PubMed Health⌕ Search

Biomedical subjects

W Friedman

Publications and source records attributed to W Friedman.

At least 19 recordsLinked to original sources

Topography of whisking II: interaction of whisker and pad.

The peripheral effector system mediating rodent whisking produces protraction/retraction movements of the whiskers and translation movements of the collagenous mystacial pad. To examine the interaction of these movements during whisking in air we used high-resolution, optoelectronic methods for two-dimensional monitoring of whisker and pad movements in head-fixed rats. Under these testing conditions (1) whisker movements on the same side of the face are synchronous and of similar amplitude; (2) pad movements exhibit the characteristic 'exploratory' rhythm (6-12 Hz) of whisking but their movements often have a low frequency (1-2 Hz) component; (3) Pad movements occur in both antero-posterior and dorso-ventral planes but there are considerable variations in the amplitude and topography of movement parameters in the two planes. We conclude that (a) both whisker and pad receive input from a common central rhythm generator; (b) differences in whisker and pad amplitude and topography probably reflect differences in the biomechanical properties of the structures receiving that input; (c) pad movements make a significant contribution to the kinematics of whisking behavior and (d) the two-dimensional nature of pad translation movements significantly increases the rat's flexible control of its mobile sensor.

Animals↗

Cognitive and vestibulo-proprioceptive components of spatial ability in Parkinson's disease.

Visual-spatial deficits are often associated with Parkinson's Disease (PD). Recent theories suggest that frontal-basal ganglionic dysfunction affects cognition in PD. Although this hypothesis does not entirely explain spatial deficits in PD, the inappropriate utilization of cues associated with executive dysfunction may induce spatial deficits. Alternatively, the vestibular system is also involved in spatial cognition, and vestibular dysfunction may affect visual-spatial ability in PD. To test these hypotheses, we administered the Water Jar Test, while perturbing vestibulo-proprioceptive input. Non-demented PD patients were significantly less accurate than controls in judging horizontal, and appeared to inappropriately utilize cues. No group effect was found for head tilt. These findings suggest the visual-spatial difficulties seen in PD are related to executive dysfunction that is associated with a disruption of the frontal-basal ganglionic and frontal-parietal systems.

Basal Ganglia↗

Changes in vocal intensity in Parkinson's disease following pallidotomy surgery.

The present study was designed to examine changes in vocal intensity following unilateral posteroventral pallidotomy (PVP) in a large sample of speakers with Parkinson's disease (PD) that exhibited a range of hypokinetic dysarthria. Twenty-five persons with PD were recorded using a variety of speech tasks, once prior to and once following PVP. The pre-PVP vocal SPL was subtracted from the post-PVP vocal SPL to derive a relative change in vocal SPL. Mildly dysarthric participants had significantly greater relative increases in vocal SPL following PVP than either moderately or severely dysarthric participants who had reduced vocal SPL following PVP. If future results follow those observed in the present data, mildly dysarthric Parkinson's patients may benefit most from unilateral PVP perhaps due to less overall destruction of the basal ganglia sensorimotor control circuits involved in oral facial functions, thus increasing the chances to observe improvements postsurgery.

Aged↗

Voice and speech characteristics of persons with Parkinson's disease pre- and post-pallidotomy surgery: preliminary findings.

Pallidotomy surgery, lesioning the globus pallidus internal, has been performed to alleviate Parkinsonian symptoms and drug-induced dyskinesias. Improvements in limb motor function have been reported in recent years following pallidotomy surgery. The purpose of this preliminary study was to determine the effect of pallidotomy surgery on select voice and speech characteristics of 6 patients with Parkinson's disease. Acoustic measures were analyzed pre-pallidotomy surgery and again at 3 months following surgery. Preliminary findings indicated that all participants demonstrated positive changes in at least one acoustic measure; 2 of the participants consistently demonstrated positive changes in phonatory and articulatory measures, whereas 3 participants did not consistently demonstrate positive changes postsurgery. The results are discussed relative to the differential effects observed across participants.

Aged↗

Rapid accurate entry of microbiology results.

OBJECTIVE: To develop techniques to improve efficiency and accuracy of data entry in microbiology, using a commercially available laboratory information system that is keystroke-intensive. DESIGN: A combination of technologies, including bar-coded phrase sheets, keyboard macros, and bar-coded specimen labels, are used to automate the entry of commonly used keystroke sequences and combinations of culture findings. SETTING: An acute care hospital laboratory. PARTICIPANTS: Laboratory technologists. OUTCOME MEASURES: Feasibility, report error rates, and technologist time. RESULTS: Qualitative: implementation of all three technologies proved feasible and practical. Quantitative: a 25-fold decrease in misreported cultures, as well as a 50% saving in reading time for new urine cultures. CONCLUSIONS: This set of technologies for keystroke reduction would be of general applicability to laboratories with a variety of different laboratory information systems.

Bacteria↗

Impulses and resting membrane properties of small cultured rat hippocampal neurons.

1. The impulses and resting membrane parameters of small (soma diameter less than 10 microM) cultured hippocampal neurons from rat embryos were studied with the tight-seal whole-cell recording technique. 2. Mean resting potential was -47 mV, mean input resistance 3.3 G omega, mean capacitance 11 pF, and mean time constant 33 ms. 3. Rectangular suprathreshold current steps elicited regenerative potential responses. The amplitude and time course of the responses were clearly stimulus dependent: stronger current steps caused impulses of larger amplitude. 4. The current threshold was very low: rheobase current was less than 15 pA. 5. The potential response depended on the preceding holding potential, responses from more negative potentials showing sharper peaks than those from more positive potentials. 6. Spontaneous impulses with pre-potentials similar to synaptically induced events were recorded from several cells. The amplitude of the spontaneous impulses varied similarly to that of the stimulus-induced responses.

Action Potentials↗

[Value of radioimmunoscintigraphy compared to computed tomography in the diagnosis and follow-up of primary ovarian carcinoma].

In this prospective study the diagnostic merit of radioimmunoscintigraphy (RIS) was compared with computed tomography (CT) and operation in the primary diagnostic procedure and follow-up of women with suspected ovarian cancer. In primary diagnosis, sensitivity, specificity, and diagnostic accuracy was 100%, 60% and 90% for RIS. In follow-up, sensitivity for local recurrence was slightly higher in CT than in RIS. It was possible to detect peritoneal carcinosis in the pelvis and lower abdominal region better with RIS, but in the upper abdominal region, peritoneal carcinosis was detected better with CT. If no differentiation between benign or malignant lesion, is possible with CT, differentiation will in many cases be possible with RIS.

Adenocarcinoma, Mucinous↗

Electrophysiological evaluation of the patient with acute spinal cord injury.

This article reviews basic principles, equipment and techniques, and clinical applications of electrophysiologic monitoring in patients with spinal cord injuries. Four groups of electrophysiologic measurements are considered: Somatosensory evoked potentials (SEPs); motor evoked potentials (MEPs); electromyography (EMG) and nerve conduction studies; and late responses, including H reflex, M response, and F wave. Reports of SEP recordings in spinal cord injury, as drawn from the literature, are tabulated in detail.

Electromyography↗

Release of luteinizing hormone in prepubertal and middle-aged ovariectomized rats.

Concentrations of circulating LH were determined in conscious, free-moving ovariectomized rats. All of the animals had been ovariectomized at 24 days of age. Between 30 and 90 days there was an increase in mean blood LH concentrations; a more vigorous pulsatile release of LH characterized by an increase in amplitude and frequency of LH release; and an elevated responsiveness to LHRH administration. Rats which had been ovariectomized for 1 year still had elevated blood LH levels but had episodic pulses of reduced amplitude and a decrease in responsiveness to LHRH. These data suggest that important alterations occur with age in the neuroendocrine mechanisms responsible for the release of LH.

Aging↗

One whisker whisking: unit recording during conditioned whisking in rats.

Understanding of the functional neurobiology of the rodent whisker system would be advanced by neurobehavioral studies in awake, behaving animals that combine unit recording from structures at various levels of the system with quantitative characterization of the kinematics and temporal organization of whisking. Such studies require the solution of a number of methodological problems. These include: chronic recording procedures ensuring unit isolation, stability and maximum yield, monitoring and display of unit activity and whisker movements within the same (ms) timeframe and behavioral paradigms which bring whisking movement parameters under the control of the experimenter rather than the rat. Here we describe a head-fixed rodent preparation which makes possible chronic recording of unit activity in the awake, whisking rat, combined with real-time, high resolution monitoring of whisker and pad movements in two dimensions and under behavioral control. While the head-fixed "whisking" preparation has some inherent limitations, it may be used to address a number of important neurobehavioral problems. We suggest that it should contribute significantly to understanding the functional neurobiology of the whisker system.

Animals↗

Release of lead-containing particles from a wall enclosure.

The 1995 Department of Housing and Urban Development (HUD) Guidelines for the Evaluation and Control of Lead-Based Paint Hazards in Housing discusses using interior and exterior wall enclosures for lead hazard control. Leaded dust may be aerosolized inside enclosures and released through gaps and cracks into a room. The effects of airflow and mechanical disturbances on dust release were studied using a laboratory wall enclosure model with dust collected from homes with lead-based paint hazards. Airflows relevant to residences were blown down the enclosure and out a 4-, 6-, or 8-mm horizontal gap at its bottom, simulating potential enclosure failure. Then, low-frequency mechanical vibrations also were applied to the enclosure. No significant dust release was found when blowing air down the enclosure even at 37 cm/sec (representing extremely high flow); release occurred only with this high flow and 3 Hz mechanical disturbances. Dust was released primarily from the floor area immediately adjacent to the enclosure gap; the release rate fluctuated over time. Most dust initially settled near the enclosure. Dust release for 1 hour at extreme conditions (high airflow with vibration) yields lead loading above the 1995 HUD clearance level of 100 microg/ft2 only within 3-4 cm of the wall; for the HUD standard (1 ft2) sampling area, the lead loading does not exceed 30 microg/ ft2. Redistributing dust over the room's 16 m2 floor space yields average extreme-condition loading rate of 2 microg/ft2/hour. At less-than-extreme conditions, dust would have to be released for years without cleaning to yield a hazard.

Dust↗

Particle settling after lead-based paint abatement work and clearance waiting period.

This study investigated the evolution of airborne particle concentration and size distribution following abatement work in a controlled environment utilizing direct real-time particle monitoring and used it to project potential lead loadings as those particles settle. An 860 ft3 environmental test chamber with sophisticated ventilation and air purifying systems was built. Wooden doors with lead-based paint were dry sanded or scraped to generate the highest feasible airborne lead concentrations. Size-fractional airborne particle concentrations decreased exponentially with time in all tests, even with no air exchange, consistent with the stirred model of constantly mixed air, which predicts longer settling than for tranquil settling. Very low levels of air mixing generated by temperature gradients and initial room air turbulence affected particle settling. About 90% of airborne lead mass settled within 1 hour after active abatement, before final cleaning began. During the second waiting period of 1 hour, which followed cleaning of the floor, additional dust settled so that the additional potential lead loading from remaining airborne lead was less than 20 microg/ft2. For this worst case scenario, the underestimate of the lead loading done by the clearance sampling did not exceed about 30%. For more realistic conditions, the underestimates are projected to be much lower than the new 40 microg/ft2 Housing and Urban Development (HUD) clearance standards for floor dust lead. These results were obtained for the first waiting period (between the end of active abatement and the beginning of cleaning) of 1 hour, as recommended by HUD guidelines. Thus, this study demonstrates no need to increase either the first or second waiting period.

Air Pollutants, Occupational↗

Test methods for evaluating the filtration and particulate emission characteristics of vacuum cleaners.

The overall filtration efficiency of a vacuum cleaner traditionally has been tested by placing the vacuum cleaner in a test chamber and measuring aerosol concentrations at the chamber inlet and outlet. The chamber test method was refined and validated in this study. However, this chamber test method shows an overall filtration efficiency of close to 100% for most of the industrial vacuum cleaners and for most of the newly developed household vacuum cleaners of midprice range or higher because all these vacuum cleaners have a high-efficiency particulate air (HEPA) or other highly efficient filter installed at the exhaust. A new test method was therefore developed through which the vacuum cleaner was probed in various internal locations so that the collection efficiency of the individual components could be determined. For example, the aerosol concentration upstream of the final HEPA filter can thus be measured, which permits one to estimate the life expectancy of this expensive component. The probed testing method is particularly suitable for field evaluations of vacuum cleaners because it uses compact, battery-operated optical particle size spectrometers with internal data storage. Both chamber and probed tests gave the same results for the aerosol filtration efficiency. The probed testing method, however, also gives information on the performance of the individual components in a vacuum cleaner. It also can be used to determine the dust pickup efficiency and the degree of reaerosolization of particles collected in the vacuum cleaner.

Air Pollution, Indoor↗

Particle emission characteristics of filter-equipped vacuum cleaners.

Industrial vacuum cleaners with final high-efficiency particulate air (HEPA) filters traditionally have been used for cleanup operations in which all of the nozzle-entrained dust must be collected with high efficiency, for example, after lead-based paint abatement in homes. In this study household vacuum cleaners ranging from $70 to $650 and an industrial vacuum cleaner costing more than $1400 were evaluated relative to their collection efficiency immediately after installing new primary dust collectors in them. Using newly developed testing technology, some of the low-cost household vacuum cleaners equipped with a final HEPA filter were found to have initial overall filtration efficiencies comparable to those of industrial vacuum cleaners equipped with a final HEPA filter. The household vacuum cleaners equipped with a final HEPA filter efficiently collect about 100% of the dry dust entrained by the nozzle. For extensive cleaning efforts and for vacuum cleaning of wet surfaces, however, industrial vacuum cleaners may have an advantage, including ruggedness and greater loading capacity. The methods and findings of this study are applicable to field evaluations of vacuum cleaners.

Aerosols↗