PubMed HealthSearch

Biomedical subjects

W G Hawkins

Publications and source records attributed to W G Hawkins.

8 recordsLinked to original sources

Validation of the circular harmonic transform (CHT) algorithm for quantitative SPECT.

The purpose of this study was to validate the use of the circular harmonic transform (CHT) algorithm for quantitative single-photon emission computed tomography (SPECT) with isotopes technetium-99m (99mTc) and indium-111 (111In) under clinically relevant conditions. Phantom studies were the principal tools used. Volumes of fillable organs within a tissue-equivalent anthropomorphic phantom were determined over a wide range (145-1960 ml) to within 6% by using a thresholding technique. Additionally, phantom studies with nonuniform activity distributions were made. These included a background of activity and hot as well as cold lesions. The hot lesion was computed to within 12% (111In) and 7.7% (99mTc), and contrast in the cold lesion was approximately 70% for both isotopes. The CHT algorithm incorporates the energy-distance relation (EDR) which minimizes the degrading effects of attenuation, scatter, collimator blur and poor statistics.

Algorithms

Quantitative SPECT for indium-111-labeled antibodies in the livers of beagle dogs.

Results are presented for SPECT computations of liver volumes and 111In-labeled antibody activities in the livers of eight normal beagle dogs. Administered activities ranged from 1 to 2 mCi. SPECT studies were acquired 1 day postinjection using a rotating gamma camera system with elliptical orbits in a 360-degree rotation (128 views, 15 sec/view, 64 x 64 matrices). Uniformity-corrected images were reconstructed by use of the circular harmonic transform algorithm with computer software developed in-house. Liver volumes and activities were computed from transverse slices, 1 pixel (6.25 mm) in thickness. Comparison of SPECT and autopsy data demonstrated that absolute values of percent differences between measured and computed liver volumes ranged from 1.0% to 7.2%. Absolute values of percent differences between autopsy data and computed 111In activities in the liver ranged from 2.3% to 7.5%. These results suggest that quantitative SPECT has the potential of becoming an important tool in clinical trials for determining activities and localization volumes of radiolabeled antibodies directly from radionuclide images.

Animals

Dosimetry and treatment planning for 90Y-labeled antiferritin in hepatoma.

Radiation absorbed-dose estimates and treatment planning are reported for 11 patients with hepatoma who were administered 90Y-labeled polyclonal antiferritin IgG for therapy in a Phase 1-2 trial. Dosimetric studies included quantitation of the localization and clearance of 111In-labeled antiferritin IgG in tumor and normal tissues and computer-assisted tumor and normal liver volumetrics from X ray CT scans. For the group of patients studied, hepatoma volumes at the time of treatment ranged from 135 to 3442 cm3. Quantitative 111In antiferritin imaging prior to and following 600 or 900 cGy of external-beam irradiation of the primary tumor demonstrated that tumor uptake increased 1.1 to 5.8-fold (mean 2.8) following external beam. In contrast, changes in uptake of radiolabeled antiferritin in normal liver ranged from 0.35 to 2.1-fold (mean 0.93) after external irradiation. Administered activities of 90Y antiferritin ranged from 8 to 37 mCi and were dependent on tumor volume and tumor localization of radiolabeled antiferritin. Following external-beam irradiation, tumor dose rates achieved with 90Y antiferritin ranged from 10 to 20 cGy/hr and normal liver dose rates from 1.1 to 5.7 cGy/h. The corresponding absorbed dose in hepatomas ranged from 900 to 2150 cGy and in normal liver from 80 to 650 cGy. After external-beam irradiation, tumor and normal liver uptake of 90Y antiferritin was consistent with that of 131I antiferritin.

Antibodies

CT volumetrics of primary liver cancers.

A new computer algorithm is described for liver and tumor volume determinations for patients with hepatoma and primary hepatic cholangiocarcinoma. The algorithm is based on global histograms of CT numbers of the liver and primary liver cancers. The algorithm includes computer-assisted definition of the liver boundary in each CT slice. Liver and tumor volumes of 10 patients calculated by the histogram method were compared with volumes obtained from CT slices that were manually contoured by experienced observers. A correlation coefficient of 0.995 was determined for these two methods of volume computations. Mean values of the differences in volumes obtained by the two methods were 6.7 and 8.0% for the liver and tumor, respectively. The computer algorithm was tested on CT scans for an additional 46 patients by highlighting regions corresponding to normal liver and tumor tissues in each CT slice and determined to be accurate by experienced observers. The computer software is being used clinically to assess tumor response in a new treatment program for primary liver cancers that includes radiolabeled antibodies.

Adenoma, Bile Duct

Effective atomic numbers for low-energy total photon interactions in human tissues.

A new method is introduced in which the total photon interaction cross sections per electron of human tissues are used to define effective atomic numbers for blood, bone, brain, fat, heart, kidney, liver, lung, muscle, ovary, pancreas, spleen, and water. These effective atomic numbers are equal within 4% from 10 to 200 keV in each soft tissue, whereas for bones of different chemical compositions the variation ranges from 2.86% to 5.03%. This effective atomic number definition is less energy dependent than a previous definition based on the total photon interaction cross section per atom averaged over all elements in the tissue, from which the computed effective atomic numbers varied by as much as 50% (in bone) as a function of photon energy over the energy range from 10 to 200 keV.

Adipose Tissue

The effect of intrinsic attenuation correction methods on the stationarity of the 3-D modulation transfer function of SPECT.

The application of stationary restoration techniques to SPECT images assumes that the modulation transfer function (MTF) of the imaging system is shift invariant. It was hypothesized that using intrinsic attenuation correction (i.e., methods which explicitly invert the exponential radon transform) would yield a three-dimensional (3-D) MTF which varies less with position within the transverse slices than the combined conjugate view two-dimensional (2-D) MTF varies with depth. Thus the assumption of shift invariance would become less of an approximation for 3-D post- than for 2-D pre-reconstruction restoration filtering. SPECT acquisitions were obtained from point sources located at various positions in three differently shaped, water-filled phantoms. The data were reconstructed with intrinsic attenuation correction, and 3-D MTFs were calculated. Four different intrinsic attenuation correction methods were compared: (1) exponentially weighted backprojection, (2) a modified exponentially weighted backprojection as described by Tanaka et al. [Phys. Med. Biol. 29, 1489-1500 (1984)], (3) a Fourier domain technique as described by Bellini et al. [IEEE Trans. ASSP 27, 213-218 (1979)], and (4) the circular harmonic transform (CHT) method as described by Hawkins et al. [IEEE Trans. Med. Imag. 7, 135-148 (1988)]. The dependence of the 3-D MTF obtained with these methods, on point source location within an attenuator, and on shape of the attenuator, was studied. These 3-D MTFs were compared to: (1) those MTFs obtained with no attenuation correction, and (2) the depth dependence of the arithmetic mean combined conjugate view 2-D MTFs.(ABSTRACT TRUNCATED AT 250 WORDS)

Humans