an ion mirror. Unit mass resolution is obtained for parent ions of masses up to several thousand u when the mirror voltage is set at a value determined by the usual velocity-focusing criterion for parent ions. Under this condition the daughter-ion resolution in the low-mass range suffers. Considerable improvement is obtained when the daughter-ion spectrum is examined in several segments, with the mirror voltage optimized for each segment. The daughter-ion spectrum from decay of metastable [M + H]+ parent ions in Substance P is measured using this technique. Reasons are suggested for differences between the spectrum obtained and a spectrum for the same compound recently obtained using a tandem double-focusing instrument.

Endorphins↗

Redox reactions occurring during secondary ion mass spectrometry of some heteroanthracycline antitumor antibiotic precursors.

Positive and negative secondary ion mass spectra of the title compounds were produced by bombardment of solid deposits by 13 and 23 KeV cesium ions, respectively, and analyzed with a time-of-flight mass spectrometer. In addition to familiar protonation and alkali (mainly sodium) ion addition processes observed in the positive ion spectra and proton abstractions in the negative ion spectra (which enable determination of molecular weight) there is evidence from both spectral modes for oxidation-reduction processes in which species such as [M - H]+, [M - H + Na]+. and [M + 1]- are formed. It is argued that these may be formed rapidly from pre-associated molecules during bombardment/ionization rather than as a result of radiation damage. Sodium ion addition is apparently facilitated by the presence of electron pair donor groups, especially if chelation is possible.

Antibiotics, Antineoplastic↗

Automated dry fraction collection for microbore high-performance liquid chromatography-mass spectrometry.

A method is presented for the collection of dry fractions from a microbore high-performance liquid chromatographic column. These fractions are electrosprayed onto a foil strip that is being moved past the spray in steps. These solid deposits are in a form which is compatible with solid-phase secondary-ion mass spectrometry, in particular the time-of-flight instrument that has been developed in our laboratory. Because the type of ionization used in static secondary-ion spectrometry is essentially non-destructive, the non-volatile eluent is available for any other analytical method after mass analysis. The chromatogram of a mixture of peptides was re-constructed from the mass spectra of fractions collected in this way. This chromatogram is shown and its features are examined.

Buffers↗