Imaging performance of amorphous selenium based flat-panel detectors for digital mammography: characterization of a small area prototype detector.

Our work is to investigate and understand the factors affecting the imaging performance of amorphous selenium (a-Se) flat-panel detectors for digital mammography. Both theoretical and experimental methods were developed to investigate the spatial frequency dependent detective quantum efficiency [DQE(f)] of a-Se flat-panel detectors for digital mammography. Since the K edge of a-Se is 12.66 keV and within the energy range of a mammographic spectrum, a theoretical model was developed based on cascaded linear system analysis with parallel processes to take into account the effect of K fluorescence on the modulation transfer function (MTF), noise power spectrum (NPS), and DQE(f) of the detector. This model was used to understand the performance of a small-area prototype detector with 85 microm pixel size. The presampling MTF, NPS, and DQE(f) of the prototype were measured, and compared to the theoretical calculation of the model. The calculation showed that K fluorescence accounted for a 15% reduction in the MTF at the Nyquist frequency (fNy) of the prototype detector, and the NPS at fNy was reduced to 89% of that at zero spatial frequency. The measurement of presampling MTF of the prototype detector revealed an additional source of blurring, which was attributed to charge trapping in the blocking layer at the interface between a-Se and the active matrix. This introduced a drop in both presampling MTF and NPS at high spatial frequency, and reduced aliasing in the NPS. As a result, the DQE(f) of the prototype detector at fNy approached 40% of that at zero spatial frequency. The measured and calculated DQE(f) using the linear system model have reasonable agreement, indicating that the factors controlling image quality in a-Se based mammographic detectors are fully understood, and the model can be used to further optimize detector imaging performance.

Artifacts↗

Effects of characteristic x rays on the noise power spectra and detective quantum efficiency of photoconductive x-ray detectors.

The effects of K fluorescence on the imaging performance of photoconductor-based x-ray imaging systems are investigated. A cascaded linear systems model was developed, where a parallel cascaded process was implemented to take into account the effect of K-fluorescence reabsorption on the modulation transfer function (MTF), noise power spectrum (NPS), and the spatial frequency dependent detective quantum efficiency [DQE(f)] of an imaging system. The investigation was focused on amorphous selenium (a-Se), which is the most highly developed photoconductor material for x-ray imaging. The results were compared to those obtained with Monte Carlo simulation using the same imaging condition and detector parameters, so that the validity of the cascaded linear system model could be confirmed. Our results revealed that K-fluorescence reabsorption in a-Se is responsible for a 18% drop in NPS at high spatial frequencies with an incident x-ray photon energy of E=20 keV (which is just above the K edge of 12.5 keV). When E increases to 60 keV, the effects of K-fluorescence reabsorption on NPS decrease to approximately 12% at high spatial frequencies. Because the high frequency drop is present in both MTF and NPS, the effect of K fluorescence on DQE(f) is minimal, especially for E that is much higher than the K edge. We also applied the cascaded linear system model to a newly developed compound photoconductor, lead iodide (PbI2), and found that at 60 keV there is a high frequency drop in NPS of 19%. The calculated NPS were compared to previously published measurements of PbI2 detectors.

Diagnostic Imaging↗

Digital x-ray imaging using amorphous selenium: reduction of aliasing.

Alias reduction is analyzed with the concept of an equivalent presampling filter, and a mathematical approach is established to find the equivalent presampling filter corresponding to specific digital image processing algorithms. The effects of different sampling period T and sampling aperture tau on aliasing artifacts and on the resultant detective quantum efficiency (DQE) for a self-scanned, flat-panel, amorphous selenium detector are obtained. Different effective apertures can be obtained from the same detector by averaging signals over adjacent pixels. It is shown that adding outputs from M adjacent pixels is equivalent to introducing an equivalent presampling filter with special properties. Appropriate selection of the averaging parameters (M and weights) is shown to reduce the aliasing artifact in the resultant image. The effect of incomplete charge collection due to geometrical effects (fill factor) is examined. It is shown that a large fill factor is desirable for aliasing reduction. The relationship between a digital filter applied to the sampled signal and its equivalent presampling analog filter is also established. Analytical formulas for the sampled spectrum of white signal and for the sampled power spectrum of white noise are obtained for aperture functions with a spatially uniform response. These formulas take into accounts aliasing artifacts, signal correlation and aperture function response, and demonstrate the dependence of sampled spectra on T and tau. With these formulas the detective quantum efficiency DQE is derived. It is shown that the resultant DQE depends only on the fill factor and the size of readout electrode tau 0, but is completely independent of the degree or type of pixel averaging. That is, even though the pixel averaging method reduces aliasing it leaves DQE (omega) unchanged. When significant amplifier noise is present the DQE obtained with the pixel averaging method can be better than those obtained with an analog presampling filter. Finally, it is pointed out that the requirement of reducing aliasing artifacts conflicts with other requirements for a detector such as maximizing modulation transfer function (MTF). A careful and practical compromise has to be made by a detector designer in choosing the extent to which the aliasing artifacts are eliminated.

Algorithms↗