PubMed Health⌕ Search

Biomedical subjects

W F Block

Publications and source records attributed to W F Block.

7 recordsLinked to original sources

Effects of forced diving on the spleen and hepatic sinus in northern elephant seal pups.

In phocid seals, an increase in hematocrit (Hct) accompanies diving and periods of apnea. The variability of phocid Hct suggests that the total red cell mass is not always in circulation, leading researchers to speculate on the means of blood volume partitioning. The histology and disproportionate size of the phocid spleen implicates it as the likely site for RBC storage. We used magnetic resonance imaging on Northern elephant seals to demonstrate a rapid contraction of the spleen and a simultaneous filling of the hepatic sinus during forced dives (P < 0.0001, R(2) = 0.97). The resulting images are clear evidence demonstrating a functional relationship between the spleen and hepatic sinus. The transfer of blood from the spleen to the sinus provides an explanation for the disparity between the timing of diving-induced splenic contraction ( approximately 1-3 min) and the occurrence of peak Hct (15-25 min). Facial immersion was accompanied by an immediate and profound splenic contraction, with no further significant decrease in splenic volume after min 2 (Tukey-Kramer HSD, P = 0.05). At the conclusion of the dive, the spleen had contracted to 16% of its predive volume (mean resting splenic volume = 3,141 ml +/- 68.01 ml; 3.54% of body mass). In the postdive period, the spleen required 18-22 min to achieve resting volume, indicating that this species may not have sufficient time to refill the spleen when routinely diving at sea, which is virtually continuous with interdive surface intervals between 1 and 3 min.

Animals↗

Undersampled projection reconstruction applied to MR angiography.

Undersampled projection reconstruction (PR) is investigated as an alternative method for MRA (MR angiography). In conventional 3D Fourier transform (FT) MRA, resolution in the phase-encoding direction is proportional to acquisition time. Since the PR resolution in all directions is determined by the readout resolution, independent of the number of projections (Np), high resolution can be generated rapidly. However, artifacts increase for reduced Np. In X-ray CT, undersampling artifacts from bright objects like bone can dominate other tissue. In MRA, where bright, contrast-filled vessels dominate, artifacts are often acceptable and the greater resolution per unit time provided by undersampled PR can be realized. The resolution increase is limited by SNR reduction associated with reduced voxel size. The hybrid 3D sequence acquires fractional echo projections in the k(x)-k(y) plane and phase encodings in k(z). PR resolution and artifact characteristics are demonstrated in a phantom and in contrast-enhanced volunteer studies.

Artifacts↗

Undersampled projection-reconstruction imaging for time-resolved contrast-enhanced imaging.

In time-resolved contrast-enhanced 3D MR angiography, spatial resolution is traded for high temporal resolution. A hybrid method is presented that attempts to reduce this tradeoff in two of the spatial dimensions. It combines an undersampled projection acquisition in two dimensions with variable rate k-space sampling in the third. Spatial resolution in the projection plane is determined by readout resolution and is limited primarily by signal-to-noise ratio. Oversampling the center of k-space combined with temporal k-space interpolation provides time frames with minimal venous contamination. Results demonstrating improved resolution in phantoms and volunteers are presented using angular undersampling factors up to eight with acceptable projection reconstruction artifacts.

Abdomen↗

Phase-contrast with interleaved undersampled projections.

MR phase-contrast techniques provide velocity-sensitive angiograms and quantitative flow measurements but require long scan times. Recently it has been shown that undersampled projection reconstruction can acquire higher resolution per unit time than Fourier techniques with acceptable artifacts when used in contrast-enhanced MR angiography. Undersampled projection reconstruction has similar potential for phase-contrast acquisitions. Flow sensitization gradients are used with projection trajectories to acquire velocity-dependent phase information. An acquisition scheme that acquires three flow encoding directions on three sets of angular-interleaved projections is introduced. Depending on the resolution, acquisition times for 3D datasets can decrease by factors of two to four.

Artifacts↗

Single breath-hold 3D contrast-enhanced method for assessment of cardiac function.

Cardiac MRI function measurements are typically performed using 2D sequences and require multiple breath-holds to image the entire heart. A single 3D acquisition using a T(1)-shortening agent has many potential advantages over techniques that acquire multiple 2D images, including more consistent contrast and precise slice coverage. However, 3D techniques currently require much longer than a single breath-hold to complete. It has been shown that for MR angiography undersampled projection reconstruction can acquire much higher resolution per unit time than Fourier imaging with acceptable artifacts. By employing a gated, undersampled projection technique, high-resolution 3D multiphase volumes of the heart can be acquired in a single breath-hold. Short repetition times result in good myocardial suppression and a temporal aperture of 60 ms.

Contrast Media↗

Magnetic resonance imaging of frozen tissues: temperature-dependent MR signal characteristics and relevance for MR monitoring of cryosurgery.

Previously, the magnetic resonance (MR) imaging appearance of frozen tissues created during cryosurgery has been described as a signal void. In this work, very short echo times (1.2 msec) allowed MR signals from frozen tissues to be measured at temperatures down to -35 degrees C. Ex vivo bovine liver, muscle, adipose tissue, and water were imaged at steady-state temperatures from -78 degrees to +6 degrees C. Signal intensity, T2*, and T1 were measured using gradient-echo imaging. Signal intensity and T2* decrease monotonically with temperature. In the future, these MR parameters may be useful for mapping temperatures during cryosurgery.

Adipose Tissue↗

Breast lesion localization: a freehand, interactive MR imaging-guided technique.

PURPOSE: To evaluate interactive magnetic resonance (MR) imaging-guided preoperative needle localization and hookwire placement in the noncompressed breast in patients in the prone position. MATERIALS AND METHODS: Nineteen MR imaging-guided breast lesion localization procedures were performed in 17 patients aged 38-70 years (mean age, 48 years) by using an open-platform breast coil in either a 1.5-T, closed-bore imager (n = 14) or a 0.5-T, open-bore imager (n = 5). Rapid imaging (fast spin-echo, water-selective fast spin-echo, or water-specific three-point Dixon gradient-echo) was alternated with freehand manipulation of an MR-compatible needle to achieve accurate needle placement. RESULTS: Up to three manipulations of the needle were required during an average of 9 minutes to reach the target lesion. MR imaging findings confirmed the final needle position within 9 mm of the target in all cases. The accuracy of 10 localizations was independently corroborated either at mammography or at ultrasonography. Nine lesions were visible on MR images only. CONCLUSION: Interactive MR imaging-guided, freehand needle localization is simple, accurate, and requires no special stereotactic equipment. Lesions throughout the breast, including those in the anterior part of the breast and those near the chest wall, which can be inaccessible with standard grid or compression-plate techniques, can be localized. A variety of needle trajectories in addition to the horizontal path are possible, including circumareolar approaches and tangential needle paths designed to avoid puncture of implants.

Adult↗