PubMed Health⌕ Search

Biomedical subjects

W Goessler

Publications and source records attributed to W Goessler.

At least 19 recordsLinked to original sources

Adult-type hypolactasia and calcium availability: decreased calcium intake or impaired calcium absorption?

UNLABELLED: Adult-type hypolactasia, as mediated by a widespread genetic predisposition, not only reduces calcium intake but also calcium absorption in the presence of high amounts of lactose and may, therefore, promote osteoporosis. A lactose-reduced diet and lactose-free calcium supplements may reverse this imbalance. INTRODUCTION AND HYPOTHESIS: Adult-type hypolactasia (HL) defined by the LCT(-13910) polymorphism may reduce calcium intake by reducing dairy consumption and, therefore, promote osteoporosis. This study aimed to evaluate whether lactose also decreases intestinal calcium absorption in subjects with HL and whether lactose-reduced diet and lactose-free calcium supplementation as recommended could maintain bone mineral density (BMD). METHODS: Based on LCT genotyping, 73 postmenopausal women with and without HL underwent a conventional H(2) breath test with a concomitant oral strontium absorption test lasting 150 minutes, which closely reflects intestinal calcium absorption. In addition, we compared bone-specific laboratory parameters, lumbar and femoral BMD, and spinal radiographs to a similar bone assessment 5 years earlier. RESULTS: LCT genotyping and functional lactose malabsorption tests were highly correlated. Dairy product consumption was reduced by 80% in HL individuals. During concomitant lactose application, mean strontium absorption was blunted by 54% in HL subjects after 150 minutes (1272 +/- 629 microg/L vs. 2020 +/- 1130 microg/L in lactose tolerant subjects, p=0.001). Nevertheless, BMD in HL subjects remained stable with lactose-free calcium supplements during the observation period. CONCLUSION: Both decreased calcium intake as well as lactose-associated impaired calcium absorption may predispose subjects with HL to osteoporosis. Lactose-free calcium supplementation may help to maintain BMD in HL subjects.

Absorption↗

Accurate quantification and transformation of arsenic compounds during wet ashing with nitric acid and microwave assisted heating.

Arsenous acid, dimethylarsinic acid (DMA), methylarsonic acid (MA), arsenic acid, arsenobetaine bromide (AB), trimethylarsine oxide (TMAO), arsenocholine iodide (AC), and tetramethylarsonium iodide (TETRA) were heated in a microwave autoclave with nitric acid to 100-300 degrees C. The arsenic compounds in the digests were separated with anion- and cation-exchange chromatography and determined with an inductively coupled plasma mass spectrometer as arsenic-specific detector. Arsenous acid was completely oxidized to arsenic acid at 100 degrees C. For a complete oxidation of MA and DMA to arsenic acid temperatures > 220 degrees C and > 280 degrees C were necessary. AB decomposed to arsenic acid via TMAO. Complete conversion was only obtained after heating the sample for 90 min to 300 degrees C. For a complete conversion of TMAO similar harsh conditions were necessary. AC was already substantially degraded to TMAO, TETRA and two unknown compounds at 100 degrees C. The unknown arsenic compounds were found only in the digests up to 160 degrees C. Quantitative conversion of AC to arsenic acid went also via TMAO. At temperatures above 220 degrees C TETRA started to convert to TMAO, which then was further converted to arsenic acid. To investigate whether the results obtained for the arsenic standards are transferable to real samples, the certified reference material DORM-2 was also heated in nitric acid with variable digestion temperatures and times. For an almost complete conversion of the AB present in DORM-2 90 min at 300 degrees C were necessary. Total organic carbon (TOC) was less < 0.2% when DORM-2 was heated at temperatures > or = 260 degrees C for 60 min. UV photo-oxidation of DORM-2 was investigated as an alternative sample decomposition. Only 6% of AB was converted to arsenic acid when DORM-2 was irradiated for 2 h at 1000 W. In contrast to microwave heating substantial amounts of MA were observed as degradation product.

Journal Article↗

Occurrence of organo-arsenicals in jellyfishes and their mucus.

Water-soluble arsenic compound fractions were extracted from seven species of jellyfishes and subjected to analysis by high-performance liquid chromatography-inductively coupled plasma mass spectrometry (HPLC-ICP-MS) for arsenicals. A low content of arsenic was found to be the characteristic of jellyfish. Arsenobetaine (AB) was the major arsenic compound without exception in the tissues of the jellyfish species and mucus-blobs collected from some of them. Although the arsenic content in Beroe cucumis, which preys on Bolinopsis mikado, was more than 13 times that in B. mikado, the chromatograms of these two species were similar in the distribution pattern of arsenicals. The nine species of jellyfishes including two species treated in the previous paper can be classified into arsenocholine (AC)-rich and AC-poor species. Jellyfishes belonging to Semaostamae were classified as AC-rich species.

Animals↗

Arsenic biotransformation by the brown macroalga, Fucus serratus.

The brown alga Fucus serratus was maintained in aquaria with added arsenate (0, 20, 50, and 100 microg As/L, four individuals per treatment) for up to 19 weeks. Biotransformation of arsenic by Fucus was monitored by high-performance liquid chromatography/inductively coupled plasma mass spectrometry and liquid chromatography/electrospray mass spectrometry analysis of aqueous extracts of algal frond tips removed periodically throughout the experiment. Major arsenic species monitored were arsenate, arsenite, methylarsonate, dimethylarsinate, and the four arsenosugars 1 to 4 found naturally in Fucus. Algae accumulated arsenate readily and transformed it into several arsenic compounds depending on the exposure concentration. At 100 microg As/L, the major metabolite was arsenite with smaller quantities of methylarsonate and dimethylarsinate, but only traces of arsenosugars were formed. In contrast, the 20-microg-As/L group accumulated only small quantities of arsenite and methylarsonate, while dimethylarsinate and arsenosugars were major arsenic metabolites. At 50 microg As/L exposure, algae had significant quantities of all arsenic metabolites monitored. Arsenate was toxic to the algae at 100 microg As/L but had no obvious detrimental effect at 20 microg As/L. The data are consistent with a process of arsenate detoxification by reduction and alkylation; at higher exposures, however, the alkylation processes become saturated, leading to an accumulation of arsenite and subsequent toxicity.

Alkylation↗

Role of bound zinc in dimer stabilization but not enzyme activity of neuronal nitric-oxide synthase.

Nitric-oxide synthases (NOS) are homodimeric proteins and can form an intersubunit Zn(4S) cluster. We have measured zinc bound to NOS purified from pig brain (0.6 mol/mol of NOS) and baculovirus-expressed rat neuronal NOS (nNOS) (0.49 +/- 0.13 mol/mol of NOS), by on-line gel-filtration/inductively coupled plasma mass spectrometry. Cobalt, manganese, molybdenum, nickel, and vanadium were all undetectable. Baculovirus-expressed nNOS also bound up to 2. 00 +/- 0.58 mol of copper/mol of NOS. Diethylenetriaminepentaacetic acid (DTPA) reduced the bound zinc to 0.28 +/- 0.07 and the copper to 0.97 +/- 0.24 mol/mol of NOS. Desalting of samples into thiol-free buffer did not affect the zinc content but completely eliminated the bound copper (</=0.02 mol/mol of NOS). Most (> or =75%) of the bound zinc was released from baculovirus-expressed rat nNOS by p-chloromercuriphenylsulfonic acid (PMPS). PMPS-treated nNOS was strongly (90 +/- 5%) inactivated. To isolate functional effects of zinc release from other effects of PMPS, PMPS-substituted thiols were unblocked by excess reduced thiol in the presence of DTPA, which hindered reincorporation of zinc. The resulting enzyme contained 0.12 +/- 0.05 mol of zinc but had a specific activity of 426 +/- 46 nmol of citrulline.mg(-1).min(-1), corresponding to 93 +/- 10% of non-PMPS-treated controls. PMPS also caused dissociation of nNOS dimers under native conditions, an effect that was blocked by the pteridine cofactor tetrahydrobiopterin (H(4)biopterin). H(4)biopterin did not affect zinc release. Even in the presence of H(4)biopterin, PMPS prevented conversion of NOS dimers to an SDS-resistant form. We conclude that zinc binding is a prerequisite for formation of SDS-resistant NOS dimers but is not essential for catalysis.

4-Chloromercuribenzenesulfonate↗

Mercury determination with ICP-MS: signal suppression by acids.

When mercury is quantified by ICP-MS under routine conditions (external calibration) in reference materials, which require mineralization with nitric acid, the experimental concentrations are almost always unacceptably low in comparison to certified values. Sorption of mercury on the Teflon surfaces of the digestion vessels, changes in the viscosity of the aspirated solutions, in the efficiency of the nebulization, in the aerosol transport, and memory effects cannot be responsible for the low results. The intensity of a mercury signal is strongly dependent on the concentration of nitric acid (and other mineral acids) in the measured solutions. Correct results for mercury in the SRM GBW-90101 (Chinese human hair; 2.16+/-0.21 mg Hg/kg certified) can only be obtained, when the solutions, with which the external calibration curves were established, have exactly the same nitric acid concentration as the aspirated digests (2.03+/-0.01 mg Hg/kg; n = 5), when mercury is determined by the standard addition method (2.10+/-0.01 mg Hg/kg; n = 5), or when the experimental mercury concentration obtained at a nitric acid concentration in the digest, different from the concentration in the external calibration solutions, is corrected mathematically based on a pre-established function [Hg2+] = f [HNO3]. The concentrations found by this mathematically based correction 2.04+/-0.01 mg Hg/kg (n = 5) is in good agreement with the values obtained by acid matched calibration or by the standard addition method. For practical work with large numbers of samples the mathematical correction appears to be the method of choice. For occasional mercury determinations, the standard addition method seems to be the most practicable.

China↗

Microwave digestion of "residual fuel oil" (NIST SRM 1634b) for the determination of trace elements by inductively coupled plasma-mass spectrometry.

A microwave procedure for the digestion of the NIST 1634b reference material "residual fuel oil" in closed pressurized vessels was developed in an attempt to facilitate routine analysis and obtain reproducible conditions or comparable results. The influence of sample size, reagent composition and volume, microwave power, and duration of heating on the digestion procedure was studied. Pressure and temperature inside the reaction vessels were monitored to determine the progression of the reaction and to develop optimal conditions. A nine-step heating program requiring 36.5 min with microwave power not exceeding 450 W in the pulsed mode was found suitable for the digestion of approximately 250 mg fuel oil with a mixture of nitric acid (5.0 mL) and hydrogen peroxide (2.0 mL). The reproducibility of microwave power was determined in terms of the relative standard deviations (n = 3) for temperature (2.7%) and pressure (4.9%) data. The vapor pressures obtained with 5.0 mL Milli-Q water (heated) in an 80-mL digestion vessel showed good agreement with literature data. The excess acid in the resulting digests was removed by evaporation and the concentrations of 24 elements (Ag, Al, As, Ba, Bi, Ca, Cd, Co, Cr, Cu, Fe, Hg, Mg, Mo, Ni, Pb, Sb, Sn, Sr, Ti, Tl, V, U, and Zn) were determined in the diluted digests by inductively coupled plasma mass spectrometry (ICP-MS). The experimental results were in good agreement with the certified and recommended concentrations for eight elements (Al, As, Co, Cr, Ni, Pb, V, Zn) in solutions obtained after one digestion step. An additional digestion step, consisting of intermediate cooling and venting stages, was required for the accurate determination of Fe. No agreement was reached for Ca and Ba even after two-step digestion. The proposed method of digestion provided precise results with relative standard deviations generally less than 5% for most of the elements determined.

Journal Article↗

Determination of 'arsenosugars' in algae with anion-exchange chromatography and an inductively coupled plasma mass spectrometer as element-specific detector.

The retention behavior of four naturally occurring dimethylarsinoylribosides with -CH2-CHOH-CH2X (X = OH, HO3POCH2CHOHCH2OH, SO3H, OSO3H) as aglycones, of arsenous acid, arsenic acid, methylarsonic acid, and dimethylarsinic acid was investigated on a Hamilton PRP-X100 anion-exchange column with aqueous solutions of ammonium dihydrogen phosphate (20 mmol/L) in the pH range of 3.8-9.0 as mobile phase. A HP 4500 inductively coupled plasma mass spectrometer (ICP-MS) served as arsenic-specific detector. The influence of pH, temperature, and the concentration of methanol in the mobile phase on the retention times of these arsenic compounds was explored. An aqueous 20 mM ammonium dihydrogen phosphate solution at pH 5.6 at a column temperature of 40 degrees C was considered optimal as it allowed the separation of seven of the arsenic compounds within 16 min. Only arsenous acid and the ribose with the glycerol aglycone have overlapping signals with both migrating almost with the solvent front. At a concentration of 0.50 ng As mL(-1) the relative standard deviations (n = 3) of the signal areas of the eight arsenic compounds was in the range from 3.5 to 8.1%. The linear calibration curves (peak areas) from 0.5 to 10 ng/mL had correlation coefficients > 0.997. Extracts obtained from the brown algae Fucus spiralis and Halidrys siliquosa were chromatographed under the optimized conditions. Both species contained the sulfate riboside as the major arsenic compound (approximately 55% of total extractable arsenic) together with the sulfonate- and phosphate riboside. Arsenic acid was a significant constituent of Halidrys siliquosa (approximately 6.5%), but was not detected in Fucus spiralis.

Arsenicals↗

Selenium-enriched sprouts. A raw material for fortified cereal-based diets.

The selenium supply in almost all European countries, including Austria and Germany, is below the recommended daily intake. In these countries, selenium fortification of foods and the use of selenium supplements are quite popular to compensate for low Se intake from diets. In general, wheat (Triticum aestivum) is known to be a good source for bioavailable selenium, and many studies have been performed to enrich selenium in wheat by selenium fertilization of the soil. In the present work, the process of sprouting was investigated as an alternative to enrich selenium in wheat. Sprouting was chosen because it additionally improves the nutritional value of seeds, for example, by a higher vitamin content, a better quality of protein, and some other parameters. Wheat, alfalfa (Medicago sativa), and sunflower (Helianthus annuus) seeds were germinated for 5 and 7 days in solutions containing selenate. The selenium sensitivity of the sprouts was tested by measuring visible germination levels and seedling development. Uptake rates were studied by determination of total selenium using inductively coupled plasma mass spectrometry (ICP-MS). Metabolism of the absorbed selenium was analyzed by determination of selenium species in extracts of the sprouts using anion exchange HPLC coupled to ICP-MS. It was shown that sunflower sprouts were the most resistant and had the highest uptake rates (up to 900 mg/kg), but almost 100% of the selenium was extracted with water and found to be nonmetabolized selenate. Wheat and alfalfa were less resistant and enriched selenium up to concentrations of 100 and 150 mg of Se/kg of dry mass, respectively. The metabolism of the selenate was inversely related to the total uptake rates. At low Se enrichment (approximately 1-2 mg of Se/kg), <20% of the total selenium content within the sprouts remained as inorganic selenium, indicating a high metabolism rate. With increasing uptake the amount of selenate increased to approximately 40-50%. However, with the method used it is possible to produce sprouts containing certain amounts of selenium, which might provide substantial proportions of bioavailable selenium. In combination with the generally high nutritional value of sprouts, they might serve for production of improved cereal-based diets.

Edible Grain↗

Evaluation of cot mattress inner foam as a potential site for microbial generation of toxic gases.

Recent reports of biovolatilisation of phosphorus and antimony by anaerobic bacteria and of leaching of phosphorus and antimony fire-retardant additives from PVC cot mattress covers, indicate that the polyurethane inner-foam of cot mattresses could be a site for generation of toxic gases of group 15 elements. A toxic gas hypothesis for sudden infant death syndrome (SIDS) involving polyurethane foam of cot mattresses was proposed and tested experimentally. Levels of antimony, phosphorus, arsenic and bismuth were determined at four sites for 44 SIDS and 50 control (no death) cot mattress foams. There was no evidence to suggest that the levels of these elements in cot mattress foam have a causal relation to SIDS. Leaching of antimony trioxide from PVC mattress covers could account for detectable levels of this element in 52% of the cot mattress samples analysed. Volatile forms of antimony, phosphorus, arsenic and bismuth was not detected in the headspace of mixed or monoseptic cultures of anaerobic bacteria containing polyurethane foam. Past microbial activity had given rise to involatile methylated species of antimony in some of the cot mattress foams tested (61%, n = 24). Abiotic oxidation of biogenic trimethylantimony together with physical adsorption of methylantimony forms to the polyurethane foam matrix could account for the apparent absence of "escaped" volatile antimony species in culture headspaces of incubation vial. There was no evidence to suggest that levels of trimethylantimony or total methylantimony forms in cot mattress foams have a causal relation to SIDS.

Antimony↗

Pleural effusions and sera from patients with benign or malignant diseases.

In pleural effusions and sera from 66 patients copper and zinc were quantified by inductively coupled argon plasma-mass spectrometry after mineralizations in a closed-pressurized microwave unit with a mixture of concentrated nitric acid and 30% hydrogen peroxide. Total protein, pH, leukocyte count, lactate dehydrogenase, glucose, C-reactive protein, ceruloplasmin, and alpha1-antitrypsin were determined in many of the effusions. All but four effusions had concentrations of copper (range 58-1720 microg/kg) and zinc (range 27-1001 microg/kg) that were lower than the concentrations in the corresponding sera. Very high concentrations of zinc (1930-6470 microg/kg) were characteristic for thoracic empyemata. In the scatterplots of serum copper versus effusion copper, serum zinc versus effusion zinc, and serum copper/effusion copper versus serum zinc/effusion zinc no clearly delineated regions were noticeably useful for identifying malignant effusions. Similar plots of the concentrations of copper or zinc versus the eight clinical laboratory parameters or plots of clinical parameter versus clinical parameter failed to be of diagnostic value. Statistically highly significant correlations (p < or = 0.05, n > 45, r2 > 0.25) were observed for 9 of 28 pairs of the clinical parameters, for total protein and copper in the effusions and zinc in the effusions and for ceruloplasmin and copper in the effusions. Among the patients suffering from benign or malignant effusions, 52% had zinc concentrations in the sera below the low limit of the normal range (600 microg/kg). Supplementation of such patients with zinc should be considered.

Adolescent↗

Concentrations of copper, zinc, manganese, rubidium, and magnesium in thoracic empyemata and corresponding sera.

In this study, a number of selected trace elements and clinically relevant parameters were compared between thoracic empyemata and the corresponding sera for a better understanding of the trace element distribution between these two compartments. Serumempyema pairs were obtained from 13 patients and quantified for selected and essential trace elements, namely copper (Cu), zinc (Zn), manganese (Mn), rubidium (Rb), and magnesium (Mg), by inductively coupled plasma-mass spectrometry (ICP-MS). In addition, the concentrations of the following clinical laboratory parameters were analyzed by standard methods: total protein, leukocyte count, lactate dehydrogenase, glucose, pH, and the C-reactive protein. Individual concentrations of the elements determined in the empyemata were frequently higher than in pleural effusions of any other benign or malignant condition except for Cu. Serum Cu exceeded the normal range (600-1400 microg/kg) in 6 out of 13 patients (median 1410 microg/kg). In the empyemata, Zn concentrations (median 2000 microg/kg) were characteristically higher than in the sera (median 450 microg/kg) and exceeded the upper limit for serum (1200 microg/kg) in 8 of the 13 patients. Manganese concentrations in the empyemata (median 2.7 microg/kg) were also higher compared to corresponding sera, although they stayed within the limits considered normal for serum of healthy adults (upper limit 2.9 microg/kg). Rubidium was also moderately higher in most empyemata (median 290 microg/kg) and exceeded the upper limit for serum (560 microg/kg) in two patients. The median concentration of the essential element magnesium was higher in the empyemata (23 mg/kg) than in the sera (21 mg/kg). However, all serum Mg concentrations except three remained within the normal range (17-22 mg/kg). Removal of large amounts of empyematous fluid may deprive the body of trace elements and can cause suboptimal or deficient trace element status and homeostasis. Recuperation will be accelerated by compensatory supplementation of trace elements. Therefore, selective medication with adequate trace element compounds in patients with thoracic empyema can be generally recommended for zinc. The other elements need not necessarily be monitored or substituted, because of their stable concentrations in the serum. Rb may have a biological impact, but deficiency symptoms in man are not clearly defined.

Aged↗

Characterization of recombinant human endothelial nitric-oxide synthase purified from the yeast Pichia pastoris.

Human endothelial nitric-oxide synthase (eNOS) was expressed in the methylotrophic yeast Pichia pastoris, making use of the highly inducible alcohol oxidase promoter. The recombinant protein constituted approximately 3% of total protein and was largely soluble (>75%). About 1 mg of purified eNOS was obtained from 100-ml yeast cell cultures by affinity chromatography of crude cell supernatants. The purified enzyme had a V(max) of 192 +/- 18 nmol of L-citrulline x mg(-1) x min(-1), had a K(m) for L-arginine of 3.9 +/- 0.2 microM, and showed an absolute requirement for tetrahydrobiopterin (H(4)biopterin). NADPH oxidase activity was 136 +/- 9 and 342 +/- 24 nmol x mg(-1) x min(-1) in the absence and presence of 0.1 mM L-arginine, respectively, and not affected by H(4)biopterin. The protein contained 0.56 +/- 0.06 equivalents of FAD and 0.79 +/- 0.08 equivalents of FMN. On-line gel filtration/inductively coupled plasma mass spectrometry analysis confirmed that both iron (0.80 +/- 0.09 mol/subunit) and zinc (0.43 +/- 0.03 mol/subunit) were bound to the enzyme. Graphite furnace-atomic absorption spectroscopy yielded a value for bound iron of 0.84 +/- 0.04 mol/subunit. The absorbance of the enzyme at 398 nm implied a heme content of 0.85 +/- 0.09 mol/subunit, and the high pressure liquid chromatography heme assay gave an estimate of 0.71 +/- 0.02 mol heme/subunit. Gel permeation chromatography yielded one single peak with a Stokes radius of 6.62 +/- 0.7 nm, indicating that the native protein is dimeric. Upon low temperature gel electrophoresis the untreated protein appeared mainly as a monomer (88 +/- 3%), but pretreatment with H(4)biopterin and L-arginine led to a pronounced shift toward dimers (77 +/- 4%). Thus, in contrast to bovine eNOS (List, B. M., Klösch, B., Völker, C., Gorren, A. C. F., Sessa, W. C., Werner, E. R., Kukovetz, W. R., Schmidt, K., and Mayer, B. (1997) Biochem. J. 323, 159-165; Rodriguez-Crespo, I., Gerber, N. C., and Ortiz de Montellano, P. R. (1996) J. Biol. Chem. 271, 11462-11467), the human eNOS appears to be markedly stabilized by H(4)biopterin.

Animals↗

Determination of bromide, bromate and other anions with ion chromatography and an inductively coupled plasma mass spectrometer as element-specific detector.

An implementation of the Dionex IonPac AS12A analytical column with an element-specific ICP-MS detection is described for the simultaneous determination of halogen and oxyhalogen anions, sulfate, phosphate, selenite, selenate and arsenate. The chromatographic separation was achieved in less than 4 min with an aqueous 11 mM (NH4)2CO3 (pH 11.2, adjusted with aqueous ammonia) as eluent. Special emphasis was given to optimize the ICP-MS detection conditions for the reliable detection (RSD<5%) of bromate and bromide at a bromine concentration level of 1.0 microg l(-1) with 50 microl sample injection volume. In order to achieve the highest detector response for bromine species an ultrasonic nebulizer equipped with a membrane desolvator had to be employed. The detection limits (S/N=3, sample injection volume 50 microl) obtained with the IC-ICP-MS after the optimization were 0.67 microg l(-1) for BrO3-, 0.47 microg l(-1) for Br-, 69 microg l(-1) for ClO2-, 4 microg l(-1) for Cl-, 47 microg l(-1) for ClO3-, 13 microg l(-1) for SO4(2-), 36 microg l(-1) for PO4(3-), 0.4 microg l(-1) for SeO3(2-), 0.3 microg l(-1) for SeO4(2-), and 0.4 microg l(-1) for AsO4(3-).

Anions↗

Uptake of arsenic-betaines by the mussel Mytilus edulis.

Mussels (Mytilus edulis) were exposed to trimethyl(carboxymethyl)arsonium bromide (arsenobetaine, C-1 betaine), trimethyl(2-carboxyethyl)arsonium bromide (C-2 betaine), or trimethyl(3-carboxypropyl)arsonium bromide (C-3 betaine). Arsenic was accumulated by the mussels in all cases but the efficiency of uptake decreased with the number of methylene units in the carboxyalkyl group. Arsenobetaine (C-1 betaine) was the most readily accumulated, followed by the C-2 betaine (70% as efficient as arsenobetaine) and the C-3 betaine (approximately 7%). Chromatographic analysis (HPLC-ICPMS) of extracts of the mussels demonstrated that the arsenic compounds were accumulated unchanged. A 46-day depuration period which followed exposure did not significantly reduce the arsenic concentration in any of the three groups. Comparison with previous data on accumulation of arsenic compounds by M. edulis indicates that uptake may be influenced by the presence of a quaternary arsonium group and the zwitterionic nature of the arsenic-betaines.

Animals↗

Milk consumption, smoking and lead concentration in human hair.

Trace elements in hair samples were examined in 79 medical and sports students in Vienna and 77 biology students in Rome (ages 19-31 years). Lead concentration was determined by inductively coupled plasma mass spectrometry. The effect of smoking on lead levels is confirmed. Those who consume milk and dairy products daily show a lower lead concentration than those who consume them occasionally, both overall and in smokers and non-smokers. The effects of milk consumption and smoking appear to be independent. It seems that smokers may not enjoy the protective effect of milk consumption to the same extent as non smokers.

Adult↗

Determination of selenium compounds by HPLC with ICP-MS or FAAS as selenium-specific detector.

A speciation method was developed for selenious acid, selenic acid, trimethylselenonium ion (TMSe) and selenomethionine (SeMet). Separation of the four selenium species was achieved by HPLC on an ESA Anion III anion-exchange column using aqueous mobile phase of 5.5 mmol/L ammonium citrate at pH 5.5 with a flow rate of 1.5 mL/min. Under the optimal conditions, the four selenium species were separated within 8 minutes. On-line selenium-specific detection was carried out with an inductively coupled plasma mass spectrometer (ICP-MS) or a flame atomic absorption spectrometer (FAAS). The detection limits of HPLC-FAAS were approximately rho(Se) = 1 mg/L for each compound (100 microL injection). To increase the nebulization efficiency of the ICP-MS, the Meinhard concentric nebulizer was replaced by an ultrasonic nebulizer (USN). The ICP-MS signal intensity was increased by a factor of 7 for selenious acid and 24 to 31 for TMSe, SeMet and selenic acid with the USN compared to that with the Meinhard nebulizer. The detection limits of the HPLC-USN-ICP-MS were rho(Se) = 0.08 microgram/L for TMSe, rho(Se) = 0.34 microgram/L for selenious acid, rho(Se) = 0.18 microgram/L for SeMet and rho(Se) = 0.07 microgram/L for selenic acid.

Chromatography, High Pressure Liquid↗