PubMed Health⌕ Search

Biomedical subjects

W F Beckert

Publications and source records attributed to W F Beckert.

6 recordsLinked to original sources

Cleanup of environmental sample extracts using Florisil solid-phase extraction cartridges.

Disposable cartridges containing 1 g of Florisil are investigated for cleanup of extracts obtained from various environmental matrices. Elution patterns and recoveries are determined for 22 chlorinated hydrocarbons and 16 phthalate esters in the presence of interferents such as corn oil, diesel hydrocarbons, organochlorine pesticides, and chlorinated phenols. Hexane, hexane/diethyl ether (1:1), hexane/acetone (9:1), and various combinations of hexane/methylene chloride are used as eluants.

Chromatography, Gas↗

Evaluation of a high-resolution gas chromatography/high-resolution mass spectrometry method for the determination of 2,3,7,8-tetrachlorodibenzo-p-dioxin in soil and water.

An analytical protocol for the determination of 2,3,7,8-tetrachlorodibenzo-p-dioxin (2,3,7,8-TCDD) and total TCDDs in soil, sediment, and aqueous samples using high-resolution gas chromatography/high-resolution mass spectrometry (HRGC/HRMS) was evaluated through replicate analyses of fortified and unspiked soil and aqueous samples. The results of these analyses demonstrated that the method is useful for the determination of 2,3,7,8-TCDD and total TCDDs at concentrations ranging from 10 to 200 pg/g (ppt) in soil samples and from 100 to 2000 pg/l (ppq) in aqueous samples. Absolute recoveries of the method internal standard, (13C12-2,3,7,8-TCDD, ranged from 24 to 88%. Lower levels of detection can be achieved through a slight modification of the method with respect to initial sample size and/or final extract volume. Instrumental parameters that affect data quality, specifically HRGC column performance, mass resolution and mass measurement accuracy are presented.

Dioxins↗

Single-laboratory evaluation of EPA method 8080 for determination of chlorinated pesticides and polychlorinated biphenyls in hazardous wastes.

Method 8080, as published in the Second Edition of "Test Methods for Evaluating Solid Waste," EPA Manual SW-846, has been evaluated in a single-laboratory study. The Florisil procedure recommended in Method 8080 for sample cleanup does not separate organochlorine pesticides (OCPs) from the polychlorinated biphenyls (PCBs). Consequently, gas chromatographic analysis of OCPs on the packed column recommended in the method may result in false identifications or in no identifications at all when PCBs are present. Therefore, silica gel was substituted for Florisil, a capillary column was substituted for the packed column, and a sulfur cleanup procedure was incorporated in the method. The revised method was evaluated with samples spiked at 3 concentrations. Precision and accuracy indicate that the revised method can be reliably applied to the determination of OCPs and PCBs in liquid and solid matrixes. Detection limits for liquid matrixes range from 0.02 to 0.09 micrograms/L for OCPs and from 0.5 to 0.9 micrograms/L for PCBs. Detection limits for solid matrixes range from 1 to 6 micrograms/kg for OCPs and from 60 to 70 micrograms/kg for PCBs.

Chromatography, Gas↗

Interlaboratory evaluation of an off-line supercritical fluid extraction/infrared spectrometric method for determination of petroleum hydrocarbons in solid matrixes.

A collaborative study was conducted, with 14 laboratories participating, to determine the method accuracy and precision of the proposed U.S. Environmental Protection Agency Methods 3560 and 8440. These methods involve the extraction of petroleum hydrocarbons from solid matrixes with supercritical carbon dioxide at 340 atm and 80 degrees C for 30 min (dynamic), collection of the extracted materials in tetrachloroethene (Method 3560), and analysis of the extracts by infrared (IR) spectrometry (Method 8440). The study design was based on the AOAC blind replicate design with balanced replicates. The study samples consisted of 4 solid matrixes that had petroleum hydrocarbon contents ranging from 614 to 32,600 mg/kg. Each of the 4 matrixes was extracted in triplicate, and the extracts were analyzed with 2 different IR spectrometers. In addition, each of the participating laboratories extracted a sample of unspiked clay soil, the same clay soil spiked with corn oil and reference oil at 1000 mg/kg each, and the same clay soil wetted to 30% water content and spiked with motor oil at 10,000 mg/kg (the latter 3 samples were extracted only once). Results indicated that the overall method accuracy for concentrations ranging from 614 to 32,600 mg/kg was 82.9%; the mean recoveries of petroleum hydrocarbons for each of the 4 solid matrixes ranged from 77.9 to 107% for analyses performed with the Perkin-Elmer Fourier transform IR spectrometer and from 75.9 to 101% for analyses performed with the Buck-Scientific IR spectrometer; the differences between the 2 instruments on a sample-by-sample basis were less than 17% for the total petroleum hydrocarbon determinations. The interlaboratory method precisions (RSDR) appeared to be matrix-dependent and ranged from 17.3 to 45.4% for analyses performed with the Perkin-Elmer Fourier transform IR spectrometer and from 16.7 to 47.9% for the Buck-Scientific IR spectrometer. The intralaboratory method precisions (RSDr) appeared to be less matrix-dependent and ranged from 11.5 to 17.0% for analyses performed with the Perkin-Elmer FTIR spectrometer and from 11.1 to 18.2% for the Buck-Scientific IR spectrometer. Method accuracy and precision data are also presented for the 5 laboratories that used Isco supercritical fluid extraction systems and for the 7 laboratories that used vessels with volumes of 3.5 mL or less with different supercritical fluid extraction systems.

Aluminum Silicates↗