Publications and source records attributed to W G Alberts.

6 recordsLinked to original sources

Why it is advisable to keep wR = 1 and Q = 1 for photons and electrons.

It has been well known for a long time that the biological effectiveness of photons and electrons depends on the mean linear energy transfer (LET) of the radiation considered, e.g. (60)Co gamma rays are less effective than soft or hard X rays. Nevertheless, the protection and operational dose quantities applied in radiological protection include weighting factors, w(R) or Q, respectively, which were set to 1 for all low-LET radiations. Lack of precise information, simplicity and general practical considerations are the main arguments for this convention. However, a more detailed discussion on the practical aspects supporting this procedure is missing. The paper discusses in more detail some of these aspects regarding internal and external exposure situations, which may support the idea of continuing to use w(R) = 1 for photons and electrons and, correspondingly, using Q(L) = 1 for L < 10 keV microm(-1).

Electrons↗

A directional dose equivalent monitor for neutrons.

A directional dose equivalent monitor is introduced which consists of a 30 cm diameter spherical phantom hosting a superheated drop detector embedded at a depth of 10 mm. The device relies on the similarity between the fluence response of neutron superheated drop detectors based on halocarbon-12 and the quality-factor-weighted kerma factor. This implies that these detectors can be used for in-phantom dosimetry and provide a direct reading of dose equivalent at depth. The directional dose equivalent monitor was characterised experimentally with fast neutron calibrations and numerically with Monte Carlo simulations. The fluence response was determined at angles of 0, 45, 90, 135 and 180 degrees for thermal to 20 MeV neutrons. The response of the device is closely proportional to the fluence-to-directional dose equivalent conversion coefficient, h'phi (10; alpha, E). Therefore, our monitor is suitable for a direct measurement of neutron directional dose equivalent, H'(10), regardless of angle and energy distribution of the neutron fluence.

Calibration↗

In-phantom dosimetry and spectrometry of photoneutrons from an 18 MV linear accelerator.

A combination of three superheated drop detectors with different neutron energy responses was developed to evaluate dose-equivalent and energy distributions of photoneutrons in a phantom irradiated by radiotherapy high-energy x-ray beams. One of the three detectors measures the total neutron dose equivalent and the other two measure the contributions from fast neutrons above 1 and 5.5 MeV, respectively. In order to test the new method, the neutron field produced by the 10 cm X 10 cm x-ray beam of an 18 MV radiotherapy accelerator was studied. Measurements were performed inside a tissue-equivalent liquid phantom, at depths of 1, 5, 10 and 15 cm and at lateral distances of 0, 10, and 20 cm from the central axis. These data were used to calculate the average integral dose to the radiotherapy patient from direct neutrons as well as from neutrons transmitted through the accelerator head. The characteristics of the dosimeters were confirmed by results in excellent agreement with those of prior studies. Track etch detectors were also used and provided an independent verification of the validity of this new technique. Within the primary beam, we measured a neutron entrance dose equivalent of 4.5 mSv per Gy of photons. It was observed that fast neutrons above 1 MeV deliver most of the total neutron dose along the beam axis. Their relative contribution increases with depth, from about 60% at the entrance to over 90% at a depth of 10 cm. Thus, the average energy increases with depth in the phantom as neutron spectra harden.

Biophysical Phenomena↗

Dosimetry of low-energy neutrons using low-pressure proportional counters.

Measurements in nearly monoenergetic beams of 144, 24.5, and 2 keV neutrons and of thermal neutrons have been performed with low-pressure proportional counters. The suitability of a tissue-equivalent proportional counter (TEPC) for dosimetry of low-energy neutrons has been investigated. In contrast to higher neutron energies, the modification of the primary radiation field by the detector wall and the contribution of secondaries produced in the gas are significant. These effects have been investigated by additional measurements with a carbon-walled proportional counter. The various physical processes of neutron interaction with wall and gas of the TEPC have been analyzed, and absorbed dose, kerma, and kerma contributions from the various processes are presented. In addition, dose contributions from contaminating neutrons and photons have been obtained for the calibration fields used. The results have been related to neutron fluence. The comparison with tabulated kerma factors shows excellent agreement, indicating the suitability of the TEPC method for dosimetry of low-energy neutrons.

Energy Transfer↗